dlc SUZUKI GRAND VITARA 2004 2.G Service Owner's Manual
[x] Cancel search | Manufacturer: SUZUKI, Model Year: 2004, Model line: GRAND VITARA, Model: SUZUKI GRAND VITARA 2004 2.GPages: 801, PDF Size: 12.15 MB
Page 610 of 801

YH4
GRAND
VITARA
8G-22 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
A812
To SDM (if equipped with AIRBAG)
To data link connector (DLC)1. Immobilizer Control Module
2. ECM / PCM (j) (i)
(i)
(i)
DTC23 NO ECM/IMMOBILIZER CONTROL MODULE CODE TRANSMITTED
FROM ECM/PCM OR DLC CIRCUIT OPENED/SHORTED
DTC83 NO ECM/IMMOBILIZER CONTROL MODULE CODE TRANSMITTED
(P1621) FROM IMMOBILIZER CONTROL MODULE OR DLC CIRCUIT
OPENED/SHORTED
DESCRIPTION
When the ignition switch is ON, Immobilizer Control Module requests ECM / PCM and ECM / PCM requests Immobi-
lizer Control Module to transmit ECM/Immobilizer Control Module code. If ECM/Immobilizer Control Module code
is not transmitted from ECM / PCM or Immobilizer Control Module, Immobilizer Control Module sets DTC23 and
ECM / PCM sets DTC83 (P1621).
INSPECTION:
STEPACTIONYESNO
1Check voltage between
Immobilizer Control Mod-
ule coupler terminal A8
and body ground with igni-
tion switch turned ON.
Is it 4 ± 5V?Go to Step 2.ª(i)º or ª(j)º wire
short.
21) Disconnect ECM /
PCM coupler with igni-
tion switch turned
OFF.
2) Is there continuity be-
tween Immobilizer
Control Module cou-
pler terminal A8 and
Data link connector
terminal of ECM / PCM
coupler? (For posi-
tions of Data link con-
nector terminal of
ECM / PCM coupler,
refer to Section 6E1 or
6E2.)Poor A8 connection (Immobilizer Control Module) or
Poor Data link connector terminal connection (ECM /
PCM). If connections are OK, substitute a known-good
ECM / PCM or Immobilizer Control Module and re-
check.
NOTE :
After replacing with a known-good ECM / PCM,
register ECM/Immobilizer Control Module code
in ECM / PCM by performing procedure de-
scribed in ªProcedure after ECM / PCM Replace-
mentº section.
After replacing with a known-good Immobilizer
Control Module, register ECM/Immobilizer Control
Module code in ECM / PCM and Transponder code
and ECM/Immobilizer Control Module code in Im-
mobilizer Control Module by performing proce-
dure described in ªProcedure after Immobilizer
Control Module Replacementº section.ª(i)º or ª(j)º wire be-
tween Immobilizer
Control Module and
ECM / PCM open.
Fig. 1 for step 1
1
A8
1. Immobilizer Control Module
1. Immobilizer Control Module coupler disconnected1
A8Connect to Data link connector terminal
of ECM / PCM coupler disconnected
Fig. 2 for step 2
Page 616 of 801

YH4
GRAND
VITARA
8G-28 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
1
1. Ignition key with built-in transponder 1. Data link connector (DLC)
HOW TO REGISTER IGNITION KEY
Register the ignition key with a built-in transponder in Immobilizer
Control Module by using the following procedure.
1) Prepare Suzuki scan tool (TECH 1A kit and cartridge for immobi-
lizer control system).
2) With ignition switch OFF, connect Suzuki scan tool to data link
connector (DLC) located on underside of instrument panel at
driver's seat side.
Special Tool
(A): 09931-76011 (Tech 1A)
(B): Immobilizer cartridge
(C): 09931-76030 (16 / 14-pin DLC cable)
NOTE:
For operation procedure of Suzuki scan tool, refer to Suzuki
scan tool operator's manual.
3) Prepare ignition key with a built-in transponder. And then turn
ignition switch ON by using it.
4) Number of Transponder codes for ignition key with a built-in
transponder that can be registered in Immobilizer Control Mod-
ule is limited to 4. If needed, clear all Transponder codes for igni-
tion key with a built-in transponder that have been registered in
Immobilizer Control Module by executing the ªCLR. TRANS
COD (CLEAR TP CODE)º command in the SELECT MODE
menu by using Suzuki scan tool.
NOTE:
When ªCLR. TRANS COD (CLEAR TP CODE)º command is
executed with the malfunction indicator lamp (the lamp for
vehicles equipped with the monitor coupler) ON or the im-
mobilizer indicator lamp (the lamp for vehicle not equipped
with the monitor coupler) ON, it remains ON even after
execution of that command is over. It will start flashing
when the ignition switch is turned OFF once and then
turned ON after some seconds.
5) Using Suzuki scan tool, register Transponder code in Immobiliz-
er Control Module by executing ªENT. TRANS COD (ENT. TP
CODE)º command in SELECT MODE menu.
6) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
Page 618 of 801

YH4
GRAND
VITARA
8G-30 IMMOBILIZER CONTROL SYSTEM (IF EQUIPPED)
09931-76030
16 / 14 pin DLC cable
09931-76011
Suzuki scan tool (Tech 1A kit)1. Storage case
2. Operator's manual
3. Tech 1A
4. DLC cable
(14 / 26 pin, 09931-76040)
5. Test lead/probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter
Immobilizer cartridge of
version 1.1 or more
NOTE:
Use this cable only with im-
mobilizer cartridge of ver-
sion 1.1 or more.
Use of this cable with 96
immobilizer cartridge will
disable 96 immobilizer car-
tridge from operating prop-
erly.
Mass storage cartridge of
version1.5 or more
PROCEDURE AFTER ECM / PCM
REPLACEMENT
When ECM / PCM was replaced, including when replaced because
rechecking by using a known-good ECM / PCM was necessary dur-
ing trouble diagnosis, register ECM/Immobilizer Control Module
code in ECM / PCM by performing following procedure.
1) Perform Steps 1) and 2) described in ªHow to register ignition
keyº section. And then turn ignition switch ON.
2) Using TECH1, register ECM/Immobilizer Control Module code in
ECM / PCM by executing ªRECORD ECU (RECORD ECM / PCM/
ICM)º command in SELECT MODE menu.
NOTE:
For operation procedure of Suzuki scan tool, refer to TECH1
operator's manual.
3) [Vehicle equipped with monitor coupler]
Make sure that malfunction indicator lamp lights when ignition
switch is turned OFF once and then ON.
[Vehicle not equipped with monitor coupler]
Make sure that immobilizer indicator lamp lights when ignition
switch is turned OFF once and then ON.
SPECIAL TOOLS
Page 710 of 801

YH4
GRAND
VITARA
10B-4 AIR BAG SYSTEM
1. Air bag harness
2. ªAIR BAGº fuse box
3. ªAIR BAGº monitor coupler
4. DLC
5. Contact coil assembly
6. Driver air bag (inflator) module
7. Passenger air bag (inflator) module
8. SDM
9. Seat belt pretensioner
(retractor assembly) (if equipped)
10. Pretensioner harness (if equipped)
11. Ground for air bag systemCONNECTOR ªAº
CONNECTOR ªCº, ªDº
CONNECTOR ªBº
CONNECTOR ªEº
CONNECTOR ªHº
CONNECTOR ªFº
CONNECTOR ªGº
SYSTEM COMPONENTS AND WIRING LOCATION VIEW AND CONNECTORS
Page 711 of 801

YH4
GRAND
VITARA
WIRE HARNESS COLOR
B : Black
B/W : Black/White
Bl : Blue
Bl/B : Blue/Black
Bl/R : Blue/Red
Br : BrownG : Green
Gr : Gray
G/R : Green/Red
Lg : Lightgreen
P : Pink
V : VioletY : Yellow
Y / G : Yellow/Green
Y/R : Yellow/Red
W : White
W/B : White/Black
1. From main fuse
2. Ignition switch
3. ªIG
.COIL METERº fuse in J/B
4. ªAIR BAGº warning lamp in combination meter
5. ªAIR BAGº fuse in ªAIR BAGº fuse box
6. Connection detection pin
7. To ECM (or PCM), ICM (if equipped) and ABS
controller (if equipped)
8. To data link connector (DLC)
9. ªAIR BAGº monitor coupler
10. SDM
11. Contact coil assembly
12. Driver air bag (inflator) module
13. Driver seat belt pretensioner (if equipped)
14. Passenger air bag (inflator) module
15. Passenger seat belt pretensioner (if equipped)
16. Pretensioner harness (if equipped)
17. Ground for air bag system
TERMINAL
A1
A2
A3
A4
A5
A6
A7
A8
A9
A10
A13 A11
A12
A14
A15
A16
Passenger air bag (inflator) moduleLow
High
CIRCUIT
Data link connector (DLC)
Low
High
Low
High
Low
High ªAIR BAGº warning lamp
Driver air bag (inflator) module
Diagnosis switch
±±±±±±±±±
Ground
Passenger pretensioner
Driver pretensioner
Ignition switch (power source)±±±±±±±±±
±±±±±±±±±
CONNECTOR ªAº (SDM connector) TERMINAL ARRANGEMENT OF SDM
(VIEWED FROM HARNESS SIDE)
L1
L2Connection detection pin
: Shorting bar
: Air bag harness
ªAº ªHº : Connector
AIR BAG SYSTEM 10B-5
SYSTEM WIRING DIAGRAM
Page 718 of 801

YH4
GRAND
VITARA
10B-12 AIR BAG SYSTEM
1. Data link connector (DLC)
2. DLC cable adapter
3. DLC cable
-1. ªAIR BAGº
warning lamp
-2. ªAIR BAGº fuse box
-3. ªAIR BAGº
monitor coupler
3-1. Diagnostic switch
terminal
-4. Air bag harness
(covered yellow tube)
EXAMPLE: When driver air bag initiator circuit resistance high (Code No.21) is set
Malfunction indicator lamp
(ªAIR BAGº warning lamp)
Turn ON
Turn OFF
Time (sec.) Code No. 21 Code No. 21 Code No. 21 1
DIAGNOSTIC TROUBLE CODE (DTC) CHECK
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) After setting cartridge to Tech 1, connect it to data link connector
(DLC) located on underside of instrument panel at driver's seat
side.
Special Tool
(A): 09931-76011 (Tech 1)
(B): Mass storage cartridge
(C): 09931-76030
3) Turn ignition switch ON.
4) Read DTC according to instructions displayed on Tech 1 and
print it or write it down. Refer to Tech 1 operator's manual for fur-
ther details.
5) After completing the check, turn ignition switch OFF and discon-
nect Tech 1 from data link connector (DLC).
[Not using SUZUKI scan tool]
1) Check that malfunction indicator lamp (ªAIR BAGº warning
lamp) comes ON when ignition switch is turned ON.
If it does not come ªONº, proceed to ªTable Bº on p.10B-18.
2) Using service wire, ground diagnosis switch terminal in monitor
coupler.
3) Read DTC from flashing pattern of malfunction indicator lamp
(ªAIR BAGº warning lamp). (Refer to ªDiagnostic Trouble Code
Tableº on p.10B-14 and 10B-15.)
4) After completing the check, turn ignition switch OFF and discon-
nect service wire from ªAIR BAGº monitor coupler.
Page 719 of 801

YH4
GRAND
VITARA
1. Data link connector
2. DLC cable adapter
3. DLC cable
1sec. 1sec.About 10 seconds
Open
Short-1. ªAIR BAGº warning lamp
-2. ªAIR BAGº fuse box
-3. ªAIR BAGº monitor coupler
3-1. Diagnostic switch terminal
-4. Air bag harness (covered yellow tube)1
AIR BAG SYSTEM 10B-13
DIAGNOSTIC TROUBLE CODE (DTC) CLEARANCE
[Using SUZUKI scan tool]
1) Turn ignition switch OFF.
2) Connect Tech 1 to data link connector (DLC) in the same manner
as when making this connection for DTC check.
Special Tool
(A): 09931-76011 (Tech 1)
(B): Mass storage cartridge
(C): 09931-76030
3) Turn ignition switch ON.
4) Erase DTC according to instructions displayed on Tech 1.
Refer to Tech 1 operator's manual for further details.
5) After completing the check, turn ignition switch OFF and discon-
nect Tech 1 from data link connector (DLC).
6) Perform ªDiagnosis Trouble Code (DTC) Checkº and confirm
that normal DTC (NO CODES) is displayed and not malfunction
DTC.
NOTE:
If DTC 51 or DTC 71 is stored in SDM, it is not possible to
clear DTC.
[Not using SUZUKI scan tool]
1) Turn ignition switch ON and wait about 6 seconds or more.
2) Using service wire, repeat shorting and opening between diag-
nosis switch terminal and ground terminal on ªAIR BAGº monitor
coupler 5 times at about 1 second intervals.
3) Perform ªDiagnosis Trouble Code (DTC) Checkº and confirm
that normal DTC (DTC 12) is displayed and not malfunction
DTC.
NOTE:
If DTC 51 or DTC 71 is stored in SDM, it is not possible to
clear DTC.
Page 728 of 801

YH4
GRAND
VITARA
1. From main fuse
2. Ignition switch
3. ªIG
.COIL METERº fuse in J/B
4. ªAIR BAGº warning lamp in combination lamp
5. ªAIR BAGº fuse in ªAIR BAGº fuse box6. DLC
7. To, ICM (if equipped)
8. Connection detection pin
9. SDM
9-1. ªAIR BAGº warning lamp driver circuit : Air bag harness
10B-22 AIR BAG SYSTEM
TABLE D ± SDM CANNOT COMMUNICATE THROUGH THE SERIAL DATA CIRCUIT
(Page 1 of 2)
CAUTION:
When measurements are requested in this chart use specified digital multimeter with correct terminal
adapter from special tool (Connector test adapter kit).
When a check for proper connection is requested refer to ªIntermittent and Poor Connectionsº in this
section.
When an open in air bag wire harness, damaged wire harness, connector or terminal is found, replace
wire harness, connectors and terminals as an assembly.
STEPACTIONYESNO
11) Make sure that scan tool (Tech 1) is free
from malfunction and correct cartridge for
air bag system is used.
2) Ignition switch OFF.
3) Check proper connection of scan tool
(Tech 1) to DLC.
4) Is connection in good condition?Go to step 2 on
next page.Properly connect scan
tool to DLC.
Page 729 of 801

YH4
GRAND
VITARA
1. DLC
2. Scan tool1. ªW/Bº wire terminal
AIR BAG SYSTEM 10B-23
TABLE D ± SDM CANNOT COMMUNICATE THROUGH THE SERIAL DATA CIRCUIT
(Page 2 of 2)
STEPACTIONYESNO
21) Check if communication is possible by
trying communication with other
controller (ECM (or PCM), ICM or ABS
controller).
2) Is it possible to communicate with other
controller?Go to step 3.Repair open in common
section of serial data circuit
(ªW/Bº wire circuit) used by
all controllers or short to
ground or power circuit
which has occurred some-
where in serial data circuit
(ªW/Bº wire circuit).
31) With ignition switch OFF, disconnect
SDM and ªLamp, DLC and Monitor
Coupler Groundº (ªEº) connector.
2) Check proper connection at ªW/Bº wire
terminal for DLC in ªEº connector.
3) If OK, then check resistance between
ªW/Bº wire terminal in ªEº connector and
ªA4º terminal of SDM connector.
4) Is resistance 1 or less?Substitute a known-good
SDM and recheck.Repair high resistance or
open in ªW/Bº wire circuit
(in air bag harness).
Fig. for STEP 1 Fig. for STEP 3
Special Tool
(A): 09932-76010
NOTE:
Upon completion of inspection and repair work, perform following items.
1) Reconnect all air bag system components, ensure all components are properly mounted.
2) Repeat ªAir Bag Diagnostic System Check Flow Tableº, referring to p.10B-11 to confirm that the trouble
has been corrected.
Page 801 of 801

YH4
GRAND
VITARA
AIR BAG SYSTEM 10B-95
09931-76011
Suzuki scan tool (tech 1A) kit1. Storage case
2. Operator's manual
3. Tech 1A
4. DLC cable
5. Test lead/probe
6. Power source cable
7. DLC cable adapter
8. Self-test adapter Mass storage cartridge for air bag system
09931-76030
16/14 pin DLC cable09932-75010
Air bag driver/passenger
load tool09932-76010
Connector test adapter kit09932-75030
Air bag deployment harness
09932-75040
Passenger air bag (inflator)
module deployment fixtureDigital multimeter for
which the maximum test
current is 10 mA or less
at the minimum range of
resistance measurement.
WARNING:
Be sure to use the specified
digital multimeter.
Otherwise, air bag deploy-
ment or personal injury may
result.
TIGHTENING TORQUE SPECIFICATIONS
FasteningpartsTightening torqueFastening artsN.mkg-mlb-ft
SDM bolt60.64.5
Passenger air bag (inflator) modulescrew5.50.554.0Passenger air bag (inflator) modulebolt232.316.5
Driver air bag (inflator) module boltRefer to SECTION 3C1.
Seat belt pretensioner (retractor assembly) boltRefer to SECTION 10A.
SPECIAL TOOLS