1. NORMALLY
OPENOpens and
closes circuits,
thereby
stopping (1) or
allowing (2)
current flow.
RESISTOR
An electrical component with a
fixed resistance, placed in a circuit
to reduce voltage to a specific
value.
RESISTOR, TAPPED
A resistor which supplies two or
more different non adjustable
resistance values.
SENSOR (Thermistor)
A resistor which varies its
resistance with temperature.
SHORT PIN
Used to provide an unbroken
connection within a junction block.
SOLENOID
An electromagnetic coil which
forms a magnetic field when
current flows, to move a plunger,
etc.SWITCH, DOUBLE THROW
A switch which continuously
passes current through one set
of contacts or the other.
SWITCH,
IGNITION
A key operated switch with
several positions which allows
various circuits, particularly the
primary ignition circuit, to
become operational.
Wires are always
drawn as straight lines
on wiring diagrams.
Crossed wires (1)
without a black dot at
the junction are not
joined; crossed wires
(2) with a black dot or
octagonal (
) mark at
the junction are spliced
(joined) connections. RELAY, DOUBLE THROW
A relay which passes current
through one set of contacts or the
other.
SENSOR, ANALOG SPEED
Uses magnetic impulses to open
and close a switch to create a
signal for activation of other
components.TRANSISTOR
A solidstate device typically used
as an electronic relay; stops or
passes current depending on the
voltage applied at ªbase.º SWITCH, WIPER PARK
Automatically returns wipers to
the stop position when the wiper
switch is turned off. SWITCH, MANUAL SPEAKER
An electromechanical device
which creates sound waves from
current flow.
2. NORMALLY
CLOSED
RESISTOR, VARIABLE or
RHEOSTAT
A controllable resistor with a
variable rate of resistance.
Also called a potentiometer or
rheostat. 2. NORMALLY
OPEN RELAY
1. NORMALLY
CLOSEDBasically, an electrically
operated switch which may
be normally closed (1) or
open (2).
Current flow through a
small coil creates a
magnetic field which either
opens or closes an
attached switch.
(2) SPLICED WIRES
(1) NOT
CONNECTED
Page 243 of 307

243
FAN MOTOR OPERATION
WITH THE IGNITION SW IS TURNED ON, CURRENT FLOWS FROM ECU±IG FUSE TO RADIATOR FAN RELAY NO. 1 (COIL SIDE) AND
RADIATOR FAN RELAY NO. 2 (COIL SIDE) " TERMINAL 2 OF THE A/C SINGLE PRESSURE SW " TERMINAL 3 " TERMINAL 2 OF THE
WATER TEMP. SW " TERMINAL 1 " GROUND, AND RADIATOR FAN RELAY NO. 1 AND NO. 2 ARE TURNED ON.
*RADIATOR FAN MOTOR OPERATION
WHEN THE IGNITION SW IS TURNED ON, RADIATOR FAN RELAY NO. 1 IS TURNED ON. IF AT THIS TIME THE ENGINE COOLANT
TEMPERATURE IS APPROX. 90°C (194°F) OR HIGHER, THE WATER TEMP. SW IS TURNED OFF, RADIATOR FAN RELAY NO. 1 IS
TURNED OFF.
AS A RESULT, CURRENT FROM THE RDI FAN FUSE TO RADIATOR FAN RELAY NO. 1 (POINT SIDE) " TERMINAL 2 OF THE
RADIATOR FAN MOTOR " TERMINAL 1 " GROUND, THUS ACTIVATING THE ROTATION OF THE RADIATOR FAN MOTOR.
*LOW SPEED OPERATION
WHEN THE IGNITION SW IS TURNED ON AND THE A/C ACTIVATED, RADIATOR FAN RELAY NO. 1 AND RADIATOR FAN RELAY NO. 2
ARE TURNED ON, CURRENT FLOWS FROM A/C MAGNETIC CLUTCH RELAY (POINT SIDE) TO RADIATOR FAN RELAY NO. 3 (COIL
SIDE) " GROUND, AND RADIATOR FAN RELAY NO. 3 IS TURNED ON.
AS A RESULT, CURRENT FLOWS FROM CDS FAN FUSE TO TERMINAL 2 OF THE A/C CONDENSER FAN MOTOR " TERMINAL 1 "
RADIAOTR FAN RELAY NO. 2 (POINT SIDE) " RADIATOR FAN RELAY NO. 3 (POINT SIDE) " TERMINAL 2 OF THE RADIATOR FAN
MOTOR " TERMINAL 1 " GROUND, FLOWING TO EACH FAN MOTOR IN SERIES, CAUSING THE FAN TO AT LOW SPEED.
*HIGH SPEED OPERATION OF THE FAN MOTOR DUARING A/C OPERATION
WHEN THE A/C OPERATION, THE REFRIGERRANT PRESSURE BECOME HIGHER THAN OR DINARY LEVEL (APPROX. 15.58 KG/CM
2
(221.2 PSI, 1527 KPA)) THE A/C SINGLE PRESSURE SW IS TURNED OFF. AS A RESULT, RADIATOR FAN RELAY NO. 1 AND RADIATOR
FAN RELAY NO. 2 ARE TURNED OFF, AND CURRENT FLOWS FROM RDI FUSE TO RADIATOR FAN RELAY NO. 1 (POINT SIDE) "
TERMINAL 2 OF THE RADIATOR FAN MOTOR " TERMINAL 1 " GROUND, AND CURRENT FLOWS FROM CDS FAN FUSE TO
TERMINAL 2 OF THE A/C CONDENSER FAN MOTOR " TERMINAL 1 " RADIATOR FAN RELAY NO. 2 (POINT SIDE) " GROUND, AND
TO EACH FAN MOTOR IN PARALLEL, THUS CAUSING THE FAN MOTORS OPERATE HIGH SPEED.
NOTE THAT, BECAUSE THE CURRENT FLOWS IN THE SAME MENNER EVEN IF THE ENGINE COOLANT TEMPERATURE IS APPROX.
90°C (194°F) OR HIGHER, THE FAN MOTOR OPERATE AT HIGH SPEED.
A 2 A/C SINGLE PRESSURE SW
2±3 : OPEN ABOVE APPROX. 15.58 KG/CM2 (221.2 PSI, 1527 KPA)
CLOSE BELOW APPROX. 15.56 KG/CM2 (178.4 PSI, 1231 KPA)
2 1
2 1 A1R1 BLACKGRAY
12E5 A2BLACK
23
SYSTEM OUTLINE
SERVICE HINTS