wiring AUDI TT 1995 8N / 1.G ATW Engine Oxygen Sensor Control Workshop Manual

Page 10 of 37

24-80
Evaluation display group 033 Display field:
2
Possible cause
Corrective action
constant about
0.450 V
Open circuit in wire 4 between oxygen sensor
and control module - Check primary voltage Page 24
-80


Open circuit in wire 3 between oxygen sensor
and control module
constant about
0.200 V Oxygen sensor faulty- Replace oxygen sensor
larger than
1.100 V Short circuit to B+ in wire 4 between oxygen
sensor and control module - Check oxygen sensor wiring, oxygen sensor
before catalytic converter Page 24
-81

smaller than
0.150 V
Short circuit to Ground (GND) in wire 4 between
oxygen sensor and control module

Checking primary voltage

Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant hoses
can remain connected. - Disconnect 4-pin harness connector -2- (black) to Heated Oxygen Sensor
(HO2S) -G39- before catalytic converter.
Pa
ge 10 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 11 of 37

24-81


If specified value is not obtained:
If specified value is obtained:
Checking oxygen sensor wires - Connect multimeter between terminal 3 and 4 for voltage
measurement.
- Switch ignition on.

Specification: 0.400 to 0.500 V
- Switch ignition off.
- Check oxygen sensor wiring.
- Replace Heated Oxygen Sensor (HO2S) -G39-.

Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 4-pin harness connector -2- (black) to Heated Oxygen
Sensor (HO2S) -G39- before catalytic converter.
Pa
ge 11 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 12 of 37

24-82

- Connect VAG1598/31 test box at wiring harness
to Engine Control Module (ECM), do not connect
ECM Page 24
-19
.

If wire connection is OK: - Check following wire connections for open circuit.Harness connector
Terminal
VAG1598/31 test box
Socket
3 51
4 70
- Repair open circuit if necessary.
- Check wires to each other for short circuit.
- Replace Engine Control Module (ECM) Page 24
-23
Pa
ge 12 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 24 of 37

24-94
Evaluation display group 037 Display field:
2
Possible cause
Corrective action
constant about
0.450 V
Open circuit in wire 4 between oxygen sensor
and control module - Check primary voltage Page 24
-96


Open circuit in wire 3 between oxygen sensor
and control module
larger than
1.100 V Short circuit to B+ in wire 4 between oxygen
sensor and control module - Check oxygen sensor wiring, oxygen sensor
behind catalytic converter Page 24
-97

smaller than
0.150 V
Short circuit to Ground (GND) in wire 4 between
oxygen sensor and control module
Pa
ge 24 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 26 of 37

24-96

Checking primary voltage

Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 4-pin harness connector -1- (brown) to Oxygen Sensor
(O2S) behind Three Way Catalytic Converter (TWC) -G130-.

If specified value is not obtained:
If specified value is obtained: - Connect multimeter between terminal 3 and 4 for voltage
measurement.
- Switch ignition on.

Specification: 0.400 to 0.500 V
- Switch ignition off.
- Check oxygen sensor wiring.
- Replace Oxygen Sensor (O2S) behind Three Way Catalytic Converter
(TWC) -G130-.
Pa
ge 26 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 27 of 37

24-97

Checking oxygen sensor wires

Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 4-pin harness connector -1- (brown) to Oxygen Sensor
(O2S) behind Three Way Catalytic Converter (TWC) -G130-.
- Connect VAG1598/31 test box at wiring harness to Engine Control
Module (ECM), do not connect ECM Page 24
-19
.

- Check following wire connections for open circuit.Harness connector
Terminal
VAG1598/31 test box
Socket
3 68
4 69
Pa
ge 27 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 30 of 37

24-100

Test requirements:

Coolant Temperature at least 80 C.

Fuse for oxygen sensor heating OK

Electrical Wiring Diagrams, Troubleshooting &
Component Locations

Test sequence

or
Note:
Coolant reservoir screws must be removed and coolant reservoir must be
placed to side in order to access the harness connector. The coolant
hoses can remain connected. - Disconnect 4-pin harness connector -2- (black) to Heated Oxygen
Sensor (HO2S) -G39- before catalytic converter.
- Disconnect 4-pin harness connector -1- (brown) to Oxygen Sensor
(O2S) behind Three Way Catalytic Converter (TWC) -G130-.
Pa
ge 30 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2

Page 34 of 37

24-103
If there is no voltage again:

- Check wire connection from terminal 1 of
connector to Fuel Pump (FP) relay via fuse for
open circuit:

Electrical Wiring Diagrams, Troubleshooting &
Component Locations If voltage supply is OK:

If there is no voltage: - Connect multimeter for voltage measurement as follows:Harness connector
Terminal
Measure
to
2 (Ground -GND- activation of Engine Control Module -
ECM-) B+
- Start engine.

Specification: approx. battery voltage, possibly fluctuating
- Switch ignition off.
- Connect VAG1598/31 test box at wiring harness to Engine Control
Module (ECM), do not connect ECM Page 24
-19
.
Pa
ge 34 of 37 Ox
yg
en sensor control, checkin
g
11/21/2002 htt
p://127.0.0.1:8080/audi/servlet/Dis
play?action=Goto&t
yp
e=re
pair&id=AUDI.B5.FU06.24.2