relay AUDI A6 1998 C5 / 2.G ATQ Engine Motronic Injection System Servicing User Guide
Page 65 of 78
24-55
      
-  Connect multimeter for voltage measurement to 
Ground (GND) and to one terminal of the 
following fuses in the fuse holder. 
     
Fuse  
Specified value at one of the 
terminals  
S228   approx. battery voltage  
S229   approx. battery voltage  
S234   approx. battery voltage  
      If specified values are not obtained:  
     
-  Repeat test at another terminal of fuse socket.
      If specified values are not obtained again:  
     
-  Check wire connections.
     
       Electrical Wiring Diagrams, Troubleshooting & 
Component Locations binder         If no malfunctions are detected:  
     
-  Replace Fuel Pump (FP) relay -J17-.
     
-  Re-insert the fuses.
Pa
ge 65 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1 
Page 73 of 78
24-61
      
Voltage supply for Mass Air Flow (MAF) 
sensor, checking  
     
-  Disconnect connector from Mass Air Flow (MAF) 
sensor. 
    
Note:  
Voltage is supplied to Mass Air Flow (MAF) sensor from Fuel Pump (FP) 
relay. 
If specified value is not obtained:  
 Electrical Wiring Diagrams, Troubleshooting & Component Locations 
binder    -  Connect multimeter for voltage measurement as follows.Harness connector  
Terminal  
Measure to  
3   Engine Ground (GND)  
-  Operate starter briefly. 
 
Specification: approx. battery voltage
-  Check wire connection from terminal 3 of connector to Fuel Pump (FP) 
relay via fuse for open circuit and short circuit to Ground (GND): 
Pa
ge 73 of 78 Motronic in
jection s
ystem, servicin
g
11/23/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU05.24.1