pressure Citroen C2 2004 1.G Manual Online

Page 507 of 523

Downloaded from www.Manualslib.com manuals search engine 503
AIRCON
AIR CONDITIONING SYSTEM R 134.a
(1)High pressure valve.
(2) Low pressure valve.
(3) Filter.
(4)Pressostat.
Tightening torques (m.daN).
(a) : 0,6
(b) : 0,6
(c) : 0,6
(d) : 0,6
(e):0,6
(f) : 0,6
C5HP17SP
C3 C3 PLURIEL

Page 508 of 523

Downloaded from www.Manualslib.com manuals search engine 504
AIRCONAIRCON
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP1A5D
Key.
T/P
= Average temperature (°C)at the air vents/
high pressure (Bars).
P= Low pressure (Bars).
Te= Exterior temperature (C°).
HP= Pressure at compressor outlet (Bars).
BP= Pressure at compressor inlet (Bars).
TA = Average temperature (°C)of air blown from the
central vents.
C3 C3 PLURIEL BVA KFV

Page 509 of 523

Downloaded from www.Manualslib.com manuals search engine 505
AIRCON
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP18GD
Key.
T/P
= Average temperature(°C ) at the air vents/
high pressure(Bars).
P = Low pressure(Bars).
TE = Exterior temperature(C°).
HP = Pressure at compressor outlet(Bars).
BP = Pressure at compressor inlet(Bars).
TA = Average temperature(°C) of air blown from
the central vents.
C3 C3 PLURIEL NFV

Page 510 of 523

Downloaded from www.Manualslib.com manuals search engine 506
ELECTRICAL
SYSTEM
AIR CONDITIONING SYSTEM R 134.a
Checks on the air conditioning circuit
C5HP1A8D
Key.
T/P
= Average temperature(°C ) at the air vents/
high pressure(Bars).
P
= Low pressure(Bars).
TE = Exterior temperature(C°).
HP = Pressure at compressor outlet (Bars).
BP = Pressure at compressor inlet(Bars).
TA = Average temperature(°C) of air blown from
the central vents.
C3 C3 PLURIEL BV MECANIQUE 8HX 8HW

Page 511 of 523

Downloaded from www.Manualslib.com manuals search engine 507
ELECTRICAL
SYSTEM
Plan of air conditioning system.
Two solutions:
1/ «MANULLI»
, with «NON EUROCLIM» compressor (Oring seals).
2/
«EATON», with «EUROCLIM»compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a): 0,8
(b):4 ± 0,4
(c) : 0,8
A
Right hand drive.
XSARA KFW NFU TU TT AIR CONDITIONING SYSTEM R 134.a
C5HP16RP

Page 512 of 523

Downloaded from www.Manualslib.com manuals search engine 508
Plan of air conditioning system.
Solution:
1/ «EATON»
, with «EUROCLIM»compressor and buffer capacity (quadrilobe
seals)
.
(1)High pressure valve.
(2)Low pressure valve.
(3)Buffer capacity.
Tightening torques (m.daN).
(a):0,8
(b):4 ±0,4
(c) : 0,8
A
Right hand drive.
XSARA RFNAIR CONDITIONING SYSTEM R 134.a
C5HP17WP
AIRCONAIRCON

Page 513 of 523

Downloaded from www.Manualslib.com manuals search engine 509
AIRCON
Plan of air conditioning system.
Two solutions :
1/ «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2/ «EATON», with «EUROCLIM»compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a):0,8
(b) : 4 ± 0,4(c): 0,8
A
Right hand drive.
XSARA RFN
AIR CONDITIONING SYSTEM R 134.aw
C5HP16SP

Page 514 of 523

Downloaded from www.Manualslib.com manuals search engine 510
Plan of air conditioning system.
Two solutions:
1/ «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2/ «EATON», with «EUROCLIM»compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA RFSAIR CONDITIONING SYSTEM R 134.a
C5HP16VP
AIRCONAIRCON

Page 515 of 523

Downloaded from www.Manualslib.com manuals search engine 511
AIRCON
Plan of air conditioning system.
Three solutions:1) «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2)«EATON», with «EUROCLIM»compressor and buffer capacity (quadrilobe seals).
3) «EATON», with «NON EUROCLIM»compressor and buffer capacity (Oring seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Buffer capacity.
Tightening torques (m.daN).
(a) : 0,8
(b): 4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA WJY RHY
AIR CONDITIONING SYSTEM R 134.a
C5HP17XP

Page 516 of 523

Downloaded from www.Manualslib.com manuals search engine 512
Plan of air conditioning system.
Two solutions:
1/ «MANULLI»
, with «NON EUROCLIM»compressor (Oring seals).
2/ «EATON», with «EUROCLIM»compressor (quadrilobe seals).
(1)High pressure valve.
(2)Low pressure valve.
(3)Pressostat.
(4)Dryer.
Tightening torques (m.daN).
(a) : 0,8
(b):4 ± 0,4
(c):0,8
A
Right hand drive.
XSARA WJY RHYAIR CONDITIONING SYSTEM R 134.a
C5HP16TP
AIRCONAIRCON

Page:   < prev 1-10 ... 41-50 51-60 61-70 71-80 81-90 91-100 next >