door lock DACIA SUPERNOVA 2004 Owner's Manual

Page 495 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 28
8. 14G STATE : BLOCKING/ UNLOCKING DOORS
RECOMMENDATION The state 10G (anti starting) must be ACTIVE.
Check the continuity and the isolation related to the +12 V and to the ground of the electric
wiring on the line
E.C.U. decoder Pin B2 pole 1 door locking switch. Pin B5 pole 3
Fix the electric wiring if necessary or replace the switch.
If the incident persists, replace the E.C.U. decoder.
Remove the memorised failure by means of the CLIP tester.
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su

Page 499 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 32
ALP3. THE ANTI STARTING INDICATOR REMAINS PERMANENTLY LIGHTED
(even when the contact is taken off) OR IT REMAINS PERMANENTLY SWITCHE D OFF.
RECOMMENDATIONCheck if the “Procedure E.C.U. decoder replacement” was correctly
performed.
Check the fuse F15 ( up to 01.06.2001) or
F07 (after 01.06.2001).
Is the fuse good?
Is there the failure “ DOORS’ LOCKING
CONTACT”?
Check the continuity and the isolation related
to the ground, between t he pin A 5 of the
E.C.U. decoder and the dashboard.
Is the wiring good?
Replace the fuse.
Analyse this failure and replace.
Fix the wiring.
Perform the following tests in order to find the
failure element:
- if the anti starting indicator is permanently
lighted, disconnect the connector of the E.C.U.
decoder and check if the indicator switches off;
- if the anti starting system is turned off,
c onnect the pin A5 of the wiring connector from
the E.C.U. decoder to an electric ground and
check if the indicator turns on.
Are the answers affirmatives?
Replace the instrument panel.
Replace the E .C.U. decoder.
Perform a conformity checking.
AFTER REPAIRING Check the operation of the anti starting system. Remove by means of the CLIP tester the possibl e memorised failures.
No
No
No
Yes
Yes
No
Yes
YesDIAGNOSTIC
vnx.su

Page 502 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 35
A
LP6. BLOCKING/UNLOCKING DOORS NOT OPERATING
RECOMMENDATION Check with the CLIP tester the absence of the failures.
If there are memorised failures, these must be removed.
Are the doors blocking mechanisms correctly
operating ?Repair the damaged mechanisms.No
Check the continuity a nd the isolation related to the ground
of the wiring between :
E.C.U . d ecoder pin B8 actuators
Pin B9 doors
Is the wiring in good condition?
Fix the wiring.No
Check the continuity a nd the isolation related
to the ground of the wiring between
E.C.U .pin B8 switch
d ecoder pin B9 blocking doors
Is the wiring in good condition?
Repair.
Di sconnect the E.C.U. decoder, then supply
the wiring connector with +12 V at pin B9 and
the ground at the pin B8, than versa (+ 12 V at
pin B8 and the ground at pin B9).
Ar e the actuators bl ocking/unlocking the
doors?
Damaged actuators.
Replace them.
Replace the E.C.U. decoder, then perform the “E.C.U. decoder replacement
procedure”. No
Yes
Yes
No
YesYes
AFTER REPAIRING Perform a conformity
checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su

Page 503 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 36
A
LP7. UNLOCKING DOORS NOT OPERATING BY RF REMOTE CONTROL
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, these must be repaired.
Are the states 11G and 11D ACTIVE when
the RF remote control is activated?S ee the treatment states 11G and
1 1D cf. Chapter “Diagnostic”.No
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?
Replace the fuse.No
Yes
Yes
Activate the doors’ locking switch from t he
dashboard.
Are the doors blocking/ unlocking ? S
ee the treatment of the failure
“Doors blocking contact” and the
state 14 G cf. Chapter “Diagnostic”.
S ee ALP 6.
Yes
No
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
DIAGNOSTIC
vnx.su

Page 504 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 37
A
LP8. TURNING LIGHTS DO NOT SWITCH ON AT THE BLOCKING /
UNLOCKING OF THE DOORS
RECOMMENDATION Check the absence of the failures with the CLIP tester.
If there are failures, fix them first.
Check if the synchronisatio n of the RF remote control and the E.C.U. decoder has been performed .
Are the turning lights functioning normally at the activation of the signalling switch ?
Check the continuity and the isolation related to
the ground and the +12 V of the electric layout:
E.C.U. decoder FLASH relay
Pin B3 pole 2
Is it correct?
Repair the signalli ng system.
Check t he fuse F03 and F04.
Fix the electric layout.
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?Replace the fuse.
Disconnect the FLASH relay. Supply with
+ 12, the pole 4 of the relay. Are the l eft
turning lights turning on? Supply with +12 V
the pole 5 of the signal relay.
Are the right turning lights turning on?
Repair the electric layout from
poles 4 and 5 of the FLASH relay.
Replace the FLASH relay.
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
No
No
No
Yes
Yes
Yes
Yes No
DIAGNOSTIC
vnx.su

Page 505 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 38
No
AFTER REPAIRING Perform a conformity
checking.
Check the operation of the anti starting system.
A LP9. THE CEILING LAMP DOES NOT SWITCH ON AT THE BLO CKING /
UNLOCKING OF THE DOORS OR IT REMAINS PERMANENTLY TURNED ON.
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, fix them first.
Check if t he doors are locked?
Has the ceiling lamp turned on? The ceiling lamp was in the
position “p
ermanently
lighting”. Normal
operation.Yes Yes
Unlock the doors with the RF remote control.
The ceiling is in the position “dome lighting”
Has the ceiling lamp turned on?
Check the isolation of the wiring
related to the ground on the line pinA1.
decoder ceiling
After 15 seconds, the ceiling lamp will
turn off.
Normal operation.
Was the E.C.U. decoder confi gured “With
dome ceiling ”?Configure the E.C.U. decoder with
the CLIP tester.
Check the continuity on the line
E. C.U. decoder pin A1 ceiling
Is the line good?Repair .
Check the ceiling lamp bulb.
No
No
No
Yes
Yes Yes
No
DIAGNOSTIC
vnx.su

Page 507 of 933

82A
HORN - ENGINE IMMOBILISER
82A - 40
11. Remote control signal reception 11G = activate the RF ACTIVE for 3 secondsremote control decoder receives the
Received signal indication the remote control signal
12. Remote control signal validation 11D = activate the RF ACTIVE for three sec. remote control if the signal received at
Good signal indication the decoder is good
13. Communication doors locking 14G = blocking/ unlocking ACTIVE when the switch E.C.U. decoder E.C.U. decoder receives
control fr om the
doors’ locking switch
14. Co mmunication E.C.U .decoder - 14D =activation of the doors ACTIVE doors when
doors ac tuators actuators the E.C.U. decoder
sends the command
blocking/unlocking to
the actuators of the
doors.
15. The state of the doors contact 16G = doors contact ACTIVE when the front doors are opened.
NOTE: the state
ACTIVE occurs also
if front hood or hatchback
are opened when the
vehicle is equipped
with anti intrusion system
16. Remote controls synchronisation in 17G =programming in progress ACTIVE when the process or resynchronisation TIR/ TRF remote control
resynchronisation
procedure is in pr ocess
17. RF remote controls synchronisation 17D = not performed TIR ACTIVE when the
not perfor med programming remote control
synchronisation is not
performed.
18. Not performe d key code programming 19G = unperformed key ACTIVE when the
programming key programming is
not pe rformed
19 . Validated key code programming 19D = unblocked key programmi ng ACTIVE when the
validation of the key
programming is not
performed
20 . Th e pr og ramming of the first key 18G = the memorising of the ACTIVE when the
first key programming of the
fir st key is in process
DIAGNOSTIC
vnx.su

Page 509 of 933

82B
HORN - ENGINE IMMOBILISER
82B - 42
The anti intrusio
n system may be activated or deactivated by pushing the button of the RF remote
control of the vehicle key and it is achieving the peripheral protection of the vehicle and the volumetric
protectio n of the cockpit. The activation of the system is indicated on the instru ment panel by the LED
indicator, which will start to blink, and is confirmed by two blinks of the turning lights. Deactivation is
confirmed by a blink of the turning lights and LED indicator switching off.
In case of the vehicles equipped with central locking system, the doors will lock when the system
is activated and will unlock when deactivating the anti intrusion system. After 40 seconds from
remote control activatio n, the opening of a door, of the hood or the hatchback will cause the siren
starting and turning lights blinking for 30 seconds; after 30 seconds, the system remains activated.
During those 40 seconds, the volumetric sensors will “read” the volume of the cockpit, this
“reading” being reinitialised on every activation of the system, in order to take into account the
potential volume modifications. Any modifications of the inner volume of the cockpit ( broken
w indow glass, intrusion in the cockpit or movement inside the cockpit) will perturb the ultra-
sound emission field causing the siren starting.
The system does not normally operate unless all doors, the engine hood, the hatchback and
the window glasses are properly closed. If one of the front doors, the engine hood or the hatchback
is not well c losed, at the doors locking with the RF remote c ontrol, the t urning lights will not
switch on at all. At the deactivation with RF remote control, the traffic indicators will switch on,
just once.
AT TENT ION
In case of one door opening by key, while the anti intrusion system is
activated, the siren will start and it can be stopped by pressing the remote button or by
introducing the PIN code which is written on the vehicle invoice.
SY STEM FUNCTIONNING
vnx.su

Page 510 of 933

82B
HORN - ENGINE IMMOBILISER
82B - 43
THE PIN CODE
The PIN code is formed of four figures and it can be used only for deactivating the anti intrusion
s ystem, if this operation can not be performed by pushing the deactivating button from the RF
remote control of the vehicle. For introducing the PIN code, perform as follows:-set on the contact key in the M position and take it off it for three times in seven seconds,
after which the anti intrusion LED indicator will switch on for three seconds; -set on the contact again on the M position and maintain it until the number of the L ED
blinks is e qual with the first figure of the PIN code, then take off the contact; -set on the contact in the M position and maintain it until the number of LED blinks is equal
w ith the second figure of the PIN code, then take off the contact;
-perform the above mentioned method in order to introduce the third and the fourth figure
of the PIN code;
-after that, the system is deactivated and the siren stops automatically;
- set on the contact again – the anti LED indicator must switch on, confirming in this way
that the c orrect introduction of the PIN code.
AT TENT ION
If it i s necessary the checking of the PIN code, t his will be pe rformed
only after al least 20 seconds have passed, since the anti intrusion ECU has been
connected to the vehicle’s wiring or since the connecting of t he vehicle’s battery.
The COBRA anti intrusion system can operate in t hree different modes (2,3 or 4).
For the Super Nova vehicles, the system has been programmed to work in the second operation
mode. If by mistake the PIN code was introduced in less than 20 seconds since the battery
connecting or since connecting the anti intrusion ECU, this can involve the change of the operation
way of the system, which will generate errors during the operation. There is, although, the possibility
of reprogramming the correct operation way (type 2) and in this purpose, perform the following
operations : - disconnect and then reconnect the anti intrusion ECU; when connecting the anti intrusion
ECU the anti intrusion LED indicator will switch on once, confirming the correct connecting;
-af ter at least 5 seconds from the previous operation, but no more than 20 second from it,
perform the following operation s:
-s et on the contact key in the M position for three times and then release it;
- the anti intrusion LED indicator will switch on for three seconds and then will switch off;
- set on again the contact key in the “M” position and maintain it, counting two blinks of the
anti intrusion LED indicator, then take off the contact;
- the LED indicator will blink for two times in two series, confirming in this way the proper
performance of the previous operations;
press the doors locking button of the dashboard, in order to lock and unlock the doors; the anti
intrusion LED indicator must not blink;
vnx.su

Page 511 of 933

82B
HORN - ENGINE IMMOBILISER
82B - 44
This cycle indicating the aggression type, stops after setting on the contact.
THE SYSTEM’S MEMORY
If after the deactivating command of the system, the turning lights will blink four times and a
sound will be heard also four times, this proves that previous the deactivating, an active cycle of
the system has t aken place and the reason for it will be shown by the LED indicator as follows:
TEMPORARY CANCELLING OF THE VOLUMETRIC PROTECTION
In case you want to let a window glass partially opened or a passenger remains in the vehicle,
it is possible to temporary cancel the volumetric protection function, but the peripheral protection
remains active. Proceed as follows:
- set on the contact key in the M position and then take it off, in no more than seven
seconds; - get off the ve hicle a nd press once the button of the remote c ontrol, in no more t han 20
seconds. The volumetric protection is again active after the next locking of the doors using the remote
control.
LED indicator
1 blink
3 blinks
4 blinks
8 blinksCause
Engine hood, door or hatchback opening
V olumetric detection
St arting attempt detected
Errant communication with the siren
-get off the vehicle and press the button of the RF remote control – the doors of the vehicle
will lock and the anti intrusion indicator will start blinking, confirming that the anti intrusion system
is activated; -press again the button of the RF remote – the doors will unlock and the anti intrusion LED
indicator must switch off.
THE SYSTEM’S MEMORY
vnx.su

Page:   < prev 1-10 11-20 21-30 31-40 41-50 51-60 61-70 ... 110 next >