sensor AUDI A4 1997 B5 / 1.G AC System Electrical Testing Workshop Manual
Page 7 of 47
01-119
 Electrical testing, 1996
 
Note:  
Electrical testing, 1997     page 01
-135
 . 
Test 
number  Component(s) tested:  
Page  
1  
- A/C control head -E87- voltage supply, ground connection and illumination. Page 01
-
120
   
2  
- Temperature sensors G17, G56 and G89 Page 01
-
122
   
3  
- Fresh Air Blower V2 and Control module for fresh air blower J126 Page 01
-
124
   
4  
- Air/temperature distribution flap motors and related potentiometers V68/-G92-, -V70-/G112, 
V71/G113 and V85/G114)  Page 01
-
126
   
5  
- A/C compressor speed sender G111
- Refrigerant pressure switches -F118- and -F73-
- Interior Temperature Sensor Fan V42
- "A/C compressor intervention" output
- "Excessive engine temperature" signal Page 01
-
128
   
6  
- A/C Clutch Relay J44
- Actuation for coolant fan stage 1 Page 01
-
133
   
Pa
ge 7 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 10 of 47
01-122
 Test No. 2 (temperature sensors G17, G56 and G89)  VAG1598/11 adapter cable Measuring range: Resistance measurement (20 kohm)  
Test 
step  VAG1598 
socket  Test of  
Test conditions  
- additional steps  Specified values  
Corrective action  
2.1   48 + 52   Outside Air 
Temperature 
Sensor G17  
Measure 
temperature at 
mounting location 
of sensor -  resistance table, page 01
-
123
 (Resistance values 
depend on measured 
temperatures at mounting 
location of sensor(s) 
- Determine and rectify 
short circuit, open circuit 
in wiring or contact 
resistance using wiring 
diagram. 
- Replace applicable 
temperature sensor   
page 87
-106
 
2.2   50 + 52   Instrument Panel 
Interior 
Temperature 
Sensor G56  
Measure 
temperature at 
mounting location 
of sensor      
2.3   47 + 52   Fresh Air Intake 
Duct Temperature 
Sensor G89  Measure 
temperature at 
mounting location 
of sensor      
Pa
ge 10 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 11 of 47
01-123
 Temperature sensor resistances (based on ambient temperature, resistance in k ohm)  Temperature measured at mounting 
location of sensor  Instrument Panel 
Interior 
Temperature 
Sensor 
-G56-  Outside Air Temperature Sensor -G17- and Fresh Air 
Intake Duct Temperature Sensor -G89-  
-40 C (-40 F)  
(100)   (34.7)  
-30 C (-22 F)  (52.7)   18.1  
-20 C (1 F)  (28.6)   9.95  
-10 C (14 F)  16.2   5.59  
0 C (32 F)  9.40   3.28  
5 C (41 F)  7.27   2.54  
10 C (50 F)  5.66   1.99  
15 C (59 F)  4.45   1.57  
20 C (68 F)  3.50   1.25  
25 C (77 F)  2.79   1.00  
30 C (86 F)  2.23   0.80  
35 C (95 F)  1.80   0.65  
40 C (104 F)  1.45   0.53  
50 C (122 F)  0.79   0.36  
60 C (140 F)  0.67   0.25  
Pa
ge 11 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 18 of 47
01-128
 Test No. 5 (A/C Compressor Speed Sensor -G111-, refrigerant pressure switches -F118-, -F73- and Interior 
Temperature Sensor Fan -V42-)  
Note: 
Electrical test steps 5.1 to 5.4 do not apply to vehicles equipped with Nippondenso compressors (A/C compressor speed 
sensor G111 is not installed on Nippondenso compressors). VAG1598/11 adapter cable Measuring range: Resistance measurement (20 kilo ohm)  
Test 
step  VAG1598 
socket  Test of  
Test 
conditions  
- additional 
steps  Specified 
values  Corrective action  
5.1   5 + 49   A/C Compressor 
Speed Sender -G111-    
- 0.8 kW to 
1.5 kW - Determine and rectify open circuit in 
wiring, contact resistance or short circuit 
using wiring diagram. 
- Replace -G111-   page 87
-63
 .
5.2   5 and 
ground  A/C Compressor 
Speed Sender -G111-    
- greater 
than  
2 kW - Determine and rectify short circuit using 
wiring diagram. 
- Replace -G111-   page 87
-63
 .
Pa
ge 18 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 21 of 47
01-131
 
VAG1598/11 adapter cable Measuring range: Voltage measurement (20 V)  
Test 
step  VAG1598 
socket  Test of  
Test 
conditions  
- additional 
steps  Specified 
values  Corrective action  
5.6   3 + ground   A/C Refrigerant Low 
Pressure Switch -F73-  
Ignition on- approx. 
battery voltage - Determine and rectify open circuit in 
voltage supply using wiring diagram. 
- -F73- malfunction   page 87
-66
- Refrigerant circuit empty, refrigerant 
system pressure test   page 87
-190
 
VAG1598/11 adapter cable Measuring range: Amperage (20 amps (A))  
Test 
step  VAG1598 
socket  Test of  
Test 
conditions  
- additional 
steps  Specified 
values  Corrective action  
5.7   44 + 
ground  Interior 
Temperature 
Sensor Fan -V42-  
Ignition 
on - less than 
1 A 
- Blower 
V42 runs - Determine and rectify open circuit, short circuit to 
positive/ground in the wiring/connections between 
V42 and -E87- using wiring diagram. 
Pa
ge 21 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 25 of 47
01-135
 Electrical testing, 1997 
 
Note:  
Electrical testing, 1996   page 01
-119
 . 
Notes:  
 
VAG1598 test box must not be connected to A/C control head -E87- when performing On Board Diagnostic with VAG1551 
Scan Tool (ST) 
 Further notes, test requirements, connecting adapter cables and test equipment   page 01
-115
 .
 From m.y. 1997, do not connect VAG1598 test box to -E87- for test steps 1.1 through 5.7. (Test box only to be connected 
for test steps 5.8, 5.9 and 5.10). Test 
number  Component(s) tested:  
Page  
1  
- A/C control head -E87-, voltage supply and ground connection 
- Signal for time span ignition off Page 01
-
136
   
2  
- Temperature sensors -G17-, G56, -G89- -G191- and -G192-  Page 01
-
138
   
3  
- Fresh air blower -V2-, Control module for fresh air blower -J126-  Page 01
-
140
   
4  
- Air/temperature distribution flap motors and related potentiometers (-V68-/-G92-, -V70-/-
G112-, -V71-/-G113-, -V85-/-G114-)  Page 01
-
141
   
Pa
ge 25 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 26 of 47
5  
- A/C pressure switch -F129-
- "A/C compressor intervention" output 
- "Excessive engine temperature" signal
- Interior temperature sensor fan -V42- Page 01
-
142
   
6  
- A/C clutch relay -J44-, A/C clutch -N25-, actuation
- Coolant fan -V7-, actuation Page 01
-
146
   
Pa
ge 26 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 29 of 47
01-138
 Test No. 2 (Temperature Sensors -G17-, -G56-, -G89-, G191-, G192-. )  Adapter cable VAG1598/11  
Measuring range: Resistance measurement (20 K  / 200 K )  Test 
Step  VAG1598 
socket  Test of  
Test conditions  
- additional work  Specified Value  
Corrective action  
2.1 to 
2.3   page 01
-122
   
2.4   26 + 49   Sender for outlet 
temperature, 
center -G191-.  - Measure 
temperature at 
mounting location 
of sensor. - Dependant on temperature 
at mounting location of 
sensor - Diagnose and repair short, 
open circuit or contact 
resistance in 
wiring/connections using 
wiring diagram. 
2.5   25 + 49   Sender for outlet 
temperature, floor 
outlet -G192-.  - Measure 
temperature at 
mounting location 
of sensor.    Confirm using 
temperature/resistance 
table  page 01
-139
   
- Replace sensor(s)
Pa
ge 29 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 30 of 47
01-139
 Temperature sensor resistances (based on ambient temperature, resistance in k ohm)  
Temperature measured at mounting 
location of sensor   Sender for outlet temperature, 
center -G191-  Sender for outlet temperature, floor 
outlet -G192-  
-30 C (-22 F)  
(141)   (52,7)  
-20 C (1 F)  (85)   (28,6)  
-10 C (14 F)  (47)   16,2  
0C (32F)  (29)   9,40  
5C (41F)  (23,2)   7,27  
10 C (50 F)  18,6   5.66  
15 C (59 F)  15   4,45  
20 C (68 F)  12,2   3,50  
25 C (77 F)  10   2,79  
30 C (86 F)  8,2   2,23  
35 C (95 F)  6,8   1,80  
40 C (104 F)  5,7   1,45  
50 C (122 F)  4,0   0,97  
60 C (140 F)  2,9   0,67  
70 C (158 F)  2,1   0,47  
Pa
ge 30 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2 
Page 34 of 47
01-142
 Test No. 5 (A/C pressure switch -F129-, "A/C compressor intervention" signal, engine temperature signal from 
instrument cluster and Interior Temperature Sensor Fan -V42-)  Adapter cable VAG1598/11  
Measuring range: Resistance measurement (200  )  
Test 
Step  VAG1598 socket  
Test of  
Test conditions  
- additional work  Specified Value  
Corrective action  
5.1 to 
5.6  Not for 1997. A/C compressor speed sender -G111-, A/C high pressure switch -F118- and Low pressure switch -
F73- are no longer installed  
Adapter cable VAG1598/11  
Measuring range: Current measurement (20 A)  
Test Step  
VAG1598 socket  
Test of  
Test conditions  
- additional work  Specified Value  
Corrective action  
5.7    page 01
-131
   
Pa
ge 34 of 47 A/C s
ystem, electrical testin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.HA01.01.2