Key cylinder INFINITI FX35 2004 Manual PDF
Page 4211 of 4449
SE-82
AUTOMATIC DRIVE POSITIONER
Revision: 2004 November 2004 FX35/FX45
Detention Switch (P Range Switch) Circuit CheckAIS002XW
1. CHECK FUNCTION
With CONSULT-II
Make sure when the A/T selector lever is in P position, “P POSITION
SW” on the DATA MONITOR becomes ON.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between drive seat control unit conductor and
ground.
OK or NG
OK >> Detention switch circuit is OK.
NG >> GO TO 2.
2. CHECK DETENTION SWITCH POWER SUPPLY CIRCUIT HARNESS
1. Key is removed form ignition key cylinder.
2. Disconnect driver seat control unit connector and A/T device
(detention switch) connector.
3. Check continuity between driver seat control unit connector
B152 terminal 17 (PU) and A/T device (detention switch) con-
nector M67 terminal 3 (R/Y).
4. Check continuity between driver seat control unit connector
B152 terminal 17 (PU) and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between driver seat control unit and A/T device (detention switch).
Monitor item
[OPERATION or UNIT]Contents
P POSITION SW“ON/
OFF”The selector lever position “P position (ON)/other than
P position (OFF)” judged from the detente switch sig-
nal is displayed.
PIIA6950E
ConnectorTerminals
(Wire color)
ConditionVoltage (V)
(Approx.)
(+) (–)
B152 17 (PU) GroundSelector lever other than P
position.Battery voltage
Selector lever sifted to P
position.0
PIIA6702E
17 (PU) – 3 (R/Y) : Continuity should exist.
17 (PU) – Ground : Continuity should not exist.
PIIA6701E
Page 4213 of 4449
SE-84
AUTOMATIC DRIVE POSITIONER
Revision: 2004 November 2004 FX35/FX45
2. CHECK KEY SWITCH AND KEY LOCK SOLENOID POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect key switch connector and key lock solenoid connec-
tor.
3. Check voltage between key switch and key lock solenoid con-
nector M22 terminal 3 (L/R) and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness between key switch and key lock sole-
noid and fuse.
3. CHECK KEY SWITCH
Check continuity between key switch as follows.
OK or NG
OK >> GO TO 4.
NG >> Replace detention switch.
4. CHECK HARNESS CONTINUITY
1. Disconnect key switch and ignition knob switch connector and
BCM connector.
2. Check continuity between key switch and ignition knob switch
connector M22 terminal 4 (B/W) and BCM connector M3 termi-
nal 37 (B/W).
3. Check continuity between key switch and ignition knob switch
connector M22 terminal 4 (B/W) and ground.
OK or NG
OK >> Key switch and ignition knob switch circuit is OK.
NG >> Repair or replace harness between key switch and ignition knob switch and BCM.3 (L/R) – Ground : Battery voltage.
PIIA5093E
Terminals Condition Continuity
3 – 4Key is inserted in ignition key cylinder. Yes
Key is removed from ignition key cylinder. No
PIIA6140E
4 (B/W) – 37 (B/W) : Continuity should exist.
4 (B/W) – Ground : Continuity should not exist.
PIIA5095E
Page 4214 of 4449
AUTOMATIC DRIVE POSITIONER
SE-85
C
D
E
F
G
H
J
K
L
MA
B
SE
Revision: 2004 November 2004 FX35/FX45
Key Switch Circuit Check (Without Intelligent Key)AIS003G1
1. CHECK KEY SWITCH
With CONSULT-II
Touch "BCM". With “IGN KEY SW” on the DATA MONITOR, Check
ON/OFF operation.
*:Refer to BL-40, "Data Monitor" .
Without CONSULT-II
GO TO 2.
OK or NG
OK >> Key switch circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH AND KEY LOCK SOLENOID POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect key switch connector.
3. Check voltage between key switch connector M23 terminal 2 (L/
R) and ground.
OK or NG
OK >> GO TO 3.
NG >> Check harness between key switch and fuse.
3. CHECK KEY SWITCH
Check continuity between key switch as follows.
OK or NG
OK >> GO TO 4.
NG >> Replace key switch.
Monitor item [OPERA-
TION or UNIT]Contents
IGN KEY SW
*“ON/
OFF”Key inserted (ON)/key removed (OFF) status judged
from the key-in detection switch is displayed.
PIIA0298E
2 (L/R) – Ground : Battery voltage.
PIIA5092E
Terminals Condition Continuity
1 – 2Key is inserted in ignition key cylinder. Yes
Key is removed from ignition key cylinder. No
PIIA6141E