ring SUZUKI SWIFT 2007 2.G Service Workshop Manual

SUZUKI SWIFT 2007 2.G Service Workshop Manual SWIFT 2007 2.G SUZUKI SUZUKI https://www.carmanualsonline.info/img/20/7607/w960_7607-0.png SUZUKI SWIFT 2007 2.G Service Workshop Manual

Page 944 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-8 Heater and Ventilation: 
b. Move temperature control lever (1) and air flow control plate (2) fully to the arrow direction. c. Fix tempera

Page 945 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-9
Blower Speed Selector InspectionS7RS0B7106010
Check blower speed selector for each terminal to 
terminal continui

Page 946 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7A-10 Heater and Ventilation: 
Air Intake Control Actuator InspectionS7RS0B7106013
Check air intake control actuator as follows:1) Using servic

Page 947 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Heater and Ventilation:  7A-11
Side Ventilation Louver Removal and 
Installation
S7RS0B7106015
Driver side ventilation louver
Removal1) Disconn

Page 950 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7B-2 Air Conditioning System: Manual Type
Refrigerant Line
• Never use heat for bending pipes. When bending a pipe , try to make its bending

Page 954 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7B-6 Air Conditioning System: Manual Type
A/C System Wiring DiagramS7RS0B7212002
BLK/REDBLK/RED
BLK/YELBLK/YEL
BLK/YEL
BRN/WHT
12V5V
5V 5V
5V11

Page 955 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Air Conditioning System: Manual Type 7B-7
Diagnostic Information and Procedures
A/C System Symptom DiagnosisS7RS0B7214001
ConditionPossible cau

Page 956 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7B-8 Air Conditioning System: Manual Type
Cool air does not come 
out or insufficient cooling 
(A/C system normal 
operation)Insufficient or ex

Page 957 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine Air Conditioning System: Manual Type 7B-9
Abnormal Noise Symptom Diagnosis of A/C SystemS7RS0B7214002
Abnormal Noise from Compressor
Abnormal N

Page 958 of 1496

SUZUKI SWIFT 2007 2.G Service Workshop Manual Downloaded from www.Manualslib.com manuals search engine 7B-10 Air Conditioning System: Manual Type
Abnormal Noise from Tension Pulley
Abnormal Noise from A/C Evaporator
Abnormal Noise from Blower Mot