lock AUDI A8 1999 D2 / 1.G AEB Engine Readiness Codes
Page 2 of 22
Select function XX
-  Press buttons -0- and -8- to select "Read Measuring Value Block" 
function 08, and press -Q- button to confirm input. 
Pa
ge 2 of 22 Readiness code
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2 
Page 3 of 22
01-60
 
Read Measurin
g Value Block 
HELP
Input display group number XXX
    
Indicated on display  
-  Press buttons -0-, -8- and -6- to input display group number 86, and 
press -Q- button to confirm input. 
Read Measurin
g Value Block 86 
 
1 
2 
3 
4
    
Indicated on display (1-4   display fields)  
Note:  
The readiness code is generated as soon as only zeros ("0") are shown in 
display field 1. -  Check readiness code values in display field 1.
   Specified value: 00000000 
- 
Press  button to advance program sequence.
Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press buttons -0- and -6- to select "End Output" function 06, and press 
-Q- button to confirm input. 
Pa
ge 3 of 22 Readiness code
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2 
Page 8 of 22
01-65
      
Step 3: Adaptation of throttle valve control 
module to ECM Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Value Block" 
function 08, and press -Q- button to confirm input. 
Read Measuring Value Block 
HELP
Input displa
y group number XXX
    
Indicated on display  
-  Press buttons -0-, -6- and -0- to input display group number 60, and 
press -Q- button to confirm input. 
Read Measuring Value Block 60  
1 
2 
3 
4
    
Indicated on display (1-4   display fields)  -  Press -4- button to select "Basic Setting" function 04 (adaptation of 
throttle valve control module to ECM) 
System in Basic Setting 60  
1 
2 
3 
4
    
Indicated on display (1-4   display fields)  -  Check specified values in display fields 3 and 4:
Pa
ge 8 of 22 Readiness code
11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2 
Page 11 of 22
01-68
      
Step 5: Oxygen Sensor (O2S) control 
operating condition Rapid data transfer 
HELP
Select function XX
    
Indicated on display  
-  Press buttons -0- and -8- to select "Read Measuring Value Block" 
function 08, and press -Q- button to confirm input. 
Read Measuring Value Block 
HELP
Input displa
y group number XXX
    
Indicated on display  
-  Press buttons -0-, -3- and -0- to input display group number 30, and 
press -Q- button to confirm input. 
Read Measuring Value Block 30  
1 
2 
3 
4 
    
Indicated on display (1-4   display fields)  -  Increase engine speed to 1800-2200 RPM.
-  Hold at 1800-2200 RPM until:
 
Specified value of "111" is reached in display field 1
 Specified value of "110" is reached in display field 2
Pa
ge 11 of 22 Readiness code11/19/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU02.01.2