tyre pressure SUZUKI GRAND VITARA 1999 2.G Service Workshop Manual
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 1999, Model line: GRAND VITARA, Model: SUZUKI GRAND VITARA 1999 2.GPages: 801, PDF Size: 12.15 MB
Page 77 of 801
YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
Page 546 of 801
YH4
GRAND
VITARA
8C-4 INSTRUMENTATION / DRIVER INFORMATION
DIAGNOSIS
NOTE:
Fuse name (ª º) in the table below is shown on the fuse box cover (Hard Top Model) or the junction box
(Canvas Top Model).
SPEEDOMETER AND VSS
TroublePossible CauseCorrection
Speedometer shows no
operationªIG / METERº fuse blown (Hard Top
Model)
ªIGº fuse blown (Canvas Top Model)
VSS faulty
Printed plate in combination meter
faulty
Speedometer faulty
Wiring or grounding faultyReplace fuse to check for short
Replace VSS
Replace printed plate
Replace speedometer
Repair
FUEL METER / FUEL GAUGE UNIT
TroublePossible CauseCorrection
Fuel meter shows no
operationªIG / METERº fuse blown (Hard Top
Model)
ªIGº fuse blown (Canvas Top Model)
Fuel gauge unit faulty
Printed plate in combination meter
faulty
Fuel meter faulty
Wiring or grounding faultyReplace fuse to check for short
Replace fuel gauge unit
Replace printed plate
Replace fuel meter
Repair
ENGINE COOLANT TEMP. (ECT) METER AND SENSOR
TroublePossible CauseCorrection
Engine coolant temp.
meter shows no operationªIG / METERº fuse blown (Hard Top
Model)
ªIGº fuse blown (Canvas Top Model)
ECT meter faulty
Printed plate in combination meter
faulty
ECT sensor faulty
Wiring or grounding faultyReplace fuse to check for short
Replace ECT meter
Replace printed plate
Replace ECT sensor
Repair
OIL PRESSURE LIGHT
TroublePossible CauseCorrection
Oil pressure warning light
does not light upBulb in combination meter blown
ªIG / METERº fuse blown (Hard Top
Model)
ªIGº fuse blown (Canvas Top Model)
Printed plate in combination meter
faulty
Oil pressure switch faulty
Wiring or grounding faultyReplace bulb
Replace fuse to check for short
Replace printed plate
Replace oil pressure switch
Repair