19-13

Coolant pump, removing and installing


Note:
Coolant pump is bolted to bracket for generator,
power steering pump and viscous fan.

Lock carrier in service position Page 13
-1

Removing

CAUTION!

Before disconnecting the battery:

Stop the engine.
Determine the correct coding for the anti-
theft radio.
Switch the ignition off (also applies when
connecting the battery). Failure to do so may
damage the Engine Control Module (ECM).

- Switch ignition off and disconnect battery Ground (GND) strap.
- Remove ribbed belt Page 13
-15
.
- Remove viscous fan (with belt pulley) Page 13
-14
, Fig. 1
.
- Remove V-belt Page 13
-18
.
Pa
ge 14 of 34 Coolin
g system com
ponents, removin
g and installin
g
11/18/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE02.19.1

Page 19 of 34

19-17

Note:
When installing ribbed belt, check for correct
seating on belt pulley.

- Install V-belt Page 13
-18
.

- Fill up with coolant Page 19
-6 .

WARNING!

The cooling system is pressurized when the
engine is warm. When opening the expansion
tank, wear gloves and other appropriate
protection, cover the cap using a cloth, and
open carefully to relieve system pressure
slowly.

CAUTION!

Be sure the ignition is switched OFF. Failure
to do so may damage the Engine Control
Module (ECM).

- Switch ignition off and reconnect battery Ground
(GND) strap.

- After connecting battery, enter anti-theft code for
radio.

Pa
ge 19 of 34 Coolin
g system com
ponents, removin
g and installin
g
11/18/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE02.19.1