relay SSANGYONG RODIUS 2006 User Guide
[x] Cancel search | Manufacturer: SSANGYONG, Model Year: 2006, Model line: RODIUS, Model: SSANGYONG RODIUS 2006Pages: 444, PDF Size: 56.32 MB
Page 180 of 444

0-7
STICS
RODIUS 2007.07
8710-01
3. FUNCTIONS OF RK STICS
1) Wiper Control
(1) Wiper MIST and Washer Coupled Wiper
The wiper relay is turned on 0.3 seconds (T1) after turning “ON” the washer switch for
0.2 ~ 0.59 seconds (T2) with the ignition key “ON”, and it is turned off when the
parking terminal is turned off. 1.
The wiper relay is turned on 0.3 seconds (T1) after turning “ON” the washer switch
over 0.6 seconds (T2) with the ignition key “ON”, and it is turned on three times
immediately after turning off the washer switch. 2.
Page 183 of 444

0-10
RODIUS 2007.07
8710-01
STICS
Rain sensing operation point ▶
The wiper relay is turned on and the wiper motor runs one cycle when the ignition key is
turned to “ON” position (while the wiper switch is in “AUTO” position).
The wiper relay (LO) is turned on and the wiper motor runs one cycle when changing the
wiper switch to “AUTO” position from any other positions (while the ignition key is in
“ON” position). When the wiper switch is turned to “AUTO” position again from other
positions, the system drives the wiper relay (LO) to run the wiper motor one cycle only when
the rain sensor detects the “Rain Detected” signal. 1)
2)
Rain sensing sensitivity control ▶
The wiper relay is turned on and the wiper motor runs one cycle when the volume sensitivity is
increased (ex: from 0 to 1) (while the ignition key is in “ON” position, the wiper switch is
in “AUTO” position, and the wiper motor is in “Parked” position). However, the wiper
motor can be operated only when the rain sensor detects the “Rain Detected” signal.
* If the volume sensitivity is changed more than 2 stages within 2 seconds, the wiper motor runs
only one cycle.
Page 185 of 444

0-12
RODIUS 2007.07
8710-01
STICS
Defective rain sensor ▶
The wiper relay (LO) is turned on and the wiper motor runs one cycle when the wipe
r
sensitivity is changed to 2 from 3 during receiving the malfunction signal (1) from the rain
sensor (while the ignition key is in “ON” position and the wiper switch is in “AUTO”
position). 1)
The wiper relay (LO) is turned on and the wiper motor runs one cycle when the wiper
sensitivity is changed to 3 from 4 during receiving the malfunction signal (2) from the rain
sensor (while the ignition key is in “ON” position and the wiper switch is in “AUTO”
position). 2)
Page 186 of 444

0-13
STICS
RODIUS 2007.07
8710-01
The wiper relay (LO) is turned on and the wiper motor runs one cycle when the wiper
sensitivity is changed to 2 from 1 during receiving the malfunction signal (3) from the rain
sensor (while the ignition key is in “ON” position and the wiper switch is in “AUTO”
position). Also, the wiper relay (LO) is turned on and the wiper motor runs one cycle when
the wiper sensitivity is changed to 2 from 1 during receiving the ground fixed or IGN fixed
signal from the rain sensor. 3)
Page 188 of 444

0-15
STICS
RODIUS 2007.07
8710-01
The wiper relay continues to output when the parking terminal is fixed at the ground or
IGN while the wiper relay is “ON” (INT switch = ON or Washer switch = ON) (The
output stops immediately after turning off the switch) - (1) Wiper MIST and washer coupled wiper
When turning on the washer switch while the wiper relay is operating. 1)
If the wiper relay “ON” request time is shorter than the remained “ON” time, it is
disregarded. -
(2) Speed sensitive INT (intermittent) wiper
The wiper relay continues to output for remaining “ON” time even when the INT
switch is turned off.
IGN 2 switch “ON”, INT switch “OFF”: resume the intermittent time when turning
“ON”
IGN 2 switch “OFF”, INT switch “ON”: resume the intermittent time when turning
“ON” 1)
2)
3)
(3) Controls when the wiper motor parking is defective
Page 198 of 444

0-25
STICS
RODIUS 2007.07
8710-01
9) Battery Saver (Tail Lamp Auto Cut)
The tail lamp is turn on or off according to the operations of the multifunction tail lamp switch.
<007b008f008c0047009b0088009000930047009300880094009700470099008c0093008800a000470090009a0047009b009c00990095008c008b00470096008d008d0047004f0088009c009b00960047008a009c009b00500047009e008f008c0095004700
960097008c009500900095008e004700880095008b0047008a>losing the driver’s door
after removing the ignition key without turning off the tail lamp.
Tail lamp relay is turned on when inserting the ignition key into ignition switch again after
step 2 operation.
<007b008f008c0047009b0088009000930047009300880094009700470099008c0093008800a000470090009a0047009b009c00990095008c008b00470096008d008d0047004f0088009c009b00960047008a009c009b00500047009e008f008c0095004700
960097008c009500900095008e004700880095008b0047008a>losing the driver’s door
while the ignition key is removed and the tail lamp is turned on. 1.
2.
3.
4.
Page 200 of 444

0-27
STICS
RODIUS 2007.07
8710-01
This vehicle has the windshield heated glass and the tailgate and outside rearview mirror
heated glass. The heater relay in the ICM box controls the tailgate and outside rearview mirro
r
heated glass and its fuse (15A) is located in the engine compartment fuse box.
Defogger switch
Page 206 of 444

0-33
STICS
RODIUS 2007.07
8710-01
12) Time Lag Power Window Control
The power window is turned off when turning the ignition key to “ON” position.
The power window relay is turned “ON” for 90 seconds (T1) when turning the ignition
key to “OFF” position.
However, the power window relay stays on for 90 seconds (T2) when the ignition key is
turned to “OFF” position while the door is opened.
The power window relay is turned “ON” again for 90 seconds (T2) just for once when
opening the door during its extended operation period of 90 seconds (T1).
The power window relay is turned “OFF” when closing the door during its extended
operation period of 90 seconds (T2). 1.
2.
3.
4.
Page 211 of 444

0-38
RODIUS 2007.07
8710-01
STICS
14) Theft Deterrent
(1) Description of Burglar Alarm Function
Description of Burglar Alarm Function ▶
The “LOCK” output is “ON” when receiving the “LOCK” signal from transmitter while
the ignition key is removed and all doors are closed. The armed mode is activated when the
door lock switch is locked (theft deterrent horn output: once, hazard relay output: twice).
The theft deterrent horn and hazard relay outputs are “ON” when receiving the “LOCK”
signal from the remote control key again in armed mode (theft deterrent horn output: once,
hazard relay output: twice).
When receiving “LOCK” signal from the remote control key while any of doors is not
closed, only the “LOCK” output can be done and then activates the armed ready mode
(without theft deterrent horn and hazard warning flasher). At this moment, if the ignition key
is in the ignition switch, the door unlock switch is turned “ON” or the door lock switch
is unlocked (after 0.6 seconds), cancels the armed mode and activates the normal mode.
However, in these cases, if closing the door and locking the door lock switch, the theft
deterrent horn outputs once and the hazard warning flasher outputs twice and then activates
armed mode.
When the door is not opened or the ignition key is not inserted into ignition switch for 30
seconds after receiving “UNLOCK” signal, outputs “LOCK” and then activates armed
mode (RELOCK operation). Also, at this moment, the system outputs the theft deterrent
horn and hazard warning flasher.
The armed mode will not be activated except above conditions.
Ex) The armed mode will not be activated when the door is locked by the ignition key. 1.
2.
3.
4.
5.
Page 239 of 444

0-4
RODIUS 2007.07
8610-11
RAIN SENSOR
ICM box
The wiper related relays are installed in
ICM box.
Relay5
(Wiper INT-Low)Relay6
(Wiper High)
STICS
The rain sensing unit detects the amount of rain drops and
sends the operating signal to STICS, and STICS drives the
wiper directly.
At this moment, STICS determines the wiper operation mode
(washer, MIST, AUTO), then sends the information to the rain
sensor.