sensor INFINITI FX35 2004 Service Manual
Page 2150 of 4449
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-809
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
2LHeated oxygen sensor 1
heater (bank 1)[Engine is running]
Warm-up condition
Engine speed is below 3,000 rpmApproximately 7V
[Engine is running]
Engine speed is above 3,000 rpmBATTERY VOLTAGE
(11 - 14V)
PBIB0519E
Page 2152 of 4449
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-811
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureABS00C0S
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
24 BRHeated oxygen sensor 1
heater (bank 2)[Engine is running]
Warm-up condition
Engine speed is below 3,000 rpmApproximately 7V
[Engine is running]
Engine speed is above 3,000 rpmBATTERY VOLTAGE
(11 - 14V)
PBIB0519E
PBIB2195E
Page 2153 of 4449
EC-812
[VK45DE]
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S1 terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E17, F47
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HO2S1 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.Voltage: Battery voltage
PBIB1521E
PBIB0969E
DTCTerminals
Bank
ECM Sensor
P0031, P0032 2 3 1
P0051, P0052 24 3 2
Continuity should exist.
Page 2154 of 4449
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
EC-813
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
5. CHECK HEATED OXYGEN SENSOR 1 HEATER
Refer to EC-813, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace malfunctioning heated oxygen sensor 1.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-784, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionABS00C0T
HEATED OXYGEN SENSOR 1 HEATER
1. Check resistance between HO2S1 terminals as follows.
2. If NG, replace heated oxygen sensor 1.
CAUTION:
Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard sur-
face such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system
threads using Oxygen Sensor Thread Cleaner tool J-43897-
18 or J-43897-12 and approved anti-seize lubricant.
Removal and InstallationABS00C0U
HEATED OXYGEN SENSOR 1
Refer to EM-178, "EXHAUST MANIFOLD AND THREE WAY CATALYST" .
Terminal No. Resistance
2 and 3 3.3 - 4.0 Ω at 25°C (77°F)
1 and 2, 3, 4
∞ Ω
(Continuity should not exist)
4 and 1, 2, 3
PBIB0970E
Page 2155 of 4449
EC-814
[VK45DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2004 November 2004 FX35/FX45
DTC P0037, P0038, P0057, P0058 HO2S2 HEATERPFP:226A0
DescriptionABS00C0V
SYSTEM DESCRIPTION
The ECM performs ON/OFF control of the heated oxygen sensor 2 heater corresponding to the engine speed,
amount of intake air and engine coolant temperature.
OPERATION
CONSULT-II Reference Value in Data Monitor ModeABS00C0W
Specification data are reference values.
On Board Diagnosis LogicABS00C0X
Sensor Input signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)Engine speed
Heated oxygen sensor 2
heater controlHeated oxygen sensor 2 heater
Engine coolant temperature sensor Engine coolant temperature
Mass air flow sensor Amount of intake air
Engine speed rpm Heated oxygen sensor 2 heater
Above 3,600OFF
Below 3,600 rpm after the following conditions are met.
Engine: After warming up
Keeping the engine speed between 3,500 and 4,000 rpm for 1
minute and at idle for 1 minute under no loadON
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 HTR (B1)
HO2S2 HTR (B2)
Engine speed is below 3,600 rpm after the following conditions are met.
–Engine: After warming up
–Keeping the engine speed between 3,500 and 4,000 rpm for 1 minute and
at idle for 1 minute under no loadON
Engine speed: Above 3,600 rpm OFF
DTC No.Trouble diagnosis
nameDTC detecting condition Possible cause
P0037
0037
(Bank 1)Heated oxygen
sensor 2 heater
control circuit lowThe current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM
through the heated oxygen sensor 2 heater.)
Harness or connectors
(The heated oxygen sensor 2 heater circuit is
open or shorted.)
Heater oxygen sensor 2 heater P0057
0057
(Bank 2)
P0038
0038
(Bank 1)Heated oxygen
sensor 2 heater
control circuit highThe current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to
ECM through the heated oxygen sensor 2
heater.)
Harness or connectors
(The heated oxygen sensor 2 heater circuit is
shorted.)
Heater oxygen sensor 2 heater P0058
0058
(Bank 2)
Page 2158 of 4449
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-817
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
6RHeated oxygen sensor 2
heater (bank 1)[Engine is running]
Engine speed is below 3,600 rpm after the
following conditions are met
–Engine: after warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load0 - 1.0V
[Ignition switch: ON]
Engine stopped
[Engine is running]
Engine speed is above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
Page 2160 of 4449
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-819
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS00C10
1. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Repair or replace ground connections.
TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
25 PHeated oxygen sensor 2
heater (bank 2)[Engine is running]
Engine speed is below 3,600 rpm after the
following conditions are met
–Engine: after warming up
–Keeping the engine speed between 3,500
and 4,000 rpm for 1 minute and at idle for 1
minute under no load0 - 1.0V
[Ignition switch: ON]
Engine stopped
[Engine is running]
Engine speed is above 3,600 rpmBATTERY VOLTAGE
(11 - 14V)
PBIB2195E
Page 2161 of 4449
EC-820
[VK45DE]
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S2 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 2 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S2 terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, E49
IPDM E/R connector E7
10A fuse
Harness for open or short between heated oxygen sensor 2 and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HO2S2 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S2 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
PBIB1534E
Voltage: Battery voltage
PBIB0969E
DTCTerminals
Bank
ECM Sensor
P0037, P0038 6 3 1
P0057, P0058 25 3 2
Continuity should exist.
Page 2162 of 4449
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-821
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
5. CHECK HEATED OXYGEN SENSOR 2 HEATER
Refer to EC-821, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace malfunctioning heated oxygen sensor 2.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-784, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END
Component InspectionABS00C11
HEATED OXYGEN SENSOR 2 HEATER
1. Check resistance between HO2S2 terminals as follows.
2. If NG, replace heated oxygen sensor 2.
CAUTION:
Discard any heated oxygen sensor which has been dropped
from a height of more than 0.5 m (19.7 in) onto a hard sur-
face such as a concrete floor; use a new one.
Before installing new oxygen sensor, clean exhaust system
threads using Oxygen Sensor Thread Cleaner tool J-43897-
18 or J-43897-12 and approved anti-seize lubricant.
Removal and InstallationABS00C12
HEATED OXYGEN SENSOR 2
Refer to EM-178, "EXHAUST MANIFOLD AND THREE WAY CATALYST" .
Terminal No. Resistance
2 and 3 5.0 - 7.0 Ω at 25°C (77°F)
1 and 2, 3, 4
∞ Ω
(Continuity should not exist)
4 and 1, 2, 3
PBIB0970E
Page 2163 of 4449
EC-822
[VK45DE]
DTC P0101 MAF SENSOR
Revision: 2004 November 2004 FX35/FX45
DTC P0101 MAF SENSORPFP:22680
Component DescriptionABS00C13
The mass air flow sensor is placed in the stream of intake air. It mea-
sures the intake flow rate by measuring a part of the entire intake
flow. It consists of a hot film that is supplied with electric current from
the ECM. The temperature of the hot film is controlled by the ECM a
certain amount. The heat generated by the hot film is reduced as the
intake air flows around it. The more air, the greater the heat loss.
Therefore, the ECM must supply more electric current to maintain
the temperature of the hot film as air flow increases. The ECM
detects the air flow by means of this current change.
CONSULT-II Reference Value in Data Monitor ModeABS00C14
Specification data are reference values.
On Board Diagnosis LogicABS00C15
This self-diagnosis has the one trip detection logic.
NOTE:
If DTC P0101 is displayed with DTC P1229, first perform the trouble diagnosis for DTC P1229. Refer to
EC-1156
.
SEC266C
MONITOR ITEM CONDITION SPECIFICATION
MAS A/F SE-B1 See EC-780, "
TROUBLE DIAGNOSIS - SPECIFICATION VALUE" .
CAL/LD VALUE
Engine: After warming up
Air conditioner switch: OFF
Shift lever: N
No loadIdle 14% - 33%
2,500 rpm 12% - 25%
MASS AIRFLOW
Engine: After warming up
Air conditioner switch: OFF
Shift lever: N
No loadIdle 2.0 - 6.0 g·m/s
2,500 rpm 7.0 - 20.0 g·m/s
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0101
0101Mass air flow sensor cir-
cuit range/performance
problemA)A high voltage from the sensor is sent to ECM
under light load driving condition.
Harness or connectors
(The sensor circuit is open or
shorted.)
Mass air flow sensor
B)A low voltage from the sensor is sent to ECM
under heavy load driving condition.
Harness or connectors
(The sensor circuit is open or
shorted.)
Intake air leaks
Mass air flow sensor