24-64


Intake manifold change-over
valve, checking
Component locations page 24
-1 .

- Disconnect intake manifold change-over valve
harness connector.

If the specified value is not obtained: -
Switch multimeter (Fluke 83 or equivalent) to measure resistance ( )
and connect between terminals on valve.
Specified value: 25 to 35 ohms ( )- Replace intake manifold change-over valve.
Pa
ge 1 of 4 Intake manifold chan
ge-over valve, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.17

Page 2 of 4

24-65

Checking voltage supply

If voltage tester does not light up: - Disconnect intake manifold change-over valve harness connector.
- Connect VAG 1527B voltage tester between harness connector
terminal 1 and Ground (GND) using jumper wires from connector test
kit VW 1594.
- Use scan tool "Output Diagnostic Test Mode" function 03 to trigger fuel
pump relay -J17- page 01
-145
.
Voltage tester must light up
- Check fuse for intake manifold change-over valve.

- Check wiring for continuity between intake manifold change-over valve
harness connector terminal 1 and fuse, using wiring diagram.

Specified value: max. 1.0 - Check fuel pump relay and triggering page 24
-24
.
Pa
ge 2 of 4 Intake manifold chan
ge-over valve, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.17

Page 3 of 4

24-66

Checking triggering

If voltage tester does not flash, or lights up constantly:
If voltage tester lights constantly:
If voltage tester does not flash: - Connect VAG 1527B voltage tester between intake manifold change-
over valve connector terminal 1 (B+) and 2 using jumper wires from
connector test kit VW 1594.
- Use scan tool "Output Diagnostic Test Mode" function 03 to trigger
Intake manifold change-over valve page 01
-145
.
Voltage tester must flash
- Connect VAG 1598/19 test box to ECM page 01
-255
.
- Check wiring from intake manifold change-over valve connector
terminal 2 to test box socket B4 to Ground (GND).
- Check wiring for continuity between terminal 2 of intake manifold
change-over valve connector and socket B4 of test box.

Specified value: max. 1.0

If wiring is OK: - If necessary eliminate break in wiring or short to Ground.
Pa
ge 3 of 4 Intake manifold chan
ge-over valve, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.17

Page 4 of 4

- Replace ECM page 01
-265
.
Pa
ge 4 of 4 Intake manifold chan
ge-over valve, checkin
g
11/22/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU01.24.17