Evap SUZUKI GRAND VITARA 2000 2.G Service Workshop Manual
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 2000, Model line: GRAND VITARA, Model: SUZUKI GRAND VITARA 2000 2.GPages: 801, PDF Size: 12.15 MB
Page 24 of 801
YH4
GRAND
VITARA
GENERAL INFORMATION 0A-21
A
ABS : Anti-lock Brake System
ATDC : After Top Dead Center
API : American Petroleum Institute
ATF : Automatic Transmission Fluid
ALR : Automatic Locking Retractor
AC : Alternating Current
A / T : Automatic Transmission
A / C : Air Conditioning
ABDC : After Bottom Dead Center
A / F : Air Fuel Mixture Ratio
A-ELR : Automatic-Emergency
Locking Retractor
B
B+ : Battery Positive Voltage
BTDC : Before Top Dead Center
BBDC : Before Bottom Dead Center
C
CKT : Circuit
CMP Sensor : Camshaft Position Sensor
(Crank Angle Sensor, CAS)
CO : Carbon Monoxide
CPP Switch : Clutch Pedal Position Switch
(Clutch Switch, Clutch Start
Switch)
CPU : Central Processing Unit
CRS : Child Restraint System
D
DC : Direct Current
DLC : Data Link Connector
(Assembly Line Diag. Link,
ALDL, Serial Data Link, SDL)
DOHC : Double Over Head Camshaft
DOJ : Double Offset Joint
DRL : Daytime Running Light
DTC : Diagnostic Trouble Code
(Diagnostic Code)
E
EBCM : Electronic Brake Control
Module, ABS Control
Module
EBD : Electric Brake force Distribution
ECM : Engine Control Module
ECT Sensor : Engine Coolant Temperature
Sensor (Water Temp.
Sensor, WTS)
EGR : Exhaust Gas Recirculation
EGRT Sensor : EGR Temperature Sensor
(Recirculated Exhaust Gas
Temp. Sensor, REGTS)
EFE Heater : Early Fuel Evaporation
Heater (Positive Temperature
Coefficient, PTC Heater)
ELR : Emergency Locking Retractor
EPS : Electronic Power Steering
EVAP : Evaporative Emission
EVAP Canister : Evaporative Emission
Canister (Charcoal Canister)
F
4WD : 4 Wheel Drive
G
GEN : Generator
GND : Ground
H
HC : Hydrocarbons
HO2S : Heated Oxygen Sensor
I
IAC Valve : Idle Air Control Valve (Idle
Speed Control Solenoid
Valve, ISC Solenoid Valve)
IAT Sensor : Intake Air Temperature
Sensor (Air temperature
Sensor, ATS)
ICM : Immobilizer Control Module
IG : Ignition
ISC Actuator : Idle Speed Control Actuator
(Motor)
ABBREVIATIONS MAY BE USED IN THIS MANUAL
Page 29 of 801
YH4
GRAND
VITARA
0B-2 MAINTENANCE AND LUBRICATION
MAINTENANCE SCHEDULE
MAINTENANCE SCHEDULE UNDER NORMAL DRIVING CONDITIONS
Interval:
This interval should be judged by
This table includes services as scheduled up to 90,000 km
(54,000 miles) mileage. Beyond 90,000 km (54,000 miles), carry
out the same services at the same intervals respectively.
This interval should be judged by
odometer reading or months,Km (x 1,000)153045607590g
whichever comes first.Miles (x 1,000)91827364554
Months122436486072
ENGINE
1-1. Drive beltV-beltIRIRIR
V-rib belt (Flat type)±±I±±R
1-2. Camshaft timing belt (G16 engine only)Replace every 100,000 km or
60,000 miles
1-3. Valve lash (clearance)G16 engine only±I±I±I
1-4. Engine oil and
oil filterJ20 / H25 engines
G16 engine with HO2S (SG, SH, SJ)RRRRRR
G16 engine with HO2S (SE, SF),
G16 engine without HO2SReplace every 10,000 km (6,000 miles)
or 8 months
1-5. Engine coolant±±R±±R
1-6. Exhaust system±I±I±I
IGNITION SYSTEM
2-1. Spark plugs
Wh
Vehicle without
HO2S
Nickel plug±R±R±R
When
unleaded
HO2SIridium plug±±±R±±unleaded
fuel isVehicle with
HO2S
Nickel plug±±R±±Rfuel is
usedHO2SIridium plugReplace every 105,000 km or 63,000
miles
When leaded fuel is used, refer to ªSevere Driving Conditionº schedule
FUEL SYSTEM
3-1. Air cleaner filterIIRIIR
3-2. Fuel lines and connections±I±I±I
3-3. Fuel filterReplace every 105,000 km or 63,000
miles
3-4. Fuel tank±±I±±I
EMISSION CONTROL SYSTEM
4-1. Crankcase ventilation hoses and connections
(Vehicle without HO2S)±±I±±I
4-2. PCV valveVehicle without HO2S±±I±±I
Vehicle with HO2S±±±±±I
4-3. Fuel evaporative emission
tl t
Vehicle without HO2S±I±I±I
control systemVehicle with HO2S±±±±±I
NOTES:
ªRº : Replace or change
ªIº : Inspect and correct, replace or lubricate if necessary
For Item 1-2. Camshaft timing belt: This belt may be replaced every 90,000 km (54,000 miles) according
to customer's maintenance convenience.
For Sweden, item 2-1, 4-2 and 4-3 should be performed by odometer reading only.
For Item 2-1. Spark plugs, replace every 50,000 km if the local law requires.
Nickel spark plug: BKR6E-11 or K20PR-U11
Iridium spark plug: IFR6E11 or SK20PR-A11 for G16 engine, IFR5J11 or SK16PR11 for J20 / H25 engines
Page 41 of 801
YH4
GRAND
VITARA
[A]
[B]
[A]: Type 1
[B]: Type 2
0B-14 MAINTENANCE AND LUBRICATION
EMISSION CONTROL SYSTEM
ITEM 4-1
Crankcase Ventilation Hoses and Connections Inspection
(Vehicle not equipped with oxygen sensor)
Refer to the following item 4-2, PCV valve inspection.
ITEM 4-2
PCV (Positive Crankcase Ventilation) Valve Inspection
Check crankcase ventilation hose and PCV hose for leaks, cracks
or clog, and PCV valve for stick or clog. Refer to On-vehicle service
of Section 6E1 / 6E2 for PCV valve checking procedure.
ITEM 4-3
Evaporative Emission Control System Inspection
1) Visually inspect hoses for cracks, damage, or excessive bends.
Inspect all clamps for damage and proper position.
2) Check EVAP canister for operation and clog, referring to Section
6E1 / 6E2.
If a malfunction is found, repair or replace.
Page 58 of 801
YH4
GRAND
VITARA
1A-6 HEATER AND VENTILATION
6) Remove cooling unit (If equipped).
Refer to item COOLING UNIT (EVAPORATOR) REMOVAL in
Section 1B.
7) Disconnect fresh air control cable from blower motor case.
8) Remove blower motor unit (1) by removing its fastening nuts
(2).
9) Disconnect blower motor lead wire (2) at coupler from blower
unit (1).
10) Remove blower motor (3) by removing its mounting screws (4).
INSTALLATION
1) Reverse removal procedure for installation.
2) Connect fresh air control cable, refer to HEATER CONTROL
CABLES INSTALLATION.
3) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
Page 69 of 801
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-17
1. Dash panel (engine room) 2. Nuts
REMOVAL
WARNING:
Failure to follow the following procedure and WARNING
may cause air bag deployment, personal injury, damage to
parts, or air bag being unable to deploy.
Never rest a steering column assembly on steering wheel
with air bag (inflator) module face down and column verti-
cal.
When handling the air bag (inflator) modules (driver and
passenger), be careful not to drop it or apply an impact to
it. If an excessive impact was applied (e.g., dropped from
a height of 91.4 cm (3 feet) or more, never attempt disas-
sembly or repair but replace it with a new one.
When grease, cleaning agent. Oil, water, etc. has got onto
air bag (inflator) modules (driver and passenger), wipe off
immediately with a dry cloth.
1) Disconnect negative (±) cable at battery.
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Drain engine coolant and disconnect heater hose (1) from
heater unit.
4) Remove instrument panel, refer to item INSTRUMENT PANEL
REMOVAL in Section 9.
5) Remove cooling unit (If equipped).
Refer to item EVAPORATOR (COOLING UNIT) REMOVAL in
Section 1B.
6) Disconnect rear duct (4) from heater unit.
7) Disconnect heater mode control actuator lead wire (1) at cou-
plers.
8) Remove A / C controller (2) (If equipped).
9) Remove SDM (3) (If equipped).
10) Remove heater unit.
Page 73 of 801
YH4
GRAND
VITARA
1B-2 AIR CONDITIONING (OPTIONAL)
Condenser Dryer (Receiver / Dryer) 1B-36. . . . . .
Air Filter Element 1B-37. . . . . . . . . . . . . . . . . . . . .
Cooling Unit (Evaporator) 1B-39. . . . . . . . . . . . . .
Expansion Valve 1B-42. . . . . . . . . . . . . . . . . . . . .
A / C Evaporator Thermistor (Evaporator
Temperature Sensor) 1B-43. . . . . . . . . . . . . . . .
Refrigerant Pipes and Hoses 1B-44. . . . . . . . . . .
A / C Switch 1B-45. . . . . . . . . . . . . . . . . . . . . . . . . .
A / C Controller 1B-46. . . . . . . . . . . . . . . . . . . . . . . .
Dual Pressure Switch 1B-47. . . . . . . . . . . . . . . . . A / C Compressor Relay and A / C
Condenser Cooling Fan Relay 1B-48. . . . . . . .
Compressor Assembly 1B-49. . . . . . . . . . . . . . . .
Magnet Clutch Assembly
(For Denso Compressor) 1B-53. . . . . . . . . . .
Magnet Clutch Assembly
(For Seiko Seiki Compressor) 1B-56. . . . . . .
Lip Type Seal (For Seiko Seiki) 1B-59. . . . . . .
REQUIRED SERVICE MATERIAL1B-61 . . . . . . . .
SPECIAL TOOLS1B-61 . . . . . . . . . . . . . . . . . . . . . .
Page 75 of 801
YH4
GRAND
VITARA
1. Compressor
2. Magnet clutch
3. Condenser assembly
4. Receiver / dryer
5. Dual pressure switch
6. Expansion valve
7. Evaporator: Liquid
: Vapor
: Superheated vapor
1B-4 AIR CONDITIONING (OPTIONAL)
REFRIGERANT FLOW OF AIR CONDITIONING SYSTEM
Page 77 of 801
YH4
GRAND
VITARA
1B-6 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS
GENERAL
ConditionPossible CauseCorrection
Cool air won't come out
(A / C system won't
operative)No refrigerant
Fuse blown
A / C switch faulty
Blower motor switch faulty
A / C thermistor faulty
Dual pressure switch faulty
Wiring or grounding faulty
A / C ON permission signal in ECM
faulty
A / C controller and its circuit faultyRecover, evacuation and charging.
Check ªIG METERº fuse, ªREAR DEFGº
fuse, and ªA / C FUSEº and check for
short circuit to ground.
Check A / C switch.
Check blower motor switch.
Check A / C evaporator thermistor.
Check dual pressure switch.
Repair as necessary.
Check ON permission signal.
Check A / C controller and its circuit.
Cool air won't come out
(A / C compressor won't
operative)Magnet clutch faulty
Compressor relay faulty
Compressor thermal switch faulty
(if equipped)
Drive belt loose or broken
Compressor faulty
A / C ON permission signal in ECM
faulty
A / C controller faultyCheck magnet clutch.
Check compressor thermal switch.
Check compressor relay.
Adjust or replace drive belt.
Check compressor.
Check ON permission signal.
Check A / C controller.
Cool air won't come out
(A / C condenser cooling
fan motor won't
operative)Condenser cooling fan relay faulty
Wiring or grounding faulty
ªA / C condenser cooling fan relayº
signal in ECM faulty
Condenser cooling fan motor faultyCheck condenser cooling fan relay.
Repair as necessary.
Check A / C condenser cooling fan relay
signal.
Check condenser cooling fan motor.
Cool air won't come out
(Blower motor won't
operative)Fuse blown
Blower motor relay faulty
Blower motor resistor faulty
Blower motor switch faulty
Wiring or grounding faulty
Blower motor faultyCheck ªHEATER FUSEº, ªREAR DEFGº
fuse and check for short circuit to
ground.
Check blower motor relay.
Check blower motor resistor.
Check blower motor switch.
Repair as necessary.
Check blower motor.
Cool air won't come out
or insufficient cooling
(A / C system normal
operative)Insufficient or excessive charge of
refrigerant
Refrigerant leak in system
Condenser clogged
A / C evaporator clogged or frosted
A / C thermistor faulty
A / C controller faulty
Expansion valve faulty
Drive belt slipping
Magnetic clutch faultyCheck charge of refrigerant.
Check system for leaks.
Check condenser.
Check A / C evaporator.
Check A / C thermistor.
Check A / C controller.
Check expansion valve.
Check or replace drive belt.
Check magnetic clutch.
Page 78 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-7
ConditionPossible CauseCorrection
Cool air does not come
out or insufficient
cooling (A / C system
normal operative)Compressor faulty
Air in A / C system
Air leaking from cooling unit or air
duct
Heater and ventilation system faulty
Blower motor faulty
Excessive compressor oil existing in
A / C systemCheck compressor.
Replace condenser dryer, and
evacuation and charging.
Repair as necessary.
Check blower unit.
Check heater control lever assembly.
Check heater assembly.
Check blower motor.
Pull out compressor oil in A / C system
circuit, and replace compressor.
Cool air does not comes
out only intermittentlyWiring connection faulty
Expansion valve faulty
Excessive moisture in A / C system
A / C controller faulty
Magnetic clutch faulty
Excessive charge of refrigerantRepair as necessary.
Check expansion valve.
Replace condenser dryer, and
evacuation and charging.
Check A / C controller.
Check magnetic clutch.
Check charge of refrigerant.
Cool air comes out only
at high speedsCondenser clogged
Insufficient charge of refrigerant
Air in A / C system
Drive belt slipping
Compressor faultyCheck condenser.
Check charge of refrigerant.
Replace condenser dryer, and
evacuation and charging.
Adjust or replace drive belt.
Check compressor.
Cool air does not comes
out only at high speedsExcessive charge of refrigerant
A / C evaporator frostedCheck charge refrigerant.
Check A / C evaporator.
Check A / C thermistor.
Insufficient velocity of
cooled airA / C evaporator clogged or frosted
Air leaking from cooling unit or air
duct
Blower motor faulty
Wiring or grounding faultyCheck A / C evaporator.
Repair as necessary.
Check blower motor.
Repair as necessary.
Page 80 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-9
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
ConditionPossible CauseCorrection
A large rattling noise is heard at
idle or sudden acceleration.Loosen pulley mounting bolt.
Worn or broken bearings.Retighten bolt.
Replace bearings.
ABNORMAL NOISE FROM TENSION PULLEY
ConditionPossible CauseCorrection
Clattering noise is heard from
pulley.
Pulley cranks upon contact.Worn or damaged bearings.
Cracked or loose bracket.Replace bearings.
Replace or retighten bracket.
ABNORMAL NOISE FROM EVAPORATOR
ConditionPossible CauseCorrection
Whistling sound is heard from
evaporator.Depending on the combination of
the interior / exterior
temperatures, engine rpm and
refrigerant pressure, the
refrigerant flowing out of the
expansion valve may, under
certain conditions, make a
whistling sound.At times, slightly decreasing
refrigerant volume may stop this
noise.
Inspect expansion valve and
replace if faulty.
ABNORMAL NOISE FROM BLOWER MOTOR
ConditionPossible CauseCorrection
Blower motor emits a chirping
sound in proportion to its speed of
rotation.
Fluttering noise or large droning
noise is heard from blower motor.Worn or damaged motor brushes
or commutator.
Leaves or other debris
introduced from fresh air inlet to
blower motor.Repair or replace blower motor.
Remove debris and make sure
that the screen at fresh air inlet is
intact.