turn signal INFINITI FX35 2005 Service Manual

Page 934 of 4731

INTELLIGENT KEY SYSTEM BL-119
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
CONSULT-II FunctionsAIS004N5
CONSULT-II has display and inspection functions for work support, self-diagnosis, data monitor, and con-
trol unit part number by combining data reception and command transmission via communication lines
from the Intelligent Key unit.
CONSULT-II Inspection ProcedureAIS004N6
CAUTION:
If CONSULT-II is used with no connection CONSULT-II CONVERTER, malfunctions might be detected
in self-diagnosis depending on control unit which carry out CAN Communication.
BASIC OPERATION
1. Turn ignition knob to LOCK position.
2. Connect CONSULT-II CONVERTER and CONSULT-II to data link connector.
3. Use mechanical key to turn ignition switch to ON.
4. Touch “START (NISSAN BASED VHCL)”.
5. Touch “INTELLIGENT KEY” on “SELECT SYSTEM” screen.
If “INTELLIGENT KEY” is not indicated, go to GI-39, "CON-
SULT-II Data Link Connector (DLC) Circuit" .
Part to be diagnosed Inspection Item, Diagnosis Mode Description
Intelligent Key WORK SUPPORT
Performs Intelligent Key-ID registration, check, and deletion.
Performs steering lock unit ID registration.
Changes settings for each function (ON/OFF).
SELF-DIAG RESULTS Intelligent Key unit performs CAN communication diagnosis.
DATA MONITOR Displays Intelligent Key unit input data in real time.
ACTIVE TEST Sends drive signals door lock actuator, buzzer or combination meter
to perform operation check.
ECU PART NUMBER Displays Intelligent Key unit part No.
PBIB1503E
SKIA3098E
PIIA6737E

Page 936 of 4731

INTELLIGENT KEY SYSTEM BL-121
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
ACTIVE TEST
ACC SW [ON/OFF] Displays status (Ignition switch ACC position: ON/Ignition switch OFF position:
OFF) as judged from ignition switch signal.
DOOR STAT SW [ON/OFF] Displays status from door unlock sensor ON/OFF condition.
STOP LAMP SW [ON/OFF] Displays status (Brake pedal depress: ON/brake pedal not depress: OFF) as
judged from stop lamp switch signal.
P RANGE SW [ON/OFF] Displays status from park/neutral position switch ON/OFF condition.
BD OPEN SW [ON/OFF] Displays status (Back door open: ON/Back door closed: OFF) as judged from back
door opener switch signal.
CAN COMM [ON/OFF] Display CAN communication system.
CAN CIRC 1 [ON/OFF] Display CAN communication system.
CAN CIRC 2 [ON/OFF] Display CAN communication system.
CAN CIRC 3 [ON/OFF] Display CAN communication system.
CAN CIRC 4 [ON/OFF] Display CAN communication system. Monitor item [OPERATION] Description
Monitor item Description
DOOR LOCK/UNLOCK This test is able to check all door lock actuators lock/unlock operation. These
actuators lock when “ON” on CONSULT-II screen is touched.
OUTSIDE BUZZER This test is able to check Intelligent Key warning buzzer operation. The buzzer will
be activated on when “ON” on CONSULT-II screen is touched.
INSIDE BUZZER This test is able to check buzzer (bultin combination meter) operation. The buzzer
will be activated on when “ON” on CONSULT-II screen is touched.
INDICATOR This test is able to check warning lamp operation. The lamp will be turned on
when “ON” on CONSULT-II screen is touched.

Page 938 of 4731

INTELLIGENT KEY SYSTEM BL-123
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Trouble Diagnosis Symptom ChartAIS004N9
ALL FUNCTIONS OF THE INTELLIGENT KEY ARE NOT OPERATING
REMOTE CONTROL ENTRY FUNCTION MALFUNCTION
Symptom Diagnoses service procedure Refer to page
“KEY” and “P shift” warning lamps in combination
meter do not light up at all. 1.
Check Intelligent Key unit power supply and ground
circuit BL-129
2. Check CAN communication
BL-128
3. Replace Intelligent Key unitBL-151
“KEY” and “P shift” warning lamps in combination
meter turn on, but doors cannot be locked/
unlocked or the engine can not be started using
Intelligent Key. 1.
Use CONSULT-II to check if the Intelligent Key has
been registered Refer to
CONSULT-II Operation Manual
2. Use CONSULT-II setting change function to check if
Intelligent Key system has been cancelled BL-120
3. Intelligent Key battery inspection
BL-152
4. Replace Intelligent Key unitBL-151
Symptom Diagnoses service procedure Refer to page
Door lock/unlock does not operate (other func-
tions normal) when Intelligent Key remote con-
troller button is operated. 1. Check door lock/unlock setting
BL-120
2. Intelligent Key battery inspectionBL-152
3. Check door unlock sensorBL-136
4. Check door switchBL-133
5. Replace BCMBCS-16
6. Replace Intelligent Key unit BL-151
Driver side selective door unlock function does
not operate, when Intelligent Key remote control-
ler button is operated.
(All other remote control entry function is OK.) 1. Check selective door unlock setting
BL-120
2. Replace BCMBCS-16
3. Replace Intelligent Key unit BL-151
Panic alarm (horn and headlamp) do not acti-
vate, when panic alarm button is continuously
pressed.
(All other remote control entry function is OK.) 1. Check panic alarm mode
BL-120
2. Check headlamp functionBL-150
3. Check horn functionBL-150
4. Check IPDM E/R operationBL-150
5. Check key switch (Intelligent Key unit input)BL-129
6. Check ignition knob switchBL-132
7. Replace Intelligent Key unitBL-151
Hazard lamps do not flash during door lock oper-
ation using Intelligent Key remote controller but-
ton operated.
(Turn signal lamp operation is OK.)
(All other remote control entry function is OK.) 1. Check key reminder setting
BL-120
2. Replace BCMBCS-16
3. Replace Intelligent Key unit BL-151
Hazard lamps do not flash during door lock oper-
ation using Intelligent Key remote controller but-
ton operated.
(Turn signal lamps do not operate.) Check hazard function
BL-150
Intelligent Key warning buzzer does not sound
during door lock/unlock operation using Intelli-
gent Key remote controller button is operated.
(All other remote control entry function is OK.) 1.
Check if the operation confirmation Intelligent Key
warning buzzer was cancelled by the CONSULT-II set-
tings change function BL-120
2. Check Intelligent Key warning buzzer
BL-139
3. Replace Intelligent Key unitBL-151

Page 939 of 4731

BL-124
INTELLIGENT KEY SYSTEM
Revision: 2005 July 2005 FX
DOOR LOCK FUNCTION MALFUNCTION
Before conducting the diagnosis in the following table, check all power door lock system function. Refer to BL-
21, "POWER DOOR LOCK SYSTEM" .
Symptom Diagnoses service procedure Refer to page
Door lock/unlock does not operate when door
request switch operation is used (power door
lock system is normal). 1. Check door lock/unlock setting
BL-120
2. Check outside key antennaBL-140
3. Intelligent Key battery inspectionBL-152
4. Replace Intelligent Key unitBL-151
Door lock/unlock do not operate using door
request switch operated (power door lock sys-
tem is normal). 1. Check door switch
BL-1332. Check key switch (Intelligent Key unit input)BL-129
3. Check ignition knob switchBL-132
4. Replace Intelligent Key unitBL-151
Driver side selective door unlock function does
not operate, when door request switch is oper-
ated.
(All other door lock function is OK.) 1. Check selective door unlock setting
BL-120
2. Replace BCMBCS-16
Passenger side selective door unlock function
does not operate, when door request switch is
operated.
(All other door lock function is OK.) 1. Check selective door unlock setting
BL-120
2. Check passenger side select unlock relayBL-149
3. Replace Intelligent Key unitBL-151
Hazard lamps do not flash during door lock
operation using door request switch operated.
(Turn signal lamp operation is normal.)
(All other door lock function is OK.) 1. Check key reminder setting
BL-120
2. Replace BCMBCS-16
3. Replace Intelligent Key unit BL-151
Hazard lamps do not flash during door lock
operation using door request switch operated.
(Turn signal lamps do not operate.) Check hazard function
BL-150

Intelligent Key warning buzzer does not sound
during door lock/unlock operation using Intelli-
gent Key (regardless of whether Intelligent Key
remote controller button or request switch oper-
ation is used). 1. Check if the operation confirmation Intelligent Key
warning buzzer was cancelled by the CONSULT-II
settings change function BL-120
2. Check Intelligent Key warning buzzer
BL-139
3. Replace Intelligent Key unitBL-151
Door lock/unlock operation confirmation Intelli-
gent Key warning buzzer sounds, but door lock
actuator does not operate. (And hazard lamps
do not flash.) 1. Check CAN communication
BL-128
2. Replace Intelligent Key unitBL-151

Page 946 of 4731

INTELLIGENT KEY SYSTEM BL-131
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
Check Key Switch (BCM Input)AIS004ND
1. CHECK KEY SWITCH POWER SUPPLY CIRCUIT
1. Turn ignition knob OFF position.
2. Disconnect key switch and ignition knob switch connector.
3. Check voltage between key switch and ignition knob switch con- nector M22 terminal 3 (L/R) and ground.
OK or NG
OK >> GO TO 2.
NG >> Check harness between key switch and ignition knob switch and fuse.
2. CHECK KEY SWITCH
Check continuity between key switch and ignition knob switch as fol-
lows.
OK or NG
OK >> GO TO 3.
NG >> Replace key switch and ignition knob switch.
3. CHECK KEY SWITCH SIGNAL CIRCUIT
1. Disconnect key switch and ignition knob switch connector and BCM connector.
2. Check continuity between key switch and ignition knob switch connector M22 terminal 4 (B/W) and BCM connector M3 termi-
nal 37 (B/W).
3. Check continuity between key switch and ignition knob switch connector M22 terminal 4 (B/W) and ground.
OK or NG
OK >> Key switch (BCM input) circuit is OK.
NG >> Repair or replace harness between key switch and ignition knob switch and BCM. 3 (L/R) – Ground : Battery voltage.
PIIA5093E
Terminals Condition Continuity
34 Key is inserted in ignition key cylinder. Yes
Key is removed from ignition key cylinder. No
PIIA6140E
4 (B/W) – 37 (B/W) : Continuity should exist.
4 (B/W) – Ground : Continuity should not exist.
PIIA5095E

Page 948 of 4731

INTELLIGENT KEY SYSTEM BL-133
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
4. CHECK IGNITION KNOB SWITCH CIRCUIT
1. Disconnect Intelligent Key unit connector.
2. Check continuity between Intelligent Key unit connector M34 terminal 27 (L/W) and key switch and igni- tion knob switch connector M22 terminal 2 (L/W).
3. Check continuity between key switch and ignition knob switch connector terminal 2 (L/W) and ground.
OK or NG
OK >> Replace Intelligent Key unit.
NG >> Repair or replace harness between Intelligent Key unit
and key switch and ignition knob switch.
Check Door SwitchAIS004NF
CHECK DOOR SWITCH (EXCEPT BACK DOOR SWITCH)
1. CHECK DOOR SWITCH INPUT SIGNAL
1. Turn ignition knob LOCK position.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2. 27 (L/W) - 2 (L/W) : Continuity should exist.
2 (L/W) - Ground : Continuity should not exist.
PIIA6743E
Item Connector Terminals
(Wire color) Door
condition Voltage (V)
(Approx.)
(+) (-)
Driver side B14 62 (W)
Ground CLOSE

OPEN Battery voltage

0
Rear LH 63 (P)
Passenger side M3 12 (P/B)
Rear RH 13 (P/L)
PIIA7003E

Page 951 of 4731

BL-136
INTELLIGENT KEY SYSTEM
Revision: 2005 July 2005 FX
5. CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> Check condition of harness and connector.
NG >> Replace BCM.
Check Unlock SensorAIS004NG
1. CHECK UNLOCK SENSOR POWER SUPPLY
Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> Unlock sensor is OK.
NG >> GO TO 2.
2. CHECK UNLOCK SENSOR CIRCUIT
1. Turn ignition knob LOCK position.
2. Disconnect Intelligent Key unit and front door lock assembly (driver side) connector.
3. Check continuity between Intelligent Key unit connector M34 terminal 28 (W/B) and front door lock assembly (driver side) connector D10 terminal 4 (W).
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between Intelligent Key unit and front door lock assembly (driver side).
58 (L) – Ground : Approx. 9V
PIIA6229E
Connector
Terminals (Wire color)
Condition Voltage (V)
(Approx.)
(+) (-)
M34 28 (W/B) Ground Driver side door lock is
locked 5
Driver side door lock is
unlocked 0
PIIA6802E
28 (W/B) – 4 (W) : Continuity should exist.
PIIA6803E

Page 953 of 4731

BL-138
INTELLIGENT KEY SYSTEM
Revision: 2005 July 2005 FX
2. CHECK DOOR REQUEST SWITCH SIGNAL
1. Turn ignition knob LOCK position.
2. Disconnect door request switch connector.
3. Check voltage between door request switch connector D12 (driver door), D42 (passenger door), D113 (back door) terminal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> GO TO 5.
3. CHECK DOOR REQUEST SWITCH OPERATION
Check continuity between door request switch D12 (driver door), D42 (passenger door), D113 (back door) ter-
minals 1 and 2.
OK or NG
OK >> GO TO 4.
NG >> Replace door request switch.
4. CHECK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between door request switch connector D12 (driver side), D42 (passenger side), D113 (back
door) terminal 2 (B) and ground.
OK or NG
OK >> Check harness connection.
NG >> Repair or replace door request switch ground circuit. Driver 1 (SB) - Ground : Approx. 5V
Passenger 1 (GY) - Ground : Approx. 5V
Back door 1 (GY) - Ground : Approx. 5V
PIIA6744E
Terminal Condition Continuity
12 Press door request switch Yes
Return door request switch No
PIIA9930E
2 (B) - Ground : Continuity should exist.
PIIA6746E

Page 962 of 4731

INTELLIGENT KEY SYSTEM BL-147
C
D E
F
G H
J
K L
M A
B
BL
Revision: 2005 July 2005 FX
3. CHECK STOP LAMP SWITCH GROUND CIRCUIT
1. Check continuity between stop lamp switch connector E210 ter- minal 2 (P) and Intelligent Key unit connector M34 terminal 26
(P/L).
2. Check continuity between stop lamp switch connector E210 ter- minal 2 (P) and ground.
OK or NG
OK >> Stop lamp switch is OK.
NG >> Repair or replace harness.
Check Detention SwitchAIS004NN
1. CHECK DETENTION SWITCH INPUT SIGNAL
1. Turn ignition knob LOCK position.
2. Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2. 2 (P) - 26 (P/L) : Continuity should exist.
2 (P) - Ground : Continuity should not exist.
PIIA6801E
Connector Terminal
(Wire color) Condition Voltage (V)
(Approx.)
(+) (-)
M34 39 (R/Y) Ground When selector lever is locked
at the “P” position 0
When selector lever is not
locked at the “P” position Battery voltage
PIIA6805E

Page 965 of 4731

BL-150
INTELLIGENT KEY SYSTEM
Revision: 2005 July 2005 FX
Check Hazard FunctionAIS004NP
1. CHECK HAZARD WARNING LAMP
Does hazard warning lamp flash with hazard switch?
YES or NO
YES >> Hazard warning lamp circuit is OK.
NO >> Check hazard circuit. Refer to LT- 9 1 , "
TURN SIGNAL AND HAZARD WARNING LAMPS" .
Check Horn FunctionAIS004NQ
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-15, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HORN FUNCTION
Does horn sound with horn switch?
YES or NO
YES >> Horn circuit is OK.
NO >> Check horn circuit. Refer to WW-59, "
HORN" .
Check Headlamp FunctionAIS004NR
First perform the “SELF-DIAG RESULTS” in “BCM” with CONSULT-II, then perform the trouble diagnosis of
malfunction system indicated “SELF-DIAG RESULTS” of “BCM”. Refer to BCS-15, "
CAN Communication
Inspection Using CONSULT-II (Self-Diagnosis)" .
1. CHECK HEADLAMP OPERATION
Does headlamp come on when turning lighting switch “ON”?
YES or NO
YES >> Headlamp operation circuit is OK.
NO >> Check headlamp system. Refer to LT- 7 , "
HEADLAMP - XENON TYPE -" .
Check IPDM E/R OperationAIS004NS
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E9 terminal 51 (SB) and ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2. 51 (SB) – Ground : Battery voltage
PIIA6403E

Page:   < prev 1-10 ... 101-110 111-120 121-130 131-140 141-150 151-160 161-170 171-180 181-190 ... 670 next >