0B-24 MAINTENANCE AND LUBRICATION
FINAL INSPECTION
Seats
Check that seat slides smoothly and locks securely at
any position. Also check that reclining mechanism of
front seat back allows it to be locked at any angle.
Seat Belt
Inspect belt system including webbing, buckles, latch
plates, retractors and anchors for damage or wear.
If ªREPLACE BELTº label on front seat belt is visible,
replace belt.
Check that seat belt is securely locked.
Battery Electrolyte Level Check
Check that the electrolyte level of all battery cells is
between the upper and lower level lines on the case.
If battery is equipped with built-in indicator, check bat-
tery condition by the indicator.
Accelerator Pedal Operation
Check that pedal operates smoothly without getting
caught or interfered by and other part.
Engine Start
Check engine start for readiness.
On automatic transmission vehicles, try to start the
engine in each select lever position. The starting mo-
tor should crank only in ªPº (Park) or ªNº (Neutral).
On manual transmission vehicles, place the shift le-
ver in ªNeutral,º depress clutch pedal fully and try to
start.
Exhaust System Check
Check for leakage, cracks or loose supports.
Clutch (For Manual transmission)
Check for the following:
Clutch is completely released when depressing
clutch pedal.
No slipping clutch occurs when releasing pedal and
accelerating.
Clutch itself is free from any abnormal condition.
Gearshift or Select Lever (Transmission)
Check gear shift or select lever for smooth shifting to
all positions and for good performance of transmis-
sion in any position.
With automatic transmission equipped vehicle, also
check that shift indicator indicates properly according
to which position select lever is shifted to.
With automatic transmission equipped vehicle, make
sure that vehicle is at complete stop when shifting se-
lect lever to ªPº range position and release all brakes.
Brake
[Foot brake]
Check the following:
that brake pedal has proper travel,
that brake works properly,
that it is free from noise,
that braking force is applied equally on all wheels,
and that brake do not drag.
[Parking brake]
Check that lever has proper travel.
WARNING:
With vehicle parked on a fairly steep slope,
make sure nothing is in the way downhill to
avoid any personal injury or property damage.
Be prepared to apply regular brake quickly
even if vehicle should start to move.
Check to ensure that parking brake is fully effective
when the vehicle is stopped on the safe slope and
brake lever is pulled all the way.
WARNING:
When carrying out road tests, select a safe
place where no man or no running vehicle is
seen so as to prevent any accident.
WARNING:
Before performing the following check, be
sure to have enough room around the vehicle.
Then, firmly apply both the parking brake and
the regular brakes. Do not use the accelerator
pedal. If the engine starts, be ready to turn off
the ignition promptly. Take these precautions
because the vehicle could move without warn-
ing and possibly cause personal injury or
property damage.
Page 52 of 801
YH4
GRAND
VITARA
MAINTENANCE AND LUBRICATION 0B-25
Steering
Check to ensure that steering wheel is free from in-
stability, or abnormally heavy feeling.
Check that the vehicle does not wander or pull to
one side.
Engine
Check that engine responds readily at all speeds.
Check that engine is free from abnormal noise and
abnormal vibration.
Body, Wheels and Power Transmitting System
Check that body, wheels and power transmitting sys-
tem are free from abnormal noise and abnormal
vibration or any other abnormal condition.
Meters and Gauge
Check that speedometer, odometer, fuel meter, tem-
perature gauge, etc. are operating accurately.
Lights
Check that all lights operate properly.
Windshield Defroster
Periodically check that air comes out from defroster
outlet when operating heater or air conditioning.
Set fan switch lever to ªHIº position for this check.
RECOMMENDED FLUIDS AND LUBRICANTS
Engine oilSG, SH or SJ (Refer to engine oil viscosity chart in item 1-4)
Engine coolant (Ethylene glycol
base coolant)ªAntifreeze / Anticorrosion coolantº
Brake fluidDOT 3
Manual transmission oilRefer to Section 7A or 7A1Transfer oilRefer to Section 7A or 7A1.
Differential oil (front & rear)Refer to Section 7E or 7F.
Automatic transmission fluid and
Power steering fluidRefer to Section 3B1 or 7B1.
Door hingesEngine oil or water resistance chassis greaseHood latch assemblyEngine oil or water resistance chassis grease
Key lock cylinderSpray lubricant
Page 69 of 801
YH4
GRAND
VITARA
HEATER AND VENTILATION 1A-17
1. Dash panel (engine room) 2. Nuts
REMOVAL
WARNING:
Failure to follow the following procedure and WARNING
may cause air bag deployment, personal injury, damage to
parts, or air bag being unable to deploy.
Never rest a steering column assembly on steering wheel
with air bag (inflator) module face down and column verti-
cal.
When handling the air bag (inflator) modules (driver and
passenger), be careful not to drop it or apply an impact to
it. If an excessive impact was applied (e.g., dropped from
a height of 91.4 cm (3 feet) or more, never attempt disas-
sembly or repair but replace it with a new one.
When grease, cleaning agent. Oil, water, etc. has got onto
air bag (inflator) modules (driver and passenger), wipe off
immediately with a dry cloth.
1) Disconnect negative (±) cable at battery.
2) Disable air bag system, if equipped. Refer to DISABLING AIR
BAG SYSTEM in Section 10B.
3) Drain engine coolant and disconnect heater hose (1) from
heater unit.
4) Remove instrument panel, refer to item INSTRUMENT PANEL
REMOVAL in Section 9.
5) Remove cooling unit (If equipped).
Refer to item EVAPORATOR (COOLING UNIT) REMOVAL in
Section 1B.
6) Disconnect rear duct (4) from heater unit.
7) Disconnect heater mode control actuator lead wire (1) at cou-
plers.
8) Remove A / C controller (2) (If equipped).
9) Remove SDM (3) (If equipped).
10) Remove heater unit.
Page 70 of 801
YH4
GRAND
VITARA
1A-18 HEATER AND VENTILATION
11) Remove heater core pipe clamps (1) and grommet (2).
12) Pull out heater core (1) from unit (2).
INSTALLATION
1) Install heater unit by reversing removal procedure, noting the
following items.
When installing each part, be careful not to catch any cable or
wiring harness.
When installing steering column assembly, refer to STEER-
ING COLUMN INSTALLATION in Section 3C or 3C1.
2) Install control cables. (Refer to HEATER CONTROL CABLES in
this section.)
3) Fill engine coolant to radiator.
4) Enable air bag system, if equipped. Refer to ENABLING AIR
BAG SYSTEM in Section 10B.
5) Evacuate and charge system. Refer to items EVACUATING
SYSTEM and PROCEDURE OF CHARGING in Section 1B.
Page 79 of 801
YH4
GRAND
VITARA
1B-8 AIR CONDITIONING (OPTIONAL)
DIAGNOSIS OF ABNORMAL NOISE
There are various types of noise, ranging from those produced in the engine compartment to those from the pas-
senger compartment, also from rumbling noises to whistling noises.
ABNORMAL NOISE FROM COMPRESSOR
ConditionPossible CauseCorrection
During compressor operation, a
rumbling noise is heard
proportional to engine
revolutions.Inadequate clearance in piston
area (piston or swash-plate).Repair or replace compressor as
necessary.
A loud noise is heard at a certain
rpm, disproportionately to engine
revolution.Loose or faulty V-belt.
Loose mounting bolts.Adjust V-belt tension, or
replace belt.
Retighten mounting bolts.
A loud rattle is heard at low
engine rpm.Loose compressor center bolt.Retighten center bolt.
Replace compressor if it was
operated in this condition for a
long time.
ABNORMAL NOISE FROM MAGNETIC CLUTCH
ConditionPossible CauseCorrection
A rumbling noise is heard when
compressor is not operating.Worn or damaged bearings.Replace bearings.
A chattering noise is heard when
compressor is engaged.Faulty clutch gap (excessive).
Worn clutch friction surface.
Compressor oil leaked from shaft
seal, contaminating the friction
surface.Adjust clutch gap.
Replace clutch.
Replace compressor shaft oil
seal.
ABNORMAL NOISE FROM TUBING
ConditionPossible CauseCorrection
A droning noise is heard inside
vehicle, but not particularly
noticeable in engine
compartment.Faulty tubing clamps.
Resonance caused by pulsation
from variations in refrigerant
pressure.Reposition clamps or increase
the number of clamps.
Attach a silencer to tubing, or
modify its position and length.
ABNORMAL NOISE FROM CONDENSER
ConditionPossible CauseCorrection
Considerable vibration in
condenser.Resonance from condenser
mounting stay and body.Firmly insert a silencer between
condenser mounting stay and
body.
Page 80 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-9
ABNORMAL NOISE FROM CRANKSHAFT PULLEY
ConditionPossible CauseCorrection
A large rattling noise is heard at
idle or sudden acceleration.Loosen pulley mounting bolt.
Worn or broken bearings.Retighten bolt.
Replace bearings.
ABNORMAL NOISE FROM TENSION PULLEY
ConditionPossible CauseCorrection
Clattering noise is heard from
pulley.
Pulley cranks upon contact.Worn or damaged bearings.
Cracked or loose bracket.Replace bearings.
Replace or retighten bracket.
ABNORMAL NOISE FROM EVAPORATOR
ConditionPossible CauseCorrection
Whistling sound is heard from
evaporator.Depending on the combination of
the interior / exterior
temperatures, engine rpm and
refrigerant pressure, the
refrigerant flowing out of the
expansion valve may, under
certain conditions, make a
whistling sound.At times, slightly decreasing
refrigerant volume may stop this
noise.
Inspect expansion valve and
replace if faulty.
ABNORMAL NOISE FROM BLOWER MOTOR
ConditionPossible CauseCorrection
Blower motor emits a chirping
sound in proportion to its speed of
rotation.
Fluttering noise or large droning
noise is heard from blower motor.Worn or damaged motor brushes
or commutator.
Leaves or other debris
introduced from fresh air inlet to
blower motor.Repair or replace blower motor.
Remove debris and make sure
that the screen at fresh air inlet is
intact.
Page 81 of 801
YH4
GRAND
VITARA
3. Bubbles
1B-10 AIR CONDITIONING (OPTIONAL)
QUICKLY CHECKING OF REFRIGERANT
CHARGE (IF EQUIPPED WITH SIGHT GLASS)
CHARGE OF REFRIGERANT
The following procedure can be used for quickly checking whether
the A / C system has a proper charge of refrigerant or not.
Run engine at fast idle, and operate A / C at its max. cooling capacity
for a few minutes. Then, look at the sight glass (1) on receiver / dryer
(2) and compare what is observed with the symptoms listed in
ªCHECKING REFRIGERANT CHARGEº table given below.
CHECKING REFRIGERANT CHARGE
CONDITIONPOSSIBLE CAUSESCORRECTION
Bubbles observed in sight glassInsufficient charge of refrigerant in
systemCheck system for leaks with a leak
tester.
No bubbles observed in sight glassNo charge or proper or too much
charge of refrigerant in systemRefer to the following item.
No temperature difference
between compressor inlet and
outletEmpty or nearly empty systemRecovery, evacuate and charge
system and then check it for leaks
with a leak tester.
Noticeable temperature difference
between compressor inlet and
outletProper or too much charge of
refrigerant in systemRefer to the following item.
When A / C is turned OFF,
refrigerant in sight glass clears
immediately and remains clearToo much charge of refrigerant in
systemDischarge excess charge of
refrigerant to adjust it to a specified
charge.
When A / C is turned OFF,
refrigerant in sight glass once
produces bubbles and then clearsProper charge of refrigerant in
systemNo correction needed because
charge of refrigerant is normal.
Page 83 of 801
YH4
GRAND
VITARA
For CAMI production vehicle
For IWATA production vehicle
1B-12 AIR CONDITIONING (OPTIONAL)
PERFORMANCE DIAGNOSIS
1) Confirm that vehicle and environmental conditions are as fol-
lows.
Vehicle is not exposed to direct sun.
Ambient temperature is within 15C ± 35C (59F ± 95F).
2) Make sure that high pressure valve (1) and low pressure valve
(2) of manifold gauge are firmly closed.
3) Connect high pressure charging hose (3) to high pressure ser-
vice valve (5) on vehicle, and connect low pressure charging
hose (4) to low pressure service valve (6) on vehicle.
4) Bleed the air in charging hoses (3), (4) by loosening their respec-
tive nuts on manifold gauge, utilizing the refrigerant pressure.
When a hiss is heard, immediately tighten nut.
CAUTION:
Do not interchange high and low pressure charging
hoses by mistake.
5) Warm up engine to normal operating temperature (engine cool-
ant temperature at 80 ± 90C (176 ± 194F)) and keep it at spe-
cified idle speed. (Radiator cooling fan should not be working
when checking pressure and temperature.)
6) Turn A / C switch ON, and set blower switch at ªHIº (4th position),
temperature control knob at ªCOOLº, air outlet control knob at
ªFACEº, fresh / circulation control knob at ªCIRCULATIONº.
(Confirm that A / C compressor and condenser fan are working.)
7) Keep all windows, doors and engine food open.
Ambient temperature
15 ± 35C (59F ± 95F)
Engine rpmKeep to 1,500 rpm.
Blower motor switchMax. (4th position)
Temperature controlMax. cool
Air outlet controlFace
Vehicle doorsAll open
Air inlet door positionRecirculation
8) With about 20 mm (0.8 in.) of dry bulb thermometer (1) inserted
into center duct air outlet and another one set near evaporator
air inlet, read temperature indicated on each thermometer.
Page 85 of 801
YH4
GRAND
VITARA
1B-14 AIR CONDITIONING (OPTIONAL)
HIGH PRESSURE CAUGE LOW PRESSURE GAUGE THERMOMETER AT
CENTER DUCT
Insufficient
cooling of
condenser
PERFORMANCE DIAGNOSIS TABLE
TESTING RESULTSPOSSIBLE CAUSEREMEDY
Pressure high
(ªAº area of high side
graph)Refrigerant overcharged
Expansion valve frozen or clogged
Clogged refrigerant passage of high side
Condenser fan malfunction
Dirty or bent condenser fins
Compressor malfunction (Insufficient oil etc.)
Engine overheatRecharge
Check expansion valve
Clean or replace
Check condenser fan
Clean or repair
Check compressor
Check engine cooling
system
Pressure low
(ªBº area of high side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check for leakage, repair if
necessary and recharge
Check expansion valve
Check compressor
Pressure high
(ªAº area of low side
graph)Expansion valve malfunction (Valve opens too
wide)
Compressor malfunction (Insufficient
compression)Check expansion valve
Check compressor
Pressure low
(ªBº area of low side
graph)Insufficient refrigerant (Insufficient charge or
leakage)
Expansion valve malfunction (Valve opens too
narrow)
Clogged refrigerant passage (Crashed pipe)Check for leakage, repair if
necessary and recharge
Check expansion valve
Repair or replace
Outlet air temperature
at center duct is high
(Crossing point is in
area ªAº)Insufficient or excessive charge of refrigerant
Dirty or bent evaporator fins
Air leakage from cooling (heater) unit or air
duct
Malfunctioning, switchover function of damper
in cooling (heater) unit
Compressor malfunctionCheck refrigerant
pressure
Clean or repair
Repair or replace
Repair or replace
Check compressor
Outlet air temperature
at center duct is low
(Crossing point is in
area ªBº)Insufficient air volume from center duct
(Heater blower malfunction)
Compressor malfunctionCheck blower motor and
fan
Check compressor
NOTE:
If ambient temperature is within 30 ± 35C (85 ± 95F), it is possible to do using next page table for more
detail diagnosis.
Page 86 of 801
YH4
GRAND
VITARA
AIR CONDITIONING (OPTIONAL) 1B-15
AMBIENT TEMPERATURE WITHIN 30 ± 35C (85 ± 95F)
CONDITION
MANIFOLD
GAUGEMPa
(kg/cm2)
(psi)DETAILCAUSECORRECTION
LoHi
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Normal condition.ÐÐÐÐ
Negative
pressure0.5 ± 0.6
(5 ± 6)
(71.2 ± 85.3)
The low pressure side
reads a negative pressure,
and the high pressure side
reads an extremely low
pressure.
Presence of frost around
tubing to and from receiver /
dryer and expansion valve. Dust particles or water
droplets are either stuck or
frozen inside expansion
valve, preventing the
refrigerant from flowing.Clean expansion valve.
Replace it if it cannot be
cleaned.
Replace receiver / dryer.
Evacuate the A / C
system and recharge
with fresh refrigerant.
Normal:
0.23 ± 0.35
(2.3 ± 3.5)
(33 ± 50)
Abnormal:
Negative
pressureNormal:
1.4 ± 1.75
(14 ± 17.5)
(200 ± 249)
Abnormal:
0.69 ± 0.98
(7 ± 10)
(100 ± 142) During A / C operation, the
low pressure side
sometimes indicates
negative pressure, and
sometimes normal
pressure. Also high
pressure side reading
fluctuates between the
abnormal and normal
pressure.Expansion valve is frozen
due to moisture in the
system, and temporarily
shuts off the refrigeration
cycle.Replace expansion
valve.
Replace receiver / dryer.
Evacuate A / C system
and recharge with fresh
refrigerant.
0.05 ± 0.15
(0.5 ± 1.5)
(4.2 ± 21.3)
0.69 ± 0.98
(7 ± 10)
(100 ± 142)
Both low and high pressure
sides indicate low readings.
Continuous air bubbles are
visible through sight glass.
Output air is slightly cold.Insufficient refrigerant in
system. (Refrigerant
leaking)Using a gas leak
detector, check for leaks
and repair as necessary.
Recharge refrigerant to a
specified amount.
If the pressure reading is
almost 0 when the
manifold gauges are
attached, check for any
leaks, repair them, and
evacuate the system.
0.4 ± 0.6
(4 ± 6)
(56.9 ± 85.3)
Pressure on low pressure
side is high.
Pressure on high pressure
side is low.
Both pressure becoming
equal right after A / C is
turned OFF.Internal leak in compressor.Inspect compressor and
repair or replace as
necessary.
035 045
High pressure reading on
both low and high pressure
sides.
Air bubbles are not visible
even when engine rpm is
lowered.Overcharged A / C system.
Faulty condenser cooling
operation.
Faulty condenser fan
operation.Adjust refrigerant to
specified amount.
Clean condenser.
Inspect and repair
condenser fan.
0.35 ± 0.45(3.5 ± 4.5)
(50 ± 64)
1.96 ± 2.45
(20 ± 25)
(285 ± 355)
High pressure reading on
both low and high pressure
sides.
Low pressure side tubing is
not cold when touched.
Air bubbles are visible
through sight glass.Presence of air in A / C
system. (Improperly
evacuated)Replace receiver / dryer.
Inspect quantity of
compressor oil and
presence of
contaminants in oil.
Evacuate system and
recharge with fresh
refrigerant.
0.45 ± 0.55
(4.5 ± 5.5)
(64 ± 78)
High pressure reading on
both low and high pressure
sides.
Large amount of frost or
dew on the low pressure
side tubing.Faulty expansion valve.
Refrigerant flow is not
regulated properly.Replace expansion
valve.