battery AUDI A6 2000 C5 / 2.G AEB Engine Throttle Valve Control Module And Checking
Page 31 of 38
24-117
Continuation (with measured voltage)
If measured voltage was approx. 5 volts:
If measured voltage was approx. battery positive voltage (B+): - Disconnect 8-pin harness connector from throttle valve control module
-J338-.
- Connect multimeter US 1119 (Fluke 83 or equivalent), using adapter
cables from VW 1594 connector test kit.
- Measure resistance to check for short circuit between test box sockets
62 (power supply) and 75 (signal wire).
Test box sockets 62 and 75
Specified value:
- Check wiring at 8-pin connector, terminal 5 for short circuit to battery
B+.
Pa
ge 31 of 38 Throttle valve control module, checkin
g
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.24.2