display GEELY CK 2008 User Guide

Page 303 of 392

296VII. Fill the liquid and bleedAfter replacing the HECU, bleed the second HECU circuit in addition to the filling and bleeding of the regular
brake system. Use the scan meter to perform the following procedure:Fill the fluid and bleed based on the regular brake system
until there is no air bubble in the transparent hoseConnect the scan meter with the diagnostic interfaceSelect function 04, Press OK button to confirmDepress the brake pedal and keep the hydraulic cylinder pushrod reboundRelease the brake pedal, loosen the left and right brake caliperbleeder screw, press "" buttonDepress the brake pedal 10 times, tighten the left and right
brake caliper bleeder screw, press "" buttonRepeat the above I II III steps 7 times and press "" buttonThe screen display the end of the bleed, press
"" button to return to "function selection" menuSelect function 06, Press OK button to confirm, quit the
diagnostic modeEnd →↑

Page 348 of 392

3417.Intermediate Instrument Panel Removal/Installation
(1) Disconnect the negative (--) terminal cable from the battery.
(2) Remove intermediate instrument panel.
(3) Remove the screw.
(4) Using the flat screwdriver wrapped with vinyl tape, disconnect
the clip.
(5) Pull the intermediate instrument panel forward and then remove
the clip.
(6) Remove LDC (Liquid Crystal Display) component connector.
(7) The installation is in the reverse order of the removal.
8.Glove Compartment Removal/Installation
(1) Open the glove compartment;
(2) Pull the glove compartment up and separate it from the instrument panel;
(3) The installation is in the reverse order of the removal.