1. Pickup coil
2. Signal rotor
3. Screws
1. Distributor
2. Coupler
3. Ohmmeter
6F-8 IGNITION SYSTEM
DISTRIBUTOR
DISTRIBUTOR CAP AND ROTOR
INSPECTION
Check cap and rotor for crack and their terminals for corrosion and
wear. Replace as necessary.
SIGNAL ROTOR AIR GAP
INSPECTION
1) Remove distributor cap and rotor.
2) Using thickness gauge, measure air gap, between signal rotor
tooth and CMP sensor (generator).
Signal rotor air gap “a”: About 0.2 mm (about 0.008 in.)
3) If gap is out of specification, loose CMP sensor (signal genera-
tor) securing screws. Using blade (–) screw driver, move CMP
sensor (generator) and adjust gap to specification. After adjust-
ment, tighten securing screws and recheck gap.
NOTE:
Check to make sure that CMP sensor (signal generator)
tooth is free from any metal particles.
4) Install distributor cap and rotor.
CMP SENSOR (PICKUP COIL) RESISTANCE
INSPECTION
1) Disconnect distributor lead coupler.
2) Measure resistance of pickup coil by using ohmmeter.
3) If resistance is out of specification, replace CMP sensor (signal
generator) as follows.
Pickup coil resistance:
185 – 275 Ω at – 10C (14F) – 50C (122F)
240 – 325 Ω at 50C (122F) – 100C (212F)
4) Remove distributor cap and rotor.
5) Remove CMP sensor (signal generator) securing screws and
lead wire clamp screws.
6) Replace CMP sensor (signal generator).
7) Adjust signal rotor air gap to specifications as previously out-
lined.
8) Install rotor, distributor cap seal and cap.
Page 477 of 557

1. Cap
2. Cap seal
3. Cap screw
4. Rotor
5. CMP sensor
(Signal generator)
6. Screw
7. Cover
8. Housing
9. O-ring
A: Slot offset
1. Distributor case
2. O-ring3. Distributor coupling
4. Camshaft
6F-10 IGNITION SYSTEM
DISTRIBUTOR UNIT
DISMOUNTING
1) Disconnect distributor lead coupler.
2) Remove distributor cap screws and cap.
3) Remove distributor flange bolts.
4) Pull out distributor housing assembly.
REMOUNTING
NOTE:
Before installing distributor, check to make sure that its
O-ring is in good condition.
If new O-ring is installed, apply oil.
1) Install distributor without cap to camshaft.
Fit the dogs of distributor coupling into the slots of camshaft,
when installing. The dogs of distributor coupling are offset.
Therefore, if the dogs can not shaft by 180 degree and try again.
2) Lightly install flange bolts and prepare for ignition timing adjust-
ment.
3) Check to make sure that rotor is in good condition.
4) Inspect distributor cap and clean or replace as required.
5) Make sure that distributor cap seal is placed properly and install
cap, and then fasten it with screws.
6) Connect distributor lead coupler.
7) Check and adjust ignition timing as previously outlined.
Page 535 of 557

NOTE:
Terminal arrangement of coupler viewed from harness side.
Coupler A
1. To generator W / R
2. To ignition switch B / W
3. To ECM V / G
4. To ECM V
5. Blank –
6. To ECT sensor Y / W
7. Blank —
8. To engine oil pressure switch Y / B
9. To ECM Br
10. Blank —
11. To SDM (if equipped) Bl
12. Blank —
13. Blank —
14. Blank —
15. To ground R
16. To combination switch R / Y
Coupler B
1. To combination switch G / R
2. Blank —
3. Blank —
4. To ECM Y / G
5. To brake fluid level switch and R / B
parking brake switch
6. Blank —
7. To ABS control module R / Bl
(if equipped)
8. Blank —
9. To fuel level gauge Y / R
10. To ground B / Bl
11. To ignition switch B / W
12. Blank —
13. Blank —
Coupler C
1. Blank —
2. Blank —
3. Blank —
4. Blank —
5. Blank —
6. Blank —
7. To main fuse R
8. To combination switch W / Bl
9. To ground B
10. To combination switch G / Y
Coupler A Coupler B Coupler C