Valve SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual SWIFT 2000 1.G SUZUKI SUZUKI https://www.carmanualsonline.info/img/20/7602/w960_7602-0.png SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual

Page 333 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual A: Timing belt side
B: Flywheel side
6A1-38 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
INSTALLATION
1) Apply engine oil to rocker arm shaft and rocker arms.
2) Check O-ring for damage or deterio

Page 334 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE) 6A1-39
Indicates position from timing
belt side. Install in numerical
order starting from timing belt
side.
Indicates direction of housing.
Install s

Page 335 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 6A1-40 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
1. O-ring2
10) Using special tool, tighten pulley bolt to specified torque.
Tightening Torque
(a): 60 N
.m (6.0 kg-m, 43.5 lb-ft)
Special Tool
(

Page 336 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual : Do not reuse
1. Valve cotters
2. Valve spring retainer
3. Valve spring:
be sure to position
spring in place with its
bottom end (small-pitch
end) facing the bottom
(valve spring seat side).
4. Valve

Page 337 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 6A1-42 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
Ignition coil assembly
Ground wires from 
intake manifold
EVAP canister purge
valve
ECT sensorInjectors, TP sensor and
IAC valve wires at t

Page 338 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 3
2. Breather hose
3. PCV valve4. High-tension cords
5. Ignition coil assembly
6. Ignition coil coupler
A: Camshaft pulley side
B: CMP sensor case side
ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)

Page 339 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 6A1-44 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
DISASSEMBLY
1) For ease in servicing cylinder head, remove CMP sensor case,
intake manifold with throttle body and exhaust manifold from cyl-
in

Page 340 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE) 6A1-45
INSPECTION
Valve Guides
Using a micrometer and bore gauge, take diameter readings on
valve stems and guides to check stem-to-guide clearance.
Be

Page 341 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual 6A1-46 ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE)
Inspect valve stem end face for pitting and wear. If pitting or wear
is found there, valve stem end may be resurfaced, but not so
much as to gr

Page 342 of 557

SUZUKI SWIFT 2000 1.G SF310 Service Workshop Manual ENGINE MECHANICAL (G13B, 1-CAM 16-VALVES ENGINE) 6A1-47
Valve seat repair:
A valve seat (2) not producing a uniform contact with its valve or
showing width of seating contact that is out of specified