Page 728 of 801

YH4
GRAND
VITARA
1. From main fuse
2. Ignition switch
3. ªIG
.COIL METERº fuse in J/B
4. ªAIR BAGº warning lamp in combination lamp
5. ªAIR BAGº fuse in ªAIR BAGº fuse box6. DLC
7. To, ICM (if equipped)
8. Connection detection pin
9. SDM
9-1. ªAIR BAGº warning lamp driver circuit : Air bag harness
10B-22 AIR BAG SYSTEM
TABLE D ± SDM CANNOT COMMUNICATE THROUGH THE SERIAL DATA CIRCUIT
(Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
STEPACTIONYESNO
11) Make sure that scan tool (Tech 1) is free
from malfunction and correct cartridge for
air bag system is used.
2) Ignition switch OFF.
3) Check proper connection of scan tool
(Tech 1) to DLC.
4) Is connection in good condition?Go to step 2 on
next page.Properly connect scan
tool to DLC.
Page 736 of 801

YH4
GRAND
VITARA
1. From ignition switch
2. ªAIR BAGº fuse in ªAIR BAGº fuse box
3. SDM
4. Passenger air bag (inflator) module: Shorting bar
: Air bag harness
10B-30 AIR BAG SYSTEM
CODE 19 ± PASSENGER AIR BAG INITIATOR CIRCUIT SHORT TO POWER CIRCUIT
(Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The voltage measured at passenger air bag initiator circuit is above a specified value for specified time.
Page 744 of 801

YH4
GRAND
VITARA
: Shorting bar
: Air bag harness
1. From ignition switch
2. ªAIR BAGº fuse in ªAIR BAGº fuse box
3. SDM
4. Contact coil assembly
5. Driver air bag (inflator) module
10B-38 AIR BAG SYSTEM
CODE 25 ± DRIVER AIR BAG INITIATOR CIRCUIT SHORT TO POWER CIRCUIT (Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The voltage measured at driver air bag initiator circuit is above a specified value for specified time.
NOTE:
Before executing items in this table, be sure to perform ªAir Bag Diagnostic Check Flow Tableº.
STEP
ACTIONYESNO
11) With ignition switch OFF, disconnect contact
coil connector located near the base of the
steering column.
2) Check proper connection to contact coil at
terminals in ªCº connector.
3) If OK then connect Special Tool (B) to contact
coil connector disconnected at step 1).
4) With ignition switch ON, is DTC 25 current?Go to step 2.Go to step 3 on the
next page.
21) With ignition switch OFF, disconnect Special
Tool (B) and SDM.
2) Measure voltage from ªA7º terminal to body
ground.
3) With ignition switch ON, is voltage 1 V or less?Substitute a known-
good SDM and
recheck.Repair short from ªGº or
ªG/Rº wire circuit to
power circuit.
Page 746 of 801

YH4
GRAND
VITARA
: Air bag harness
1. From main fuse
2. Ignition switch
3. ªAIR BAGº fuse in ªAIR BAGº fuse box
4. SDM
10B-40 AIR BAG SYSTEM
CODE 31 ± POWER SOURCE VOLTAGE HIGH (Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The power source voltage to SDM is above specified value for specified time.
Page 748 of 801

YH4
GRAND
VITARA
1. From main fuse
2. Ignition switch
3. ªAIR BAGº fuse in ªAIR BAGº fuse box
4. SDM : Air bag harness
10B-42 AIR BAG SYSTEM
CODE 32 ± POWER SOURCE VOLTAGE LOW (Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The power source voltage is below an approx. 8 V for specified time.
Page 749 of 801

YH4
GRAND
VITARA
(A)
AIR BAG SYSTEM 10B-43
CODE 32 ± POWER SOURCE VOLTAGE LOW (Page 2 of 2)
NOTE:
Before executing items in this table, be sure to perform ªAir Bag Diagnostic Check Flow Tableº.
STEP
ACTIONYESNO
11) Measure voltage on battery.
2) Is voltage 11 V or more?Go to step 2.Check Charging System
and repair as necessary.
(Refer to SECTION 6H
ªChanging Systemº)
21) With ignition switch OFF, disconnect SDM.
2) Check proper connection to SDM at ªA16º
terminal.
3) If OK then ignition switch ON, and then check
voltage from ªA16º terminal on SDM harness
connector to body ground.
4) Is voltage 8 V or more?Go to step 4.Go to step 3.
31) With ignition switch OFF, disconnect ignition
connector (ªFº connector) in air bag harness.
2) Check proper connection at terminal in ªFº
connector.
3) If OK then ignition switch ON, and then check
voltage from terminal in ªFº connector on main
harness to body ground.
4) Is voltage 8 V or more?Repair poor connec-
tion, high resistance
in ªBI/Rº or ªBI/Bº
circuit of air bag
harness or
ªAIR BAGº fuse.Possibly faulty points are
as follows. Check each of
them and repair as
necessary.
Circuit from battery to
ªFº connector
Charging System
(Refer to SECTION
6H ªChanging Systemº)
41) With ignition switch OFF, reconnect SDM
2) With ignition switch ON, is DTC 32 current?Substitute a known-
good SDM and
recheck.Check Charging System
and repair as necessary.
(Refer to SECTION 6H
ªChanging Systemº)
Fig. for STEP 2
Special Tool
(A): 09932-76010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Clear diagnostic trouble codes (refer to ªDiagnostic Trouble Code (DTC) Clearanceº), if any.
3) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.
Page 756 of 801

YH4
GRAND
VITARA
1. From ignition switch
2. ªAIR BAGº fuse in ªAIR BAGº fuse box
3. SDM
4. Passenger seat belt pretensioner
5. Driver seat belt pretensioner : Shorting bar
: Air bag harness
10B-50 AIR BAG SYSTEM
CODE 44 ± DRIVER PRETENSIONER INITIATOR CIRCUIT SHORT TO POWER CIRCUIT
CODE 48 ± PASSENGER PRETENSIONER INITIATOR CIRCUIT SHORT TO POWER CIRCUIT
(Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The voltage measured at driver or passenger seat belt pretensioner initiator circuit is above a specified value for
specified time.
Page 759 of 801

YH4
GRAND
VITARA
1. From main fuse
2. Ignition switch
3. ªIG
.COIL METERº fuse in J/B7. Connection detection pin
8. SDM
8-1. ªAIR BAGº warning lamp driver circuit 4. ªAIR BAGº warning lamp in combination meter
5. ªAIR BAGº fuse in ªAIR BAGº fuse box
6. ªAIR BAGº monitor coupler : Air bag harness
AIR BAG SYSTEM 10B-53
CODE 61 ± ªAIR BAGº WARNING LAMP CIRCUIT FAILURE (Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
DTC WILL SET WHEN:
The voltage at the ªAIR BAGº warning lamp circuit terminal ªA5º does not match the commanded state of the warn-
ing lamp driver for specified time.
Page 761 of 801

YH4
GRAND
VITARA
AIR BAG SYSTEM 10B-55
ON-VEHICLE SERVICE
SERVICE PRECAUTIONS
SERVICE AND DIAGNOSIS
WARNING/CAUTION labels are attached on each part of air bag system components (SDM, air bag (inflator) mod-
ules and seat belt pretensioners). Be sure to follow the instructions.
WARNING:
If the air bag system and another vehicle system both need repair, Suzuki recommends that the air
bag system be repaired first, to help avoid unintended air bag system activation.
Do not modify the steering wheel, dashboard or any other air bag system components. Modifications
can adversely affect air bag system performance and lead to injury.
Failure to follow procedures could result in possible air bag system activation, personal injury or un-
needed air bag system repairs.
Many of service procedures require disconnection of ªAIR BAGº fuse and air bag (inflator) modules (driver and
passenger) from initiator circuit to avoid an accidental deployment.
Do not apply power to the air bag system unless all components are connected or a diagnostic chart requests
it, as this will set a diagnostic trouble code.
The ªAir Bag Diagnostic System Checkº must be the starting point of any air bag diagnostics. The ªAir Bag Diag-
nostic System Checkº will verify proper ªAIR BAGº warning lamp operation and will lead you to the correct chart
to diagnose any air bag malfunctions. Bypassing these procedures may result in extended diagnostic time, incor-
rect diagnosis, and incorrect parts replacements.
Never use air bag component parts from another vehicle.
If the vehicle will be exposed to temperatures over 93C (200F) (for example, during a paint baking process),
remove the air bag system components beforehand to avoid component damage or unintended system activa-
tion.
When servicing, if shocks may be applied (eg., dropped from a height of 90 cm (3 ft) or more) to air bag system
component parts, remove those parts beforehand.
When using electric welding, be sure to disconnect air bag (inflator) module and seat belt pretensioner connec-
tors (driver and passenger) respectively.
When applying paint around the air bag system related parts, use care so that the harness or connector will not
be exposed to the paint mist.
Never expose air bag system component parts directly to hot air (drying or baking the vehicle after painting) or
flames.
WARNING:
When performing service on or around air bag system components or air bag wiring, follow the proce-
dures listed in the following pages to temporarily disable the air bag system. Refer to appropriate ser-
vice manual procedures. Failure to follow procedures could result in possible air bag system activa-
tion, personal injury or unneeded air bag system repairs.
Page 762 of 801

YH4
GRAND
VITARA
1. Air bag harness
2. ªAIR BAGº monitor coupler
3. Yellow connector of contact coil and combination
switch assembly
4. Yellow connector of passenger air bag (inflator) module
5. Steering support member
1. Air bag harness
2. ªAIR BAGº monitor coupler
3. Yellow connector of contact coil and combination
switch assembly
10B-56 AIR BAG SYSTEM
DISABLING AIR BAG SYSTEM
1) Turn steering wheel so that vehicle's wheels (front tires) and
pointing straight ahead.
2) Turn ignition switch to ªLOCKº position and remove key.
3) Remove ªAIR BAGº fuse from ªAIR BAGº fuse box.
4) Disconnect Yellow connector of contact coil and combination
switch assembly.
ii) Release locking of lock lever.
ii) After unlocked, disconnect to connector.
5) Pull out glove box while pushing its stopper from both right and
left sides and disconnect Yellow connector of passenger air bag
(inflator) module.
ii) Release locking of lock lever.
ii) After unlocked, disconnect to connector.
NOTE:
With ªAIR BAGº fuse removed and ignition switch ON, ªAIR
BAGº warning lamp will be ON.
This is normal operation and does not indicate an air bag
system malfunction.
ENABLING AIR BAG SYSTEM
1) Turn ignition switch to ªLOCKº and remove key.
2) Connect Yellow connector of contact coil and combination
switch assembly, and be sure to lock connector with lock lever.
ii) Connect connector.
ii) Lock connector with lock lever.