-  Remove intake air duct between cowl and air 
cleaner housing. 
     
-  Remove air cleaner housing cover.
    
-  Remove the following lines/harness connectors:
1 - At wastegate bypass regulator valve -N75-
2 - At Evaporative Emissions (EVAP) purge regulator valve -N80-
3 - At power output stage -N122-
4 - At Mass Air Flow (MAF) sensor -G70-
-  Remove hose connections and remove air cleaner housing (arrows).
-  Remove engine covers. 
    
-  Unbolt crankcase ventilation hose -1- at cylinder head cover and heat 
shield. 
-  Unbolt both oil supply line bolts -3-.
-  Remove heat shield -4-. 
-  Remove sleeve -2- from coolant return hose.
Pa
ge 41 of 50 Turbochar
ger s
ystem
11/18/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.GE02.21.1 
Page 45 of 50
21-33
      
Note:  
     Add oil to turbocharger through oil supply line 
connection flange. 
     
-  Fill up coolant   Page 19
-4 .
     
WARNING! 
     
The cooling system is pressurized when the 
engine is warm. When opening the expansion 
tank, wear gloves and other appropriate 
protection, cover the cap with a cloth and 
open carefully to relieve system pressure 
slowly. 
     
Note:  
     After installing the turbocharger, let engine idle 
for approx. 1 minute without increasing engine 
speed. This ensures adequate oil supply to the 
turbocharger. 
     
-  Check engine oil level   Page 17