plug GREAT WALL SAFE 2006 Owner's Guide

Page 344 of 484

BE-66
Mount of bass speaker and VCD
(a) bass speaker
Connect the audio output wires of bass speaker with the sockets in bass speaker correspondingly according
to the wire color (red plugging element should be plugged in red socket, yellow plugging element in white
socket, the grounding wire (black), power wire (yellow) and signal wire (blue) should be fixed at the
corresponding positions (GND12VREM) on bass speaker tightly.
(b) multi-disc VCD
The feed cables of VCD main device should be connected as marked, when connecting the plugging element
of wire harness of video camera (CAM) with the plugs on main device (CAM), notice should be taken on the
two arrow marks so as to prevent the plugging element damage; The audio output wire plugging elements (red
and yellow plugs) of bass speaker should be connected with the red and white sockets of mainframe (AV OUT);
the plugging elements of TV receiving input wire of amplifier should be connected with either of the plugging
elements(AV AN) of the mainframe; the plugging element (black and white ACC) of anode wire of power
supply should be connected with the red socket (ACC) of mainframe wire harness; grounding wire plugging
element (black GND) should connect with the black socket of mainframe wire harness; the plugs of audio input
wire of deci-disc data converter should be connected with the red and white socket on mainframe according
to the plugs color (the plugs (red, white CD OUT) of audio input wire of eight-disc box should be connected
with the red, white socket (CD IN) on mainframe according to the plug color, the yellow power wire plugging
element (BATT) should be connected with the yellow power wire socket (BATT) on mainframe, the electric
aerial, plugging elements of control wire of function amplifier should be connected with the electric aerial
(CTL), socket of control line of function amplifier on mainframe. After completing the connection of plugging
elements, wrap the connecting position with adhesive strap in order to prevent those plugging elements from
peeling off, the plugging element of feed cable of TV receiving aerial can connect with any two of the four
holes on amplifier, meanwhile, turn on the switch (with a red indicating lamp) of amplifier when watching the
TV play. When mounting the VCD mainframe, push the wire harness innermost as can as possible so that there
is spacious room for mainframe, then push in the mainframe, notice should be taken not to damage the wire
harness. Fasten the mainframe to the degree that it cannot be pull out by hand after assembling, if it cannot be
clamped tightly, prize out the two clips on the inner sleeve, then fasten the mainframe, and mount on the
external decoration frame finally. When disassembling the mainframe, tear down the external decoration
frame first, then insert the special key into the open grooves at two sides to pull out the mainframe.Body Electric SystemAcoustical Equipment System

Page 349 of 484

BE-71
Cab wire harness

1 right front turn lamp
2 outdoor temperature sensor
3 right lever-shaped lamp
4 front fog lamp
5 horn
6 accumulator wire of 220V
7 electromagnetic fan
8 temperature control switch
9 protective box II
10 turn signal lamp on right side
11 brush motor
12 plug of engine wire harness
13 wire harness at right rear door
14 plug of frame wire harness
15 door lamp switch
16 wire harness at right front door
17 door lamp
18 right external electric rear vision mirror
19 protective box III
20 indoor temperature sensor
21 right loudspeaker22 speed-adjusting resistance
23 air blower
24 grounding wire
25 A/C switch
26 controlling element
27 ashtray lamp
28 receiver wire
29 cigarette lighter
30 cigarette lighter
31 rear sound box wire
32 amplifying plate of air-conditioner
33 grounding wire
34 heat-sensitive resistance
35 dual flasher switch
36 fog lamp switch
37 temperature indicator
38 combined switch shell lamp
39 combined switch
40 ignition switch
41 combination instrument A
42 combination instrument B43 parking brake switch
44 brake switch
45 left loudspeaker
46 control case of central control lock
47 grounding wire
48 grounding wire
49 voltage regulator
50 brake liquid level alarming device
51 protective box I
52 plug of wire harness at left rear door
53 door lamp
54 door lamp switch
55 ceiling lamp
56 lamp for reading
57 door lamp
58 door lamp switch
59 backup radar screen
60 right rear loudspeaker
61 highly-mounted stop lamp
62 left rear loudspeaker
1
2
34
5 6
789 10111213
14
15
16
17
18
19
20
2122
23
2425
26
27
28
29 30313233
34
35
36
373839
40
41
4243
4445
4647
48
4950
5152 53
54
55
56
5758 59
60
61
62
Body Electric SystemWire Harness Distribution

Page 365 of 484

AC-2Air Conditioning SystemIntroduction
In case the liquid refrigerant enters into the eye or touches the
skin, the following measures shall be taken:
Wash the part where is touched by the refrigerant with a
great deal of water.
Coat the skin with the clean Vaseline.
See the doctor or go to the hospital for treatment; and
Do not try to cure it yourself.
General Introduction
1. Take notice when handling refrigerant General Introduction
(a) Do not handling with refrigerant in the closed room or
near to open fire.
(b) Safety goggles shall be worn when handling
(c) Be careful to avoid the liquid refrigerant from entering
into your eye or touching you skin.
waterair
dust
ÅçåÇÉåëÉêplug
2. Take notice when changing the parts of refrigerant pipes:
(a) The refrigerant shall be exhausted gradually before
changing.
(b) The dismantled parts shall be covered with plug right
away so as to prevent the water or dust from entering into
the system.
(c) Do not store the condenser or liquid tank under the
condition that the plug has been uncovered. and
(d) Refrigerant shall be exhausted before installing the new
condenser, because the refrigerant, if not exhausted, will
eject out in gaseous form with the lubricant oil when the
plug is moved away.
3. Take notice when fastening the connection parts:
(a) Spread a little lubricant oil at the matching position of the
O-type ring to fasten the connection and avoid of gaseous
refrigerant leakage.
(b) Fasten the nut with two spanners so as to avoid of the pipe
deformation.

Page 373 of 484

AC-10Air-conditioning System - Troubleshooting
Troubleshooting
TroubleReparation approachesPage
Lack of cold airNon-pull-in performance of electromagnetic clutch:
(a) Break of ignition switch and fuse;
(b) Trouble of electromagnetic clutch;
(c) Trouble of A/C switch;
(d) Wiring or grounding trouble;
(e) Lack of refrigerant; and
(f) Trouble of pressure switch.
Abnormal operation of compressor:
(a) Looseness or break of driving belt;
(b) Compressor trouble;
Expansion valve trouble;
Systematic leakage;
Liquid tank fusible plug melting or filtering
screen blocking;
Non-work of air blower:
(a) Failure of A/C switch;
(b) Failure of air blower motor, and
(c) Wiring failure.Change the fuse and check to see whether
there is short circuit;
Check the electromagnetic clutch;
Check the A/C switch;
Repair it as requirement;
Check the refrigerant pressure;
Check the pressure switch;
Adjust or change the driving belt;
Check the compressor;
Check the expansion valve;
Conduct lubricating test for the system
Check the liquid tank;
Check the A/C switch;
Check the air blower motor;
Conduct reparation as requirement.
Inconsecutive
cold airElectromagnetic valve slip
Failure of expansion valve;
Wiring or connecting failure;
Over water content in systemCheck the electromagnetic clutch;
Check the expansion valve;
Make reparation as requirement.
Reclaim the water first, then exhaust the
system to vacuum and inflate in the refrigerant.
Cold air occurs in
high-speed conditionBlocking of radiating face of condenser;
Driving belt slip;
Compressor failure;
Insufficient or redundant refrigerant;
Air existing in systemCheck and wash the condenser
Check and change the driving belt;
Check the compressor;
Check the refrigerant quantity;
Vacuumize the system and inflate
the refrigerant;
Insufficient
cold airCondenser blocking;
Driving belt slip;
Electromagnetic clutch failure;
Compressor failure;
Expansion valve failure;
Insufficient or redundant refrigerant;
Air existing in system;
Redundant compressor lubricant;
Liquid tank blockCheck the condenser;
Check and change the driving belt;
Check the electromagnetic clutch;
Check the compressor;
Check the expansion valve;
Check the refrigerant quantity;
Reclaim the air, then vacuumize the sys-
tem and inflate the refrigerant;
Check the compressor lubricant quantity;
Check the liquid tank
Evaporator blocking or frosting
Air leakage in cooling device or air
pipeline;
Air inlet blocking;
Air blower motor failure;Clean the evaporator radiating rib
or filter;
Make reparation as requirement
Make reparation as requirement
Change the air blower motor.
Page AC-4 to 7
Page AC-12
Page AC-4 to 7
Page AC-11
Page AC-13
Page AC-12
Page AC-16
Page AC-14
Page AC-4 to 7
Page AC-12
Page AC-16
Page AC-4 to 7
Page AC-15
Page AC-12
Page AC-12
Page AC-12
Page AC-16
Page AC-11
Page AC-14
Page AC-18
Page AC-20
Possible causes
Page AC-15
Page AC-13
Page AC-12
Page AC-11
Under-speed cold air

Page 377 of 484

AC-14Air-Conditioning System Liquid Tank
Liquid Tank
Check to see whether there is leakage in observation window,
fusible plug and joints;
Conduct the inspection with the gas leakage detector and, if
necessary, repair or change the liquid tank.
Dismantle of Liquid Tank
1. Exhaust the refrigerant;
2. Tear down the two liquid pipes from the liquid tank;
Remark: the opened joint should be plugged with cork so as to
prevent the humid air from entering into the system.
3. Tear down the liquid tank from the tank bracket.
Mount of Liquid Tank
1. Mount the liquid tank on the liquid tank bracket;
Remark: the cover of joint should not be take down before
connecting the pipe;
2. Connect the two liquid pipes to the liquid tank;
Tightening moment(See page AC-8)
3. Vacuumize the system and inflate the refrigerant in;
Vacuumizing time:
Dr SL SK SF SJVacuumize for 20 min and main-
tain the pressure for 30min;
SYVacuumize for 30 min and maintain the pres-
sure for 30min.
4.
Dr(600-650)g
SL7000g
SK SJ5600g
SF(700-720)g
SY8500g
liquid pipe
condenser
liquid tank
liquid pipe
liquid pipe liquid pipe
liquid tankcondenser
SL SK SY SJ
Dr SF

Page 378 of 484

AC-15Air-Conditioning SystemCondenser
Condenser
Condenser dismantle
1. Check the radiating ribs of condenser to see whether
there is blocking or damage;
if the radiating rib is blocked, wash it with water and dry it with
compressed air.
Notice: be careful not to damage the radiating rib;
2. Check the condenser joint to see whether there is leakage;
Make reparation as requirement;
Condenser disassembly
1. Exhaust the refrigerant;
2. Tear down the median mesh and the bonnet lock bracket;
3. Disconnect the outlet hose from the entrance joint of
condenser;
4. Tear down the liquid pipe from the outlet of liquid tank;
Remark: the opened joint should be plugged with cork so as to
prevent the humid air from entering into the system.
5. Tear down the condenser:
Tear down the two bolts.
Condenser mount
1. Mount the condenser
Screw on the two bolts so that the rubber washer contacts the
mounting flanges correctly.
2. Connect the liquid pipe to the liquid tank and the outlet
hose to the condenser.
Tightening moment(See page AC-8)
3. Mount the median mesh and the bonnet lock bracket;
4. vacuumize the air-conditioning system;
Vacuumizing time:
Dr SL SK SF SJvaccumize for 20min and main-
tain the pressure for 30min;
SYvaccumize for 30min and maintain the pres-
sure for another 30min.
5. Inflate the refrigerant in the air-conditioning system and
check to see whether there is air leakage:
Dr(600-650)g 
SL7000g
SK SJ5600g
SF(700-720)g
SY8500g
liquid pipe
condenser
liquid tank
liquid pipe
condenser
liquid tank
SL SK SY SJ Dr SF
liquid pipe outlet hose
liquid pipe

Page 379 of 484

AC-16Air-Conditioning SystemRefrigeration Device
Refrigeration device
On-vehicle inspection on expansion valve
1. Check the gaseous refrigerant quantity in the refrigeration
cycle;
2. Mount the manifold gauge;
(see Page AC-12)
3. Run the engine;
Run the engine at a speed of 2000 r/m for five minutes.
4. Check the expansion valve;
If the expansion valve is blocked, the LP readings will reduce
to 0 kPa, otherwise, the valve is normal.
Disassembly of Refrigeration Device
1. Disconnect the cathode lead from the storage cell;
2. Exhaust the refrigerant;
3. Tear down the suction pipe from the entrance joint of
refrigeration device;
4. Tear down the outlet pipe from the entrance joint of
refrigeration device;
Remark: the opened joint should be sealed with the cork to
prevent the humid air from entering into the system.
5. Tear down the insulation rings from the inlet and outlet
joints.
6. Tear down the right glove box (SY rear air-conditioner:
tear down the interior trim panel at left rear side).
7. Disconnect the plugging element;
8. Tear down the refrigeration device;
Tear down the three nuts.
refrigeration device
SYinterior trim panel
at left rear side
rear evaporator

Page 381 of 484

AC-18Air-Conditioning SystemEvaporator
SYrear evaporator
upper housing
air cover
lower housing temperature controller air blowerevaporator core air pipeheat-sensitive resistance
1. Tear down the evaporator housing:
(a) Disconnect the plugging element;
(b) Tear down the two clipes;
(c) Tear down the four screws;
(d) Tear down the upper cluster housing;
(e) Tear down the HP/LP pressure pipe rubber washers; and
(f) Tear down the lower cluster housing.
2. Tear down the expansion valve:
(a) Tear down the liquid pipe from the entrance joint of
expansion valve;
(b) Tear down the sealing washer and thermal bulb from the
suction pipe of evaporator;
(c) Tear down the expansion valve.
expansion valve
HP pipe LP pipe

Page 382 of 484

AC-19Air-Conditioning SystemRefrigeration Device
inspectionofevaporator
1. Check the radiating ribs of evaporator to see whether there is
block.
If the radiating rib is blocked, clean it with the compressed air.
Notice: do not wash the evaporator with water.
2. Check the joint to see whether there is crack or scrape.
Make reparation as requirement.
Mount the evaporator parts:
(a) Connect the expansion valve to the entrance joint of evaporator
and screw up the nuts.
Remark: Carefulness should be put on the O-ring seal.
(b) Mount the bracket on the suction pipe with thermal sensor;
(c) Connect the liquid pipe to the entrance joint of expansion
valve and screw up nuts.
(d) Mount the lower cluster housing on evaporator.
(e) Mount the upper cluster housing;
(f) Mount the four screws;
(g) Mount the two clipes;
(h) Mount the HP/LP pressure rubber washer; and
(i) Connect the plugging elements;
1. Mount the refrigeration device.
Mount the refrigeration device with three nuts.
2. Connect the plugging elements;
3. Mount the right glove box (SY rear air-conditioner: mount the
interior trim panel at left rear side).
4. Mount the insulation ring on the inlet and outlet joints;
5. Connect the liquid pipe to the outlet joint of refrigeration device;
Tightening moment(see page AC-8)
6. Connect the suction pipe to the outlet joint of refrigeration pipe;
Tightening moment(see page AC-8)
7. Connect the cathode lead to the storage cell.
8. Vacuumize the air-conditioning system:
Vacuumizing time:
Dr SL SK SF SJvacuumize for 20min and maintain the
pressure for 30min
SY: vacuumize for 30min and maintain the pressure for
another 30min.
9. Inflate the refrigerant in the air-conditioning system and
check to see whether there is air leakage;
Refrigerant quantity:
Dr(600-650)g
SL7000g
SK SJ5600g
SF(700-720)g
SY8500g
expansion valveHP pipe LP pipe

Page 392 of 484

B0-9
manual indoor plate
Electric indoor plate (Type A)
ten clips
12 clips
Vehicle BodyFront Door
12. Mount the interior trim panel of car door:
Dr)
(a) Connect the handle to the control lever first, then pull it
out from the indoor handle hole.
(b) Fix the clip by tapping to encase the interior trim plate of
car door in the corresponding hole of car door interior
panel.
(c) Use one screw to mount the inner clip.
Dr SF)
(a) Connect the handle to the control lever first, and then pull
it out from the indoor handle hole.
(b) Fix the clip by tapping to encase the interior trim panel in
the corresponding hole of car door interior panel
(c) Mount the inner clip with one screw; and
(d) Mount the electric switch and panel.
SL SK SY SJ)
(a) Connect the handle with the control lever first, then pull
out it from the indoor panel handle.
(b) Connect the plugging elements.
(c) Fix the clip by light tapping to encase the interior trim panel
of car door in the corresponding holes on indoor panel.
(d) Mount the inner clip with two bolts;
(e) Mount the four screws to fasten the interior trim panel of
car door, and cover the nuts.
(f) Mount the electric elevator switch.
13. Mount the indoor handle:
(a) Push the indoor handle into the car door paneling and
make it slide backward.
(b) Screw on the screws;
14. Mount the elevator handle (Dr)
Mount the paneling and elevator handle with spring snapping
ring under the condition the car doors and windows are closed
completely as shown in drawing.
12 clips
9. Adjust the car door and window glass;
Adjust the balance arm upwardly or downwardly until the
dimensions of A and B shown in drawing are equal, and then
fix the balance arm.
10. Mount the outer
Encase the claw of clip into the paneling seam and press the
outer on the paneling.
11. Mount the rear vision mirror
inner panel of electric door (type B)
four sets of bolt and nut
front