air condition GEELY FC 2008 User Guide

Page 226 of 419

Refrigerant
Inspection on automobile
1. Inspection of refrigerant quantity
Observe the visible window on high pressure liquid pipe.
Testing condition:

¡ñ¡ñ
¡ñ¡ñ¡ñ
Engine runs at the speed of about 1500 rpm.

¡ñ¡ñ
¡ñ¡ñ¡ñ
Fan speed is controlled at “HI” position.

¡ñ¡ñ
¡ñ¡ñ¡ñ
A/C switch turns to ON.

¡ñ¡ñ
¡ñ¡ñ¡ñ
Temperature control turns to “MAX. COOL” position.

¡ñ¡ñ
¡ñ¡ñ¡ñ
Automobile doors are opened.
Air conditioner--Refrigerant
Item Phenomenon Refrigerant quantity Verify
1There is air bubble on window. Lack (1)Use leakage measurer to check whether there is any leakage,
if necessary, repair it.
(2)Add refrigerant until air bubble disappears.
2 There is no air bubble on window. Without, full or too full Referring to item 3 and 4.
3There is no temperature difference on Without or little (1)
Use leakage measurer to check whether there is any leakage, if necessary, repair it.
outlet and inlet of compressor (2)Add refrigerant until air bubble disappears.
4There is obvious temperature difference Applicable or too much Referring to item 5 and 6.
on outlet and enter of compressor.
5Window becomes clear after air Too much (1)Reclaim refrigerant.
conditioner is closed. (2)Exhaust air and supply applicable clean refrigerant.
6After air conditioner is closed, refrigerant Applicable -
makes bubble, then becomes clear.
*When environment temperature is normal and refrigerant is enough, it is normal when there is no
bubble in window.
2. Use filling instrument package to check the refrigerant pressure.
This is a type to use filling pressure meter to check the malfunction position. In following situations, read
the meter.
Testing condition:
zSwitch is set up at inner air cycle, and the inlet temperature is 30-50°C.
zEngine runs at the speed of 1500 rpm.
zSet up the speed control switch of fan at “HI” position.
zTemperature control switch is set up at “COOL” position.
zA/C switch turns to “ON”.
zAutomobile door is opened completely.
Hint:please pay attention to that the show of meter might change little for environment tem-
perature changes.
View window
 215 

Page 227 of 419

(1) Refrigerant system with normal function.
Meter reading
Low pressure end:
0.15-0.25Mpa
High pressure end:
1.37-1.57Mpa
(2) Water in cooling system.
Air conditioner--Refrigerant
When cooling system is
working, the pressure in low
pressure end changes to
vacuum or normal periodically.Water vapor enters refrigerant
system, and freezes on the ex-
pansion valve, the system
stops cycle in short time, when
ice melts, it returns to normal
again.(1)Change the condenser.
(2)Remove water in pipeline
with method of taking out
vacuum repeatedly.
(3)Fill applicable new
refrigerant.zDryer locates at full humidity
state.
zWater vapor of refrigerant
freezes on the outlet orifice
of expansion valve to ob-
stacle freezing cycle.
Phenomenon Possible reason Diagnose Method
(3) Lack refrigerant
Situation: too cold periodically, then lose cooling degree.
zThe pressure of high and low
pressure end is low.
zThere is air bubble on
window.
zRefrigerant leaks.Some part of refrigerant system
leaks.(1)Check it with leakage
measurer, if necessary, re-
pair it.
(2)Fill refrigerant to applicable
quantity.
(3)If meter pressure reading is
0, after checking and repair-
ing leaking position, take out
vacuum.
zRefrigerant in system lacks.
zCooling degree is not
enough.
Phenomenon Possible reason Diagnose Method
State: lack refrigerant
 216 

Page 228 of 419

Air conditioner--Refrigerant
zThe pressure of high and low
pressure end is low.
zThe pipeline from condenser
to expansion valve frosts.
zRefrigerant flow in adjuster
is obstructed by impurity.zChange the condenser.zAdjuster is obstructed.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough(4) Refrigerant cycle is poor
(5) Refrigerant does not have any cycle.
zLow pressure side is
vacuum, and pressure at
high pressure side is low.
zThe pipeline of front and
rear end of expansion
valve or adjuster frosts or
dews.
zRefrigerant flow in cool-
ing system is obstructed
by water vapor or dust.
zRefrigerant flow is ob-
structed by expansion
valve.(1)Check the expansion
valve.
(2)Remove the dirt in ex-
pansion valve with high
pressure air.
(3)Change condenser.
(4)Take out vacuum and fill
applicable refrigerant.
(5)If this is caused by ex-
pansion valve leakage,
change the valve. Refrigerant does not flow.
Phenomenon Possible reason Diagnose Method
State: not cool (sometime cool)
 217 

Page 229 of 419

Air conditioner--Refrigerant
zThe pressure of high and
low pressure end is high.
zThere is no bubble on
window when engine
speed decreases.
zToo much refrigerant in
system incurs this.
zHeat dispersion of con-
denser is bad.(1)Clean the condenser.
(2)Check the function of
cooling fan.
(3)If those two items above
are normal, check the re-
frigerant quantity. Fill
applicable refrigerant.
zFilled refrigerant is too
much.
zHeat dispersion of con-
denser is bad¡ú¡ú
¡ú¡ú
¡úheat dis-
persion sheet of con-
denser is obstructed or fan
engine has malfunction.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough.
zThe pressure of high and
low pressure end is high.
zPipeline of low pressure
end is too hot to contact.
zThere is bubble on
window.Air enters cooling system. (1)Check whether the Re-
frigerant oil is too dirt or
lack.
(2)Take our vacuum and fill
new refrigerant.
zThere is air in cooling
system.
zIt does not take out
vacuum completely.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough.(6) Refrigerant is too much or the radiating fin of condenser is bad
(7) Air enters cooling system
Note: i f cooling system is
opened, and it does not
take out vacuum when
filling refrigerant, this
state will happen.
 218 

Page 230 of 419

Air conditioner--Refrigerant
zThe pressure of high and low
pressure end is high.
zPipeline of low pressure end
frosts or dews heavily.Expansion valve has
malfunction.Check the expansion valve. zRefrigerant in low pressure
pipeline is too much.
zOpen degree of expansion
valve is too big.
Phenomenon Possible reason Diagnose Method
State: cooling degree is not enough
zThe pressure of low pressure
end is too high.
zThe pressure of high pres-
sure end is too low.There is inner leakage in
compressor.Repair or change the
compressor. zCompressor is bad.
zExpansion valve leaks or
sliding part is damaged.
Phenomenon Possible reason Diagnose Method
State: not cool(8) Expansion valve is bad
(9) Not cool
 219 

Page 231 of 419

Air conditioner--Refrigerant
Reading of filling meter (referred value)
 220 
Pressure of low pressure side
Fan “HI” phase
Blower “LO” phase
Pressure of high
pressure side

Page 232 of 419

Change
1. Reclaim HFC-134a (R134a)
(a) Turn A/C switch to ON.
(b) Keep the engine speed at 1000 rpm, and rotate cooling compressor for 5 to 6 minutes to make
refrigerant cycle, this could collect the Refrigerant oil in each part in cooling compressor as possible.
(c) Extinguish the engine.
(d) Drain the refrigerant.
2. Fill refrigerant
(a) Use vacuum pump to take out vacuum.
(b) Fill the refrigerant HFC-134a (R134a)
Standard quantity: 660 ± 10g
3. Heat the engine
4. Check whether the refrigerant leaks.
Air conditioner--Refrigerant
 221 
Bubble
disappearing
pointToo much filling refrigerant Increase 100g Filling quantity of refrigerant
Pressure at
the high
pressure side
Refrigerant quantity
Auxiliary condenser system
Applicable
filling scope

Page 233 of 419

Air conditioner--Refrigerant pipeline
Refrigerant pipeline
Parts
.
 ::
:::
Regulated torque
 222 
¹Ü¹Ü
¹Ü¹Ü¹Ü··
···ÂÝÂÝ
ÂÝÂÝÂÝĸĸ
ĸĸĸ
Refrigerant low
pressure hose
Pipeline nut
Refrigerant high
pressure hose
Refrigerant liquid pipe

Page 234 of 419

Air conditioner--Control assembly, air conditioner control panel (AUTO A/C)
Overhaul
1. Disassemble central wind outlet trim board of panel.
2. Disassemble decoration panel assembly of shift
organization. [68000076]
3. Disassemble central storage box.
4. Disassemble control panel assembly of air
conditioner. [67000148]
5. Disassemble control assembly and control panel
assembly of air conditioner.
(a) Disassemble ten screws.
(b) Disconnect four fixed claws and disassemble control as-
sembly and control panel of air conditioner.
6. Disassemble control box of air conditioner.
Disconnect flat linking wire and disassemble control box of
air conditioner.
7. Disassemble electric circuit board of air conditioner
control module.
(a) Disassemble two screws.
(b) Disassemble electric circuit board from air conditioner con-
trol box.
8. Disassemble control panel wiring of air conditioner.
(a) Disassemble two screws.
(b) Disassemble control panel wiring of air conditioner from
air conditioner control box.
9. Disassemble control box assembly of air conditioner.
10. Disassemble switch bulb of air conditioner control
panel.
11. Disassemble control button assembly.
12. Disassemble NO.2 warm control button
Fixing claw
 223 
Control assembly, air conditioner control panel
(AUTO A/C)

Page 235 of 419

Fan assembly
Overhaul
1. Disassemble left/right front door pedal trim board.
2. Disassemble front lower inner trim board at the left/
right side.
3. Disassemble storage box assembly at the right side
of panel.
4. Disassemble engine ECU.
(a) Disassemble two fixed clamps and engine ECU cover.
(b) Disassemble two screws and disconnect engine ECU.
5. Disassemble panel assembly.
(a) Disassemble the bolts and screws from panel.
(b) Disassemble the screws and air conduct.
6. Disassemble fan assembly.
(a) Disassemble fixed clamp and turn over the carpet.
(b) Disassemble fixed claw and disconnect joint plug.
Air conditioner--Fan assembly
Fixing claw
 224 
Carpet

Page:   < prev 1-10 11-20 21-30 31-40 41-50 50 next >