battery capacity DATSUN 610 1969 Workshop Manual

Page 150 of 171


The

type
D3034C
carburettor
has
certain
additional

features

These
include
a

power
valve
mechanism
to

improve
the

performance

at

high
speed
a
fuel
cut
off
valve
which
cuts
the
fuel

supply

when
the

ignition
key
is
turned
to
the
off
position
and
an

idling

limiter
to

maintain
the

emissions
below
a

certain
level

Sectional
views
of
the
two

types
of

pumps
are
shown
in

Figs
8
1
and
B
2
An
EP
3
electrical
fuel

pump
is

located
in
the

centre

of
the
spare
wheel

housing
in
the
boot

Fig
B
3
shows
a

sectional
view
of
the

pump
with
its
contact

the
pump
mechanisms

solenoid

relay
and
built
in
filter

The
air
cleaner
uses
a

viscous

paper
type
element
which

should
be

replaced
every
40
000
km
24
000
miles

Cleaning

is
not

required
and
should
not
be

attempted

The

cartridge
type
fuel
strainer

incorporates
a
fibre
clement

which
should
be
renewed
at
inervals
not

exceeding
40
000
km

24
000
miles
Fit
B
4
shows
a
sectional
view
of

the
assembly

The
fuel
lines
should
not
be
disconnected
from
the
strainer
when

the
fuel
tank
is
full

unless
absolutely
necessary
as
the
strainer

is
below
the
fuel
level

FUEL
PUMP

Testing

Disconnect
the
fuel
hose
from
the

pump
outlet
Connect

a
hose
with

an
inner
diameter
of
approximately
6
mm
0
024

in
to

the

pump
outlet
and

place
a

container
under
the
end
of

the

pipe
Note
that
the
inner

diameter
of
the

pipe
must
not
be

too

small
or

the
pipe
will
be

incapable
of

delivering
the
correct

quantity
of
fuel
when

testing
Hold
the
end
of
the
hose
above
the

level
of
the

pump
and

operate
the

pump
for
more
than
IS

seconds
to
check
the

delivery
capacity
The

capacity
should
be

I
400
cc

3
24
U
S

pts
in
one
minute
or
less
The

pump
must

be
removed
from
the
vehicle
if
it
does
not

operate
or
if
a

reduced

quantity
of
fuel
flows
from
the
end
of
the
hose
Remove

the
pump
from
the
vehicle
and
test
as
follows

Connect
the

pump
to
a

fully
charged
battery
If
the

pump

now

operates
and

discharges
fuel

correctly
the
fault
does
not

lie
in
the

pump
but

may
be
attributed
to

any
of
the

following

causes

Battery
voltage
drop

poor
battery
earth
loose

wiring

loose
connections
blocked
hoses
or
a

faulty
carburettor

If
the

pump
does
not

operate
and

discharge
fuel
when

connected
to
the

battery
then
the

pump
itself
is

faulty
and

must
be
checked
as
follows

First
make
sure
that
current
is

flowing
This
will
be
indica

ted

by
sparking
at

the
tenninals
If
current
flows
the
trouble
is

caused

by
a

sticking

pump
plunger
or

piston
The

pump
must

be
dismantled
in

this
case
and
the

parts
thoroughly
cleaned
in

petrol

If

the
current
does
not
flow
a
coil
or
lead
wire
is
broken

and
the

pump
must

be
renewed
A

reduced
fuel
flow
is
caused

by
a

faulty
pump
inlet
or

discharged
valve
or
blocked
filter

mesh
The

pump
must

of
course

be
dismantled
and
serviced
as

necessary

FUEL
PUMP

Removing
and

Dismantling

Remove
the
bolts

attaching
the
fuel

pump
cover
to

the

floor

panel
see

Fig
B
S
Remove
the
bolts

attaching
the

pump
to
the
cover

2
Disconnect
the
cable
and
fuel
hoses
Withdraw

the

pump
Dismantle
as
follows

Slacken
the

locking
band
screws
and

remove
the
strainer

strainer

spring
filter
strainer
seal
and

locking
band

Remove
the

snap
ring
Withdraw
the
four
screws
from
the

yoke
and
remove

the
electromagnetic
ulJ
it
Press
the

plunger
down
and
withdraw
the
inlet
vaive

the

packing

and
the
cylinder
and

plunger
assembly

A
defective
eledrical
unit

cannot
be
dismantled
as

it
is

sealed
and
must

be
renewed
as
a

complete
unit

FUEL
PUMP

Inspection
and

Assembly

Wash
the
strainer
filter
and

gasket
in

petrol
and

dry
using

compressed
air
Renew
the
filter
and

gasket
if

necessary
Note

that
the
filter
should
be
cleaned
every
40
000

km
24
000

miles
Wash
the

plunger
piston
and
inlet
valve
in

petrol
and

make
sure
the

piston
moves

smoothly
in
the

cylinder
Replace

the

parts
if
found
to
be
defective

Insert
the

plunger
assembly
into
the

cylinder
of
the
electri

cal
unit
and
move

the

assembly
up
and
down
to

make
sure
tha
t

the
contacts
are

operated
If
the
contacts
do
not

operate
the

electrical
unit
is

faulty
and
must

be
renewed

Assembly
is
a
reversal
of

the
dismantling
procedures
tak

ing
care
to
renew
the

gaskets
as

necessary

CARBURETIOR

Idling
Adjustment

The
D3034C
carburettor
fitted
to

engines
equipped
with

an
emission
control

system
must
be

adjusted
as
described
under

the

heading
IGNITION
TIMING
AND
IDLING
SPEED
in
the

section
EMISSION
CONTROL
SYSTEM

Reference
should
be
made
to
carburettor

idling
adjustment

procedures
for
the
L14
L16

and
LI8

engines
when

adjusting

the
type
DAK
340
carburettor
fitted
to
the
G
18

engine
A
smooth

engine
speed
of

approximately
550

rpm
should
be
attained
in

this
case

FUEL
lEVEL

Adjustment
DAK
340earburettor

A
constant
fuellevcl
in
the
float
chamber
is
maintained

by

the
float
and
needle
valve
See

Fig
8
6
If

the
fuel
level
does
not

correspond
with
the
level

gauge
line
it
will
be

necessary
to

care

fully
bend
the
float
seat
until
the
float

upper
position
is

correctly

set

The
clearance
H
between
valve
stem
and
float
seat

should

be
I
5
mm
0
0059
in
with
the
float

fully
lifted

Adjustment

can
be
carried
out

by
carefully
bending
the
float
stopper
3

FUEL
lEVEL

Adjustment
D3034Ccarburettnr

The
fuel
level
should

correspond
with
the
level

gauge
line

Adjustment
can

be
carried
out
if

necessary
by
changing
the

gaskets
between
the
float
chamber

body
and
needle
valve
seat

The
gaskets
are
shown
as
item
4
in

Fig
B
7
When

correctly

adjusted
there
should
be
a

clearance
of

approximately
7
mm

0
027
in
between
float
and
chamber
as
indicated

STARTING

INTERLOCK
VALVE
OPENING

The

choke
valve
at
its

fully
closed
position
automatically

opens
the
throttle
valve
to
an

optimum
angle
of
14

degrees
on

the

type
DAK
340
carburettor
and
13
5

degrees
on
the
D3034C

carburettor
With
the
choke
valve

fully
closed
the
clearance

G

I
in

Fig
8
should
be
1

I
mm
0
0433

in
This
clearance

S19