catalytic converter AUDI A4 1998 B5 / 1.G APB Engine Ignition System Checking

Page 13 of 64

28-11

Power output stages for ignition coils,
checking


Note:

Power Output Stage -N122 (black connector)
activates the ignition coils for cylinder bank 1
(cylinders 1 to 3).
Power Output Stage 2 -N192 (brown connector)
activates the ignition coils for cylinder bank 2
(cylinders 4 to 6).

Checking activation of power output stages

- Disconnect harness connectors from all six fuel
injectors.

Note:
It is important to ensure that no fuel is injected
during the test as this would damage the catalytic
converter. The harness connectors on the fuel
injectors must therefore be disconnected.
Pa
ge 13 of 64 I
gnition s
ystem, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU04.28.1