lock AUDI A6 1998 C5 / 2.G ATQ Engine Electronic Engine Power Control Checking Workshop Manual

Page 22 of 41

24-149
Angle sensor 1 for throttle drive (power
accelerator actuation) -G187- and angle sensor 1
for throttle drive (power accelerator actuation) -
G188- inform the Engine Control Module (ECM)
about the position of the throttle valve. Both
angle sensors are located in the throttle valve
control module.

Test sequence

- Connect VAS5051 tester or VAG1551 scan tool
and select the control module for engine
electronics using "address word" 01 Page 01
-
9 .

Ignition must remain switched on for this.Rapid data transfer
HELP
Select function XX

When indicated on display:
- Press buttons -0- and -8- to select "Read Measuring Value Block" and
press -Q- button to confirm input.
Read Measuring Value Block
Q
Input displa
y group number XXX

When indicated on display:
- Press buttons -0-, -6- and -2- to select "display group number 062" and
press -Q- button to confirm input.
Read Measuring Value Block 62
1
2
3
4

Indicated on display:
- Check specified values for E-gas potentiometer voltages in display
fields 1 and 2.
Pa
ge 22 of 41 Electronic en
gine
power control
(E-Gas
), checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.5

Page 29 of 41

24-155
Both the Throttle Position (TP) sensor -G79- and
the Sender -2- for accelerator pedal position -
G185- are located at the accelerator pedal and
communicate the driver's intentions to the ECM
completely independently of each other. Both
sensors are stored in one housing.

Test sequence

- Connect VAS5051 tester or VAG1551 scan tool
and select the control module for engine
electronics using "address word" 01 Page 01
-
9 .

Ignition must remain switched on for this.Rapid data transfer
HELP
Select function XX

When indicated on display:
- Press buttons -0- and -8- to select "Read Measuring Value Block" and
press -Q- button to confirm input.
Read Measurin
g Value Block
Q
Input display group number XXX

When indicated on display:
- Press buttons -0-, -6- and -2- to select "display group number 062" and
press -Q- button to confirm input.
Read Measuring Value Block 62
1
2
3
4

Indicated on display:
- Check specified values for E-gas potentiometer voltages in display
fields 3 and 4.
Pa
ge 29 of 41 Electronic en
gine
power control
(E-Gas
), checkin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re