AUDI A4 1998 B5 / 1.G Interior Monitor Owner's Guide
Page 31 of 44
Specification: 8 V
- End output Diagnostic Test Mode (DTM).
- Install ultra-sound sensors again
- Erase DTC memory (function 05) page 01
-137
.
- End output (function 06) page 01
-139
.
Pa
ge 31 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 32 of 44
01-130
Checking wiring for pulse signal
- Remove both ultra-sound sensors.
Repair Manual, Body Interior, Repair Group
70, B
-pillar trim , removing and installing
- Disconnect electronic harness connectors.
- Perform Output Diagnostic Test Mode (DTM) (
page 01
-124
) and select control element test
"Signal pulse wire."
Output Diagnostic Test Mode Signal pulse wire
Indicated on display
- Using multimeter (Fluke 83 or equivalent), measure voltage at wiring
harness connector between terminal 1 (pulse signal) and terminal 3
(GND).
Specification: 5 V
- End Output Diagnostic Test Mode (DTM).
- Re-install ultra-sound sensors.
- Erase DTC memory (function 05) page 01
-137
.
- End Output (function 06) page 01
-139
.
Pa
ge 32 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 33 of 44
01-131
Code Control Module (scan tool function
07)
This function can be used to code the interior
monitoring as follows:
Vehicle type: Audi A4
Arming mode of anti-theft system: dynamic
(m.y. 1997), or static (as of m.y. 1998)
Body version: Sedan/Avant
Notes:
The coding adjusts the control module for ultra-
sound sensors -J347- to meet the specific
requirements of the particular model version
and anti-theft alarm system.
The coding table gives only the coding
applicable to the Audi A4.
Carrying out "Code Control Module" function
07
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -7- to select "Code Control Module" function 07.
Pa
ge 33 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 34 of 44
Rapid data transfer
Q
07 - Code Control Module
Indicated on display
- Press -Q- button to confirm input.
Pa
ge 34 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 35 of 44
01-132
Code Control ModuleEnter code number XXXXX
(0-32000)
Indicated on display
- Enter code number:
Coding:
00101
00 Place holders, disregard
1 Audi A4
0 Arming mode static
1 Sedan
2 Avant
Code Control Module
Q
Enter code number 00101
(0-32000
)
- Indicated on display
- Press -Q- button to confirm input.
4B0951173 Interior monitoring
D02
Coding 00101
WSC 06812
Indicated on display
-
End coding by pressing button.
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -6- to select "End Output" function 06.
This will end the function.
Rapid data transfer
Q
06 - End Output
Indicated on display
- Press -Q- button to confirm input.
Pa
ge 35 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 36 of 44
01-133
Read Measuring Value Block (scan tool
function 08)
Carrying out "Read Measuring Value Block"
function 08
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -0- and -8- to select "Read Measuring Value Block"
function 08.
Rapid data transfer
Q
08 - Read Measurin
g Value Block
Indicated on display
- Press -Q- button to confirm input.
Read Measuring Value BlockInput displa
y group number XXX
Indicated on display
The selected measuring value block is now indicated in standard format.
Evaluation page 01
-134
. - Press buttons -0-, -0- and -1- to input display group number 1 (001).
- Press -Q- button to confirm input.
Pa
ge 36 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 37 of 44
01-134
Read Measuring Value Block, overview
Display group 001
Indicated on Display
Display value
Identification
Read Measuring Value Block 1 0100 1) 1 = switch positions
1 2 3 4
100% 1) 2 = sensitivity of the sensors
3 = not assigned
4 = not assigned 1) Example of display.
Display value table
1
2
Switch for Int. Monitoring:
Driver-side door contact switch
Anti-theft warning system:
Glass breakage system 2): : pressed = 1, not pressed = 0
: driver-side door open = 1, driver-side door closed = 0
: armed = 1, not armed = 0
: present = 1, not present = 0 50 ... 100% 3)
2) Avant only. 3) Refer to "Adaptation" function 10 page 01
-135
.
Pa
ge 37 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 38 of 44
01-135
Adaptation (scan tool function 10)
The following changes can be implemented and
saved using the adaptation function:
Sensitivity settings of the ultra-sound sensors
can be set so that the sensors react with less
sensitivity.
Carrying out "Adaptation" function 10
Rapid data transfer
HELP
Select function XX
Indicated on display
- Press buttons -1- and -0- to select "Adaptation" function 10.
Rapid data transfer
Q
10 - Adaptation
Indicated on display
- Press -Q- button to confirm input.
AdaptationInsert channel number XX
Indicated on display
- Press buttons -0- and -1- to insert channel number 1.
Adaptation
Q
Channel displa
y 1
Indicated on display
- Press -Q- button to confirm input.
Pa
ge 38 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 39 of 44
01-136
Channel 1 Adaptation 100 Sensitivity in %
- 1 3-
Indicated on display (sensitivity of sensors is displayed: e.g. 100%)
Note:
The factory adjusted maximum sensitivity of the ultra-sound sensors is
designated as 100%. The sensor sensitivity can be reduced to 50 %.
-
Press button.
Channel 1 Adaptation 100 Input adaptation value XXXXX
Indicated on display
- Enter sensitivity value (e.g. 75% = 00075).
Channel 1 Adaptation 100
Q
Input adaptation value 00075
Indicated on display
- Press -Q- button to confirm input.
Channel 1 Adaptation 75
Q
Sensitivity in %
(-1 3-
Indicated on display
- Press -Q- button to confirm input.
Channel 1 Adaptation 75
Q
Store changed value?
Indicated on display
- Press -Q- button to confirm input.
Channel 1 Adaptation 75 Chan
ged value is stored
Indicated on display
-
Press button to end adaptation procedure for sensitivity.
Rapid data transfer
HELP
Indicated on display
Pa
ge 39 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4
Page 40 of 44
Insert address word XX
Pa
ge 40 of 44 Ultrasonic interior monitorin
g On Board Dia
gnostic
(OBD
)
11/20/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.BD04.01.4