fuse INFINITI FX35 2004 Manual Online
Page 1961 of 4449
EC-620
[VQ35DE]
ICC BRAKE SWITCH
Revision: 2004 November 2004 FX35/FX45
6. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between ICC brake switch and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK ICC BRAKE SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-I
1. Turn ignition switch “OFF”.
2. Check harness continuity between ICC brake hold relay terminal 3 and ICC brake switch terminal 2.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
8. CHECK ICC BRAKE SWITCH
Refer to EC-1301, "
Component Inspection" .
OK or NG
OK >> GO TO 17.
NG >> Replace ICC brake switch.
9. CHECK ICC BRAKE SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT-II
1. Turn ignition switch “OFF”.
2. Disconnect ECM harness connector.
3. Check harness continuity between ICC brake hold relay terminal 4 and ECM terminal 108.
Refer Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 11.
NG >> GO TO 10.
10. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness for open or short between ICC brake hold relay and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
11 . CHECK ICC BRAKE HOLD RELAY
Refer to EC-1301, "
Component Inspection" .
OK >> GO TO 17.
NG >> Replace ICC brake fold relay.Continuity should exist.
Continuity should exist.
Page 1962 of 4449
ICC BRAKE SWITCH
EC-621
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
12. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch “OFF”.
2. Disconnect stop lamp switch harness connector.
3. Check voltage between stop lamp switch terminal 1 and ground
with CONSULT -II or tester.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
13. DETECT MALFUNCTIONING PART
Check the following.
Joint connector-2
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between stop lamp switch and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK STOP LAMP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 101 and stop lamp switch terminal 2.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 16.
NG >> GO TO 15.
PBIB1539E
Voltage: Battery voltage
PBIB1184E
Continuity should exist.
Page 1969 of 4449
EC-628
[VQ35DE]
ASCD BRAKE SWITCH
Revision: 2004 November 2004 FX35/FX45
3. CHECK ASCD BRAKE SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect ASCD brake switch harness connector.
3. Turn ignition switch ON.
4. Check voltage between ASCD brake switch terminal 1 and
ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between ASCD brake switch and fuse
>> Repair open circuit or short to ground in harness or connectors.
5. CHECK ASCD BRAKE SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 108 and ASCD brake switch terminal 2.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E211, M41
Harness for open or short between ECM and ASCD brake switch
>> Repair open circuit or short to ground in harness or connectors.
PBIB1605E
Voltage: Battery voltage
PBIB0857E
Continuity should exist.
Page 1970 of 4449
ASCD BRAKE SWITCH
EC-629
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
7. CHECK ASCD BRAKE SWITCH
Refer to EC-631, "
Component Inspection"
OK or NG
OK >> GO TO 13.
NG >> Replace ASCD brake switch.
8. CHECK STOP LAMP SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect stop lamp switch harness connector.
3. Check voltage between stop lamp switch terminal 1 and ground
with CONSULT -II or tester.
OK or NG
OK >> GO TO 10.
NG >> GO TO 9.
9. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector E201
10A fuse
Joint connector-2
Harness for open or short between stop lamp switch and battery
>> Repair open circuit or short to ground or short to power in harness or connectors.
10. CHECK STOP LAMP SWITCH INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminal 101 and stop lamp switch terminal 2.
Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 12.
NG >> GO TO 11.
PBIB1605E
Voltage: Battery voltage
PBIB1184E
Continuity should exist.
Page 1979 of 4449
EC-638
[VQ35DE]
SNOW MODE SWITCH
Revision: 2004 November 2004 FX35/FX45
4. CHECK POWER SUPPLY CIRCUIT-I
1. Disconnect “unified meter and A/C amp.” harness connector.
2. Turn ignition switch ON.
3. Check voltage between “unified meter and A/C amp.” terminal
12 and ground under the following conditions with CONSULT-II
or tester.
OK or NG
OK >> GO TO 8.
NG >> GO TO 5.
5. CHECK POWER SUPPLY CIRCUIT-II
1. Turn ignition switch OFF.
2. Disconnect snow mode switch.
3. Turn ignition switch ON.
4. Check voltage between snow mode switch terminal 1 and
ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
10A fuse
Fuse block (J/B) harness connector M1
Harness for open or short between snow mode switch and fuse.
>> Repair open circuit or short to ground or short to power in harness or connectors.
7. CHECK SNOW MODE SWITCH OUT PUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between snow mode switch terminal 3 and “unified meter and A/C amp.” termi-
nal 12. Refer to Wiring Diagram.
3. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 8.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.
CONDITION VOLTAGE
Snow mode switch: ON Battery voltage
Snow mode switch: OFF 0V
PBIB2010E
Voltage: Battery voltage.
PBIB2011E
Continuity should exist.
Page 2028 of 4449
BASIC SERVICE PROCEDURE
EC-687
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
Idle Speed/Ignition Timing/Idle Mixture Ratio AdjustmentABS00BZD
PREPARATION
1. Make sure that the following parts are in good order.
Battery
Ignition system
Engine oil and coolant levels
Fuses
ECM harness connector
Va c u u m h o s e s
Air intake system
(Oil filler cap, oil level gauge, etc.)
Fuel pressure
Engine compression
Throttle valve
Evaporative emission system
2. On air conditioner equipped models, checks should be carried out while the air conditioner is OFF.
3. On automatic transmission equipped models, when checking idle rpm, ignition timing and mixture ratio,
checks should be carried out while shift lever is in N position.
4. When measuring CO percentage, insert probe more than 40 cm (15.7 in) into tail pipe.
5. Turn OFF headlamp, heater blower, rear window defogger.
6. Keep front wheels pointed straight ahead.
Page 2042 of 4449
BASIC SERVICE PROCEDURE
EC-701
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
2. Perform “FUEL PRESSURE RELEASE” in “WORK SUPPORT”
mode with CONSULT-II.
3. Start engine.
4. After engine stalls, crank it two or three times to release all fuel
pressure.
5. Turn ignition switch OFF.
Without CONSULT-II
1. Remove fuel pump fuse located in IPDM E/R.
2. Start engine.
3. After engine stalls, crank it 2 or 3 times to release all fuel pres-
sure.
4. Turn ignition switch OFF.
5. Reinstall fuel pump fuse after servicing fuel system.
FUEL PRESSURE CHECK
Before disconnecting fuel line, release fuel pressure from fuel line to eliminate danger.
NOTE:
Prepare pans or saucers under the disconnected fuel line because the fuel may spill out. The fuel
pressure cannot be completely released because S50 models do not have fuel return system.
Use Fuel Pressure Gauge Kit (J-44321) to check fuel pressure.
1. Release fuel pressure to zero. Refer to EC-700, "
FUEL PRESSURE RELEASE" .
2. Install the inline fuel quick disconnected fitting between fuel
damper and injector tube.
3. Connect the fuel pressure test gauge (quick connector adapter
hose) to the inline fuel quick disconnected fitting.
4. Turn ignition switch ON and check for fuel leakage.
5. Start engine and check for fuel leakage.
6. Read the indication of fuel pressure gauge.
7. If result is unsatisfactory, go to next step.
8. Check the following.
Fuel hoses and fuel tubes for clogging
Fuel filter for clogging
Fuel pump
Fuel pressure regulator for clogging
SEF214Y
PBIB1482E
PBIB1489E
At idling:
Approximately 350 kPa (3.57 kg/cm2 , 51 psi)
PBIB1490E
Page 2128 of 4449
POWER SUPPLY AND GROUND CIRCUIT
EC-787
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
3. DETECT MALFUNCTIONING PART
Check the following.
Fuse block (J/B) connector M1
15A fuse
Harness for open or short between ECM and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK GROUND CONNECTIONS
1. Turn ignition switch OFF.
2. Loosen and retighten three ground screws on the body.
Refer to EC-791, "
Ground Inspection" .
OK or NG
OK >> GO TO 5.
NG >> Repair or replace ground connections.
5. CHECK ECM GROUND CIRCUIT FOR OPEN AND SHORT-I
1. Disconnect ECM harness connector.
2. Check harness continuity between ECM terminals 1, 115, 116 and ground.
Refer to Wiring Diagram.
3. Also check harness for short to power.
OK or NG
OK >> GO TO 7.
NG >> GO TO 6.
6. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F102, M82
Harness for open or short between ECM and ground
>> Repair open circuit or short to power in harness or connectors.
PBIB2195E
Continuity should exist.
Page 2130 of 4449
POWER SUPPLY AND GROUND CIRCUIT
EC-789
[VK45DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2004 November 2004 FX35/FX45
10. CHECK ECM POWER SUPPLY CIRCUIT-V
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E7.
3. Check harness continuity between ECM terminals 119, 120 and IPDM E/R terminal 18.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 15.
NG >> GO TO 11.
11 . DETECT MALFUNCTIONING PART
Check the following.
Harness or connectors E211, M41
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
12. CHECK ECM POWER SUPPLY CIRCUIT-VI
1. Disconnect ECM harness connector.
2. Disconnect IPDM E/R harness connector E9.
3. Check harness continuity between ECM terminal 111 and IPDM E/R terminal 46.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 14.
NG >> GO TO 13.
13. DETECT MALFUNCTIONING PART
Check the following.
Harness or connectors E211, M41
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
14. CHECK 20A FUSE
1. Disconnect 20A fuse from IPDM E/R.
2. Check 20A fuse.
OK or NG
OK >> GO TO 18.
NG >> Replace 20A fuse.Continuity should exist.
Continuity should exist.
Page 2153 of 4449
EC-812
[VK45DE]
DTC P0031, P0032, P0051, P0052 HO2S1 HEATER
Revision: 2004 November 2004 FX35/FX45
2. CHECK HO2S1 POWER SUPPLY CIRCUIT
1. Disconnect heated oxygen sensor 1 harness connector.
2. Turn ignition switch ON.
3. Check voltage between HO2S1 terminal 2 and ground with
CONSULT-II or tester.
OK or NG
OK >> GO TO 4.
NG >> GO TO 3.
3. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E17, F47
Fuse block (J/B) connector E201
10A fuse
Harness for open or short between heated oxygen sensor 1 and fuse
>> Repair open circuit or short to ground or short to power in harness or connectors.
4. CHECK HO2S1 OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal and HO2S1 terminal as follows.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> Repair open circuit or short to ground or short to power in harness or connectors.Voltage: Battery voltage
PBIB1521E
PBIB0969E
DTCTerminals
Bank
ECM Sensor
P0031, P0032 2 3 1
P0051, P0052 24 3 2
Continuity should exist.