lock AUDI A4 1996 B5 / 1.G Instrument Cluster OBD From Model Year 2000 User Guide

Page 43 of 99

01-114

Read Measuring Value Block (scan tool
function 08)


Initiating "Read Measuring Value Block"
Rapid data transfer
HELP
Select function XX

Indicated on display
- Press buttons -0- and -8-. This selects "Read measuring value block",
function 08.
- Press -Q- button to confirm input.
Rapid data transfer
Q
08 - Measured value block

Indicated on display
- Press -Q- button to confirm input.
Read measured value block Input displa
y group number XXX

Indicated on display:
The selected measuring value block is now displayed in standard form. - Enter display group number (from table Page 01
-115
) and press -Q-
button to confirm input.
Pa
ge 43 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 50 of 99

01-118

Notes:

For an instrument cluster replacement, data
from display groups 10...15 must be printed out.
Measuring value blocks 125 and 126 indicate
the participants in the powertrain data-BUS.
Measuring value block 130 indicates the
participants in the comfort system databus.
Measuring value block 140 indicates the
participants in the information data-BUS
Display will always indicate the actual values
obtained from the sensors. The values which
appear on the instrument cluster are filtered
and may be different.
If the actual engine coolant temperature is
between 80 C and 100 C, instrument cluster
will always show 90 C.
Pa
ge 50 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 51 of 99

01-119
Measuring value block 001

Read Measuring Value Block 1

Indicated on display:

30 MPH 2400 RPM Oil p2 <min. 12: 20 h


Time



Oil pressure switch 2
Oil p2 < min. Oil p2 OK

Engine speed (RPM)

0 - 9990 RPM


Speed
0 - 187 MPH

Pa
ge 51 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 52 of 99

01-120
Measuring value block 2

Read Measuring Value Block 2

Indicated on display:

6256 mi 43 l 82 Ohm
23.0 C



Outside air temperature
-40 to +70 C




Tank sensor
approx. 280 Ohm (empty) ... approx. 40 Ohm (full)

Fuel gauge

0 - 100 1


Display value of trip odometer

Pa
ge 52 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 53 of 99

01-121
Measuring value block 3

Read Measuring Value Block 3

Indicated on display:


85.0 C











Coolant temperature

50 - 130 C


Pa
ge 53 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 54 of 99

01-122
Measuring value block 10

Read Measuring Value Block 10

Indicated on display:

Channel 30 128 Channel 9 626 mi


Input value for adaptation of odometer



Adaptation channel for odometer

Factory adjusted adaptation value

Adaptation channel of fuel gauge sender resistance range

Note:
If the value "128" in display field 2 was changed due to a customer complaint, the changed value must be transferred when
replacing instrument cluster.
Pa
ge 54 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 55 of 99

01-123
Measuring value block 11

Read Measuring Value Block 11

Indicated on display:

Channel 4 2 Channel 3 100


Factory adjusted adaptation value



Adaptation channel of fuel gauge

Selected language

1 is German
2 is English


Adaptation channel for language version of driver information display

Note:
If the value "100" in display field 4 was changed due to a customer complaint, the changed value must be transferred when
replacing instrument cluster.
Pa
ge 55 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 56 of 99

01-124
Measuring value block 12

Read Measuring Value Block 12

Indicated on display:

Channel 40 8 Channel 41 10


Time expired
For example, 10 means 10 days



Adaptation channel for time since service

Driven miles

8 means 800 miles


Adaptation channel for distance driven since service

Pa
ge 56 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 57 of 99

01-125
Measuring value block 13

Read Measuring Value Block 13

Indicated on display:

Channel 42 8 Channel 43 8


Maximum mileage
8 means 8000 miles
1)



Adaptation channel for maximum mileage


Minimum mileage performance
2)

8 means 8000 miles
1)


Adaptation channel for minimum mileage

Note:
1) The currently valid specifications can be found in the "Maintenance" book.
Repair Manual, Maintenance

2) For USA-vehicles: For instrument cluster of the manufacturer Marelli, the starting value (first value of remaining distance
without calculating) is set to 8000 miles. For instrument clusters of the manufacturer VDO, the starting value is set to 8100
miles. The 100 miles which are displayed in excess, are compensated during driving. For vehicles with 1.8 Liter Turbo engine,
the starting value of 5000 is set. For both manufacturers 8000 or 8100 miles is displayed anyway. The damper action also
occurs from the actual remaining interval during driving operation.
Pa
ge 57 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page 58 of 99

01-126
Measuring value block 14

Read Measuring Value Block 14

Indicated on display:

Channel 44 365








Maximum time interval
365 means 365 days/1 year
1)


Adaptation channel for maximum time interval

Note:
1) The currently valid specifications can be found in the "Maintenance" book.
Repair Manual, Maintenance

Pa
ge 58 of 99 Instrument cluster with lon
g service life, On Board Dia
gnostic
(OBD
) (from m.
y. 2000
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.EE01.01.2

Page:   < prev 1-10 11-20 21-30 next >