O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 24 of 43
CHART 18:
Rear O2S (Bank 1 Sensor 2) Voltage Monitor
Related DTCs: P0136
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.2 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.6 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 3) Deterioration Monitor
Related DTCs: P0142
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$86Average of the second
impedance ratio between high±
frequency and low±frequency
Multiply 0.0312%Between 0.7 and 1.35
If the average of the sensor impedance ratio is out of the standard value, the ECM interprets this
as a malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4742 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 25 of 43
CHART 19:
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Voltage Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.5 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.6 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Element Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$81Percentage of monitoring time
where Oxygen Sensor voltage is
less than 0.05 V
Multiply 0.3906%Between 0 and 95%
Time
$84Percentage of monitoring time
where Oxygen Sensor voltage is
0.70 V or more
Multiply 0.3906%Between 20 and
100%
Time
$85Maximum Rich (.0.45 V) timeMultiply 0.2621SecondBetween 20 and
66.8 seconds
If all the values (Time $81, Time $84 and Time $85) are out of the standard values, the ECM
interprets this as a malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4743 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 26 of 43
CHART 20:
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Voltage Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.5 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.6 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Element Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$81Percentage of monitoring time
where Oxygen Sensor voltage is
less than 0.05 V
Multiply 0.3906%Between 0 and 80%
Time
$84Percentage of monitoring time
where Oxygen Sensor voltage is
0.70 V or more
Multiply 0.3906%Between 20 and
100%
Time
$85Maximum Rich (.0.45 V) timeMultiply 0.2621SecondBetween 20 and
66.8 seconds
If all the values (Time $81, Time $84 and Time $85) are out of the standard values, the ECM
interprets this as a malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4744 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 27 of 43
CHART 21:
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Voltage Monitor
Related DTCs: P0130, P0150, P2195, P2196, P2197 and P2198
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.55 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Response Monitor
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$31Time to change from Lean
(30.4 V) to Rich (.0.55 V)N/ASecondBetween 0 and
0.8 seconds
Time
$32Time to change from Rich
(.0.55 V) to Lean (30.4 V)N/ASecondBetween 0 and
0.8 seconds
If the time required to change is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Frequency Monitor During
Engine Idling
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$33Average Lean (30.4 V) time of
one waveform cycleN/ASecondBetween 0 and
3.05 seconds
Time
$34Average Rich (.0.55 V) time of
one waveform cycleN/ASecondBetween 0 and
3.05 seconds
If the sum of Time $33 and Time $34 is out of the standard value, the ECM interprets this as a
malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4745 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 28 of 43
CHART 21 (Continued):
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Frequency Monitor During
Vehicle Running
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$35Average Lean (30.4 V) time of
one waveform cycleN/ASecond
Between 0 and
0.95 seconds
(varies depending
on feedback
compensation factor)
Time
$36Average Rich (30.55 V) time of
one waveform cycleN/ASecond
Between 0 and 0.95
seconds
(varies depending
on feedback
compensation factor)
If the sum of Time $35 and Time $36 is out of the standard value, the ECM interprets this as a
malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Voltage Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.5 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Element Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$81Percentage of monitoring time
where Oxygen Sensor voltage is
less than 0.05 V
Multiply 0.3906%Between 0 and 60%
Time
$84Percentage of monitoring time
where Oxygen Sensor voltage is
0.70 V or more
Multiply 0.3906%Between 20 and
100%
Time
$85Maximum Rich (.0.45 V) timeMultiply 0.2621SecondBetween 20 and
66.8 seconds
If all the values (Time $81, Time $84 and Time $85) are out of the standard values, the ECM
interprets this as a malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4746 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 29 of 43
CHART 22:
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Voltage Monitor
Related DTCs: P0130, P0150, P2195, P2196, P2197 and P2198
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.55 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Response Monitor
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$31Time to change from Lean
(30.4 V) to Rich (.0.55 V)N/ASecondBetween 0 and
0.9 seconds
Time
$32Time to change from Rich
(.0.55 V) to Lean (30.4 V)N/ASecondBetween 0 and
0.9 seconds
If the time required to change is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Voltage Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.5 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Element Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$81Percentage of monitoring time
where Oxygen Sensor voltage is
less than 0.5 V
Multiply 0.3906%Between 0 and 60%
Time
$84Percentage of monitoring time
where Oxygen Sensor voltage is
0.70 V or more
Multiply 0.3906%Between 20 and
100%
Time
$85Maximum Rich (.0.45 V) timeMultiply 0.2621SecondBetween 20 and
66.8 seconds
If all the values (Time $81, Time $84 and Time $85) are out of the standard values, the ECM
interprets this as a malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4747 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 30 of 43
CHART 23:
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Voltage Monitor
Related DTCs: P0130, P0150, P2195, P2196, P2197 and P2198
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.55 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Response Monitor
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$31Time to change from Lean
(30.4 V) to Rich (.0.55 V)N/ASecondBetween 0 and
0.9 seconds
Time
$32Time to change from Rich
(.0.55 V) to Lean (30.4 V)N/ASecondBetween 0 and
0.9 seconds
If the time required to change is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Frequency Monitor During
Engine Idling
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$33Average Lean (30.4 V) time of
one waveform cycleN/ASecondBetween 0 and
4.5 seconds
Time
$34Average Rich (30.55 V) time of
one waveform cycleN/ASecondBetween 0 and
4.5 seconds
If the sum of Time $33 and Time $34 is out of the standard value, the ECM interprets this as a
malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4748 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 31 of 43
CHART 23 (Continued):
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Frequency Monitor During
Vehicle Running
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$35Average Lean (30.4 V) time of
one waveform cycleN/ASecond
Between 0 and
0.9 seconds
(varies depending
on feedback
compensation factor)
Time
$36Average Rich (30.55 V) time of
one waveform cycleN/ASecond
Between 0 and
0.9 seconds
(varies depending
on feedback
compensation factor)
If the sum of Time $35 and Time $36 is out of the standard value, the ECM interprets this as a
malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Voltage Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.5 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Element Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$81Percentage of monitoring time
where Oxygen Sensor voltage is
less than 0.05 V
Multiply 0.3906%Between 0 and 60%
Time
$84Percentage of monitoring time
where Oxygen Sensor voltage is
0.70 V or more
Multiply 0.3906%Between 20 and
100%
Time
$85Maximum Rich (.0.45 V) timeMultiply 0.2621SecondBetween 20 and
66.8 seconds
If all the values (Time $81, Time $84 and Time $85) are out of the standard values, the ECM
interprets this as a malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4749 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 32 of 43
CHART 24:
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Voltage Monitor
Related DTCs: P0130, P0150, P2195, P2196, P2197 and P2198
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.55 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Response Monitor
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$31Time to change from Lean
(30.4 V) to Rich (.0.55 V)N/ASecondBetween 0 and
0.9 seconds
Time
$32Time to change from Rich
(.0.55 V) to Lean (30.4 V)N/ASecondBetween 0 and
0.9 seconds
If the time required to change is out of the standard value, the ECM interprets this as a malfunction.
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Frequency Monitor During
Engine Idling
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$33Average Lean (30.4 V) time of
one waveform cycleN/ASecondBetween 0 and
2.8 seconds
Time
$34Average Rich (.0.55 V) time of
one waveform cycleN/ASecondBetween 0 and
2.8 seconds
If the sum of Time $33 and Time $34 is out of the standard value, the ECM interprets this as a
malfunction. O2S
Failure
Threshold
Charts
(Continued)
Page 4750 of 4770

O2S TEST RESULTS (MODE 05) ± SS002-03December 17, 2003
Page 33 of 43
CHART 24 (Continued):
Front O2S (Bank 1 Sensor 1 and Bank 2 Sensor 1) Frequency Monitor During
Vehicle Running
Related DTCs: P0133 and P0153
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$35Average Lean (30.4 V) time of
one waveform cycleN/ASecond
Between 0 and 0.75
seconds
(varies depending
on feedback
compensation factor)
Time
$36Average Rich (30.55 V) time of
one waveform cycleN/ASecond
Between 0 and 0.75
seconds
(varies depending
on feedback
compensation factor)
If the sum of Time $35 and Time $36 is out of the standard value, the ECM interprets this as a
malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Voltage Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$07The minimum voltage during
O2S monitoringN/AVBetween 0 and 0.4 V
Time
$08The maximum voltage during
O2S monitoringN/AVBetween 0.5 and
1.275 V
If the sensor voltage is out of the standard value, the ECM interprets this as a malfunction.
Rear O2S (Bank 1 Sensor 2 and Bank 2 Sensor 2) Element Monitor
Related DTCs: P0136 and P0156
TEST IDDESCRIPTION OF TEST DATACONVERSION
FACTORUNITSTANDARD VALUE
OF TEST LIMIT
Time
$81Percentage of monitoring time
where Oxygen Sensor voltage is
less than 0.05 V
Multiply 0.3906%Between 0 and 90%
Time
$84Percentage of monitoring time
where Oxygen Sensor voltage is
0.70 V or more
Multiply 0.3906%Between 20 and
100%
Time
$85Maximum Rich (.0.45 V) timeMultiply 0.2621SecondBetween 20 and
66.8 seconds
If all the values (Time $81, Time $84 and Time $85) are out of the standard values, the ECM
interprets this as a malfunction. O2S
Failure
Threshold
Charts
(Continued)