lights SUZUKI GRAND VITARA 2003 2.G Service Owner's Manual
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 2003, Model line: GRAND VITARA, Model: SUZUKI GRAND VITARA 2003 2.GPages: 801, PDF Size: 12.15 MB
Page 578 of 801

YH4
GRAND
VITARA
WINDOWS, MIRRORS, SECURITY AND LOCKS 8D-23
POWER DOOR LOCK AND KEYLESS ENTRY SYSTEM (IF KEYLESS ENTRY IS
EQUIPPED)
SYSTEM INSPECTION
STEPACTIONYESNO
1Check power door lock operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 2.Go to Step 3.
2Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 4.Go to Step 6.
3Check keyless entry operation referring to its
INSPECTION in this section.
Is this operation OK?Go to Step 5.Go to Step 7.
4Check hazard warning lights operation referring to
its INSPECTION in this section.
Is this operation OK?This system is OK.Go to Step 10.
5Check door lock key and power door lock switch
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
6Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
7Check power door lock actuator circuit referring to
its INSPECTION in this section.
Is this circuit OK?Go to Step 8.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 8.
8Check power supply and grounding circuit
referring to its INSPECTION in this section.
Is this circuit OK?Go to Step 9.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
If OK, go to Step 4.
If not OK, go to next
Step 9.
91) Check door lock key and power door lock
switch circuit referring to its INSPECTION in
this section.
2) Check ignition switch and door switch circuit
referring to its INSPECTION in this section.
Are these circuits OK?Replace controller and
recheck.
And go to Step 4.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
And go to Step 4.
Page 579 of 801

YH4
GRAND
VITARA
8D-24 WINDOWS, MIRRORS, SECURITY AND LOCKS
STEPACTIONYESNO
10Check that hazard warning lights flash with hazard
switch ON.
Is check result OK?Go to Step 11.Refer to ªTurn Signal
and Hazard Warning
Lightsº in DIAGNOSIS
and repair.
And go to Step 4.
11Check door knob switch and turn signal relay
circuit referring to its INSPECTION in this section.
Is this circuit OK?Replace controller and
recheck.Repair circuit referring
to WIRING DIAGRAM
MANUAL and recheck.
POWER DOOR LOCK OPERATION
INSPECTION
1) With the driver side door key turned LOCK, check all power
doors are locked.
2) With the driver side door key turned UNLOCK, check only the
driver side power door is unlocked.
Turn the driver side door key to UNLOCK again within 5 se-
conds, check all power doors are unlocked.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
KEYLESS ENTRY OPERATION
INSPECTION
1) With the IG switch OFF and all doors closed, push LOCK button
on transmitter. Check all power doors are locked.
2) Push UNLOCK button on transmitter. Check only driver side
power door is unlocked.
3) Push UNLOCK button on transmitter again within 5 seconds.
Check all power doors are unlocked.
But if any door is not opened within 30 seconds after power
door(s) unlocked, all power doors are locked again automatical-
ly.
If check result of Step 1) to Step 3) is satisfactory, this operation is
OK.
HAZARD WARNING LIGHTS OPERATION
INSPECTION
1) Check that hazard warning lights flash one time when power
doors are locked by pushing LOCK button on transmitter.
2) Check that hazard warning lights flash two times when power
door(s) is (are) unlocked by pushing UNLOCK button on trans-
mitter.
If check result of Step 1) and Step 2) is satisfactory, this operation
is OK.
Page 603 of 801

YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-15
1. Main fuse
2. Main relay
3. ECM/PCM
4. Immobilizer indicator lamp
(Vehicle not equipped with
monitor coupler) For G16 / J20 engine For H25 engine
G16 / J20 Engine
H25 Engine
TABLE B IMMOBILIZER INDICATOR LAMP CHECK
(IMMOBILIZER INDICATOR LAMP DOSE NOT LIGHT AT IGNITION
SWITCH ON)
STEPACTIONYESNO
11) Turn ignition switch ON.
Do other indicator / warning lights in
combination meter come ON?Go to Step 2.ªIGº fuse blown, main fuse blown,
ignition switch malfunction,
ªB / Wº circuit between ªIGº fuse
and combination meter or poor
coupler connection at
combination meter.
21) Turn ignition switch OFF and
disconnect connectors from ECM /
PCM.
2) Check for proper connection to ECM /
PCM at terminal E61-5 for G16 / J20
engine or E61-23 for H25 engine.
3) If OK, then using service wire, ground
terminal E61-5 for G16 / J20 engine or
E61-23 for H25 engine in connector
disconnected.
Does immobilizer indicator lamp turn on
at ignition switch ON?Substitute a known-
good ECM / PCM and
recheck.Bulb burned out or ª(b)º wire
circuit open.
Page 616 of 801

YH4
GRAND
VITARA
8G-28 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
1
1. Ignition key with built-in transponder 1. Data link connector (DLC)
HOW TO REGISTER IGNITION KEY
Register the ignition key with a built-in transponder in Immobilizer
Control Module by using the following procedure.
1) Prepare Suzuki scan tool (TECH 1A kit and cartridge for immobi-
lizer control system).
2) With ignition switch OFF, connect Suzuki scan tool to data link
connector (DLC) located on underside of instrument panel at
driver's seat side.
Special Tool
(A): 09931-76011 (Tech 1A)
(B): Immobilizer cartridge
(C): 09931-76030 (16 / 14-pin DLC cable)
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator's manual.
3) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
4) Number of Transponder codes for ignition key with a built-in
transponder that can be registered in Immobilizer Control Mod-
ule is limited to 4. If needed, clear all Transponder codes for igni-
tion key with a built-in transponder that have been registered in
Immobilizer Control Module by executing the ªCLR. TRANS
COD (CLEAR TP CODE)º command in the SELECT MODE
menu by using Suzuki scan tool.
NOTE:
When ªCLR. TRANS COD (CLEAR TP CODE)º command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicle not equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
5) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing ªENT. TRANS COD (ENT. TP
CODE)º command in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
Page 617 of 801

YH4
GRAND
VITARA
IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED) 8G-29
7) If any other Transponder code for ignition key with a built-in
transponder needs to be registered, repeat above Steps 3), 5)
and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
PROCEDURE AFTER IMMOBILIZER
CONTROL MODULE REPLACEMENT
When Immobilizer Control Module was replaced, including when
replaced because rechecking by using a known-good Immobilizer
Control Module was necessary during trouble diagnosis, register
Transponder code and ECM / Immobilizer Control Module code in
Immobilizer Control Module and ECM / Immobilizer Control Module
code in ECM/PCM by performing following procedure.
1) Perform Steps 1) and 2) described in ªHow to register ignition
keyº section.
2) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
3) Using Suzuki scan tool, clear all transponder codes registered
in Immobilizer Control Module by executing ªCLR. TRANS COD
(CLEAR TP CODE)º command in SELECT MODE menu.
NOTE:
When ªCLR. TRANS COD (CLEAR TP CODE)º command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicles not
equipped with the monitor coupler) ON, it remains ON even
after execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
4) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing ªENT. TRANS COD (ENT. TP
CODE)º command in SELECT MODE menu.
5) Using Suzuki scan tool, register ECM / Immobilizer Control Mod-
ule code in both Immobilizer Control Module and ECM / PCM by
executing ªRECORD ECU (RECORD ECM / PCM / ICM)º com-
mand in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
7) If any other Transponder code for ignition key with a built-in trans-
ponder needs to be registered, repeat above Steps 2), 4) and 6).
NOTE:
Up to 4 Transponder codes for ignition key with a built-in
transponder can be registered.
It is not possible to register the same Transponder code
for ignition key with a built-in transponder as the one al-
ready registered in Immobilizer Control Module.
Page 618 of 801

YH4
GRAND
VITARA
8G-30 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
09931-76030
16 / 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)1. Storage case
2. Operator's manual
3. Tech 1A
4. DLC cable
(14 / 26 pin, 09931-76040)
5. Test lead/probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version1.5 or more
PROCEDURE AFTER ECM / PCM
REPLACEMENT
When ECM / PCM was replaced, including when replaced because
rechecking by using a known-good ECM / PCM was necessary dur-
ing trouble diagnosis, register ECM/Immobilizer Control Module
code in ECM / PCM by performing following procedure.
1) Perform Steps 1) and 2) described in ªHow to register ignition
keyº section. And then turn ignition switch ON.
2) Using TECH1, register ECM/Immobilizer Control Module code in
ECM / PCM by executing ªRECORD ECU (RECORD ECM / PCM/
ICM)º command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to TECH1
operator's manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS