engine SSANGYONG RODIUS 2012 Service Manual

SSANGYONG RODIUS 2012 Service Manual RODIUS 2012 SSANGYONG SSANGYONG https://www.carmanualsonline.info/img/67/57525/w960_57525-0.png SSANGYONG RODIUS 2012 Service Manual

Page 352 of 715

SSANGYONG RODIUS 2012  Service Manual 15-270000-00
Load Engine speedSwirl 
valveAmount of 
swirlRemarks
Low speed,
Low loadbelow 3,000 rpm Closed HeavyIncreased EGR ratio, better air-fuel 
mixture (reduce exhaust gas))
High speed,
High lo

Page 353 of 715

SSANGYONG RODIUS 2012  Service Manual 15-28
Electric throttle 
bodyAccelerator 
pedal 
moduleD20DTR 
ECU
(9) EGR control
A. Overview
The EGR (Electric-Exhaust Gas Recirculation) valve reduces the NOx emission level by recirculating 
some

Page 355 of 715

SSANGYONG RODIUS 2012  Service Manual 15-30
D. Bypass control for EGR cooler
Cooler temperature ▶
<007e008f008c00950047009b008f008c0047008a00960096009300880095009b0047009b008c00940097008c00990088009b009c0099008c00470090009a00470089008c0

Page 356 of 715

SSANGYONG RODIUS 2012  Service Manual 15-310000-00
F. Features
As EGR ratio goes up, smoke volume will be 
higher. But, this lowers the combustion 
chamber temperature and accordingly the 
concentration of NOx is decreased. The point 
wit

Page 357 of 715

SSANGYONG RODIUS 2012  Service Manual 15-32
(10) E-VGT control
A. Overview
E-VGT (Electric-Variable Geometry Turbine) turbocharger system in D20DTF engine uses the venturi 
effect that controls the flow rate of exhaust gas by adjusting th

Page 359 of 715

SSANGYONG RODIUS 2012  Service Manual 15-34
D. E-VGT system control
Turbocharger system operates the E-VGT actuator according to the signals for engine epm, accelerator 
pedal position, atmospheric pressure, T-MAP, coolant temperature and

Page 360 of 715

SSANGYONG RODIUS 2012  Service Manual 15-350000-00
HFM (intake air 
temperature)CDPF
Electric throttle 
bodyCoolant 
temperature 
sensorOxygen sensor
Injector (C3I)
E-EGR valve
(11) Wide band oxygen sensor control
A. Overview
For diesel e

Page 363 of 715

SSANGYONG RODIUS 2012  Service Manual 15-38
Relay box
A/C 
compressorHFM (intake air 
temperature)Cooling fan 
module
MB 5 A/T (ATF 
temperature)Coolant 
temperature 
sensor
(12) Cooling fan control
A. Overview of cooling fan and A/C comp

Page 365 of 715

SSANGYONG RODIUS 2012  Service Manual 15-40
D. Cooling fan and A/C compressor control
 Conditions for cooling fan control ▶
The PWM cooling fan is set by coolant temperature and A/C refrigerant pressure. And, the setting value 
in A/T e

Page 366 of 715

SSANGYONG RODIUS 2012  Service Manual 15-410000-00
A/C compressor OFF conditions ▶
Coolant temperature: below -20℃ or over 
115℃
Engine rpm: over 4500 rpm
Engine rpm: below 600 rpm
When abrupt acceleration
Very high load during idli