vq35de INFINITI FX35 2005 Service Manual
Page 1808 of 4731
DTC P1065 ECM POWER SUPPLY EC-415
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
Diagnostic ProcedureABS006T1
1. CHECK ECM POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check voltage between ECM terminal 121 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connector E211, M41
20A fuse
IPDM E/R harness connector E8
Harness for open or short between ECM and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK INTERMITTENT INCIDENT
Refer to EC-163, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness or connectors.
TER-
MINAL NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
121 R/W Power supply for ECM
(Back-up) [Ignition switch OFF] BATTERY VOLTAGE
(11 - 14V)
Voltage: Battery voltage
MBIB0026E
Page 1809 of 4731
EC-416
[VQ35DE]
DTC P1065 ECM POWER SUPPLY
Revision: 2005 July 2005 FX
4. PERFORM DTC CONFIRMATION PROCEDURE
With CONSULT-II
1. Turn ignition switch ON.
2. Select “SELF DIAG RESULTS” mode with CONSULT-II.
3. Touch “ERASE”.
4. Perform DTC Confirmation Procedure.
See EC-413
.
5. Is the 1st trip DTC P1065 displayed again?
With GST
1. Turn ignition switch ON.
2. Select Service $04 with GST.
3. Perform DTC Confirmation Procedure.
See EC-413
.
4. Is the 1st trip DTC P1065 displayed again?
Ye s o r N o
Yes >> GO TO 5.
No >> INSPECTION END
5. REPLACE ECM
1. Replace ECM.
2. Perform initialization of IVIS(NATS) system and registration of all IVIS(NATS) ignition key IDs. Refer to BL-215, "
ECM Re-Communicating Function" .
3. Perform EC-96, "
VIN Registration" .
4. Perform EC-96, "
Accelerator Pedal Released Position Learning" .
5. Perform EC-96, "
Throttle Valve Closed Position Learning" .
6. Perform EC-97, "
Idle Air Volume Learning" .
>> INSPECTION END
Page 1810 of 4731
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE EC-417
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
D T C P 1111 , P 11 3 6 I V T C O N T R O L SO L E N O I D VA LV EPFP:23796
Component DescriptionABS006T2
Intake valve timing control solenoid valve is activated by ON/OFF
pulse duty (ratio) signals from the ECM.
The intake valve timing control solenoid valve changes the oil
amount and direction of flow through intake valve timing control unit
or stops oil flow.
The longer pulse width advances valve angle.
The shorter pulse width retards valve angle.
When ON and OFF pulse widths become equal, the solenoid valve
stops oil pressure flow to fix the intake valve angle at the control
position.
CONSULT-II Reference Value in Data Monitor ModeABS006T3
Specification data are reference values.
On Board Diagnosis LogicABS006T4
DTC Confirmation ProcedureABS006T5
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and
wait at least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for 5 seconds.
4. If 1st trip DTC is detected, go to EC-421, "
Diagnostic Procedure"
.
WITH GST
Following the procedure “WITH CONSULT-II” above.
PBIB1842E
MONITOR ITEM CONDITION SPECIFICATION
INT/V SOL (B1)
INT/V SOL (B2)
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No-load Idle 0% - 2%
When revving engine up to 2,000 rpm
quickly Approx. 0% - 50%
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P 1111
1111
(Bank 1) Intake valve timing control
solenoid valve circuit An improper voltage is sent to the ECM
through intake valve timing control solenoid
valve.
Harness or connectors
(Intake valve timing control solenoid valve
circuit is open or shorted.)
Intake valve timing control solenoid valve
P1136
11 3 6
(Bank 2)
SEF058Y
Page 1811 of 4731
EC-418
[VQ35DE]
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
Wiring DiagramABS006T6
BANK 1
TBWM0281E
Page 1812 of 4731
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE EC-419
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.) TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
11 B R Intake valve timing control
solenoid valve (bank 1) [Engine is running]
Warm-up condition
Idle speed
BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
When revving engine up to 2,500 rpm
quickly 7 - 12V
PBIB1790E
Page 1813 of 4731
EC-420
[VQ35DE]
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
BANK 2
TBWM0282E
Page 1814 of 4731
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE EC-421
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)
Diagnostic ProcedureABS006T7
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect intake valve timing control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between intake valve timing control solenoid valve terminal 2 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
TER-
MINAL
NO. WIRE
COLOR ITEM CONDITION DATA (DC Voltage)
10 OR Intake valve timing control
solenoid valve (bank 2) [Engine is running]
Warm-up condition
Idle speed
BATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
When revving engine up to 2,500 rpm
quickly 7 - 12V
PBIB1790E
Voltage: Battery voltage
PBIB1562E
PBIB0192E
Page 1815 of 4731
EC-422
[VQ35DE]
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE
Revision: 2005 July 2005 FX
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E19, F49
Harness connectors F10, F211 (Bank 1)
IPDM E/R harness connector E7
Harness for open or short between intake valve timing control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR
OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between ECM terminal 11 (bank 1) or 10 (bank 2) and intake valve timing con- trol solenoid valve terminal 1. Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F211, F10 (Bank 1)
Harness for open and short between ECM and intake valve timing control solenoid valve
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EC-177, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace intake valve timing control solenoid valve.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-163, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
For wiring diagram, refer to EC-302
for CKP sensor (POS), EC-309 and EC-311 for CMP sensor (PHASE).
>> INSPECTION END
Component InspectionABS00E95
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
1. Disconnect intake valve timing control solenoid valve harness connector. Continuity should exist.
Page 1816 of 4731
DTC P1111, P1136 IVT CONTROL SOLENOID VALVE EC-423
[VQ35DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
2. Check resistance between intake valve timing control solenoid
valve as follows.
If NG, replace intake valve timing control solenoid valve.
If OK, go to next step.
3. Remove intake valve timing control solenoid valve.
4. Provide 12V DC between intake valve timing control solenoid valve terminals and then interrupt it. Make sure that the plunger
moves as shown in the figure.
CAUTION:
Do not apply 12V DC continuously for 5 seconds or more.
Doing so may result in damage to the coil in intake valve
timing control solenoid valve.
If NG, replace intake valve timing control solenoid valve.
NOTE:
Always replace O-ring when intake valve timing control
solenoid valve is removed.
Removal and InstallationABS006T9
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EM-64, "TIMING CHAIN" .
Terminal Resistance
1 and 2 7.0 - 7.5 Ω [at 20 °C (68 °F)]
1 or 2 and ground ∞Ω
(Continuity should not exist.)
PBIB0193E
PBIB2275E
Page 1817 of 4731
EC-424
[VQ35DE]
DTC P1121 ELECTRIC THROTTLE CONTROL ACTUATOR
Revision: 2005 July 2005 FX
DTC P1121 ELECTRIC THROTTLE CONTROL ACTUATORPFP:16119
Component DescriptionABS006TA
Electric throttle control actuator consists of throttle control motor, throttle position sensor, etc.
The throttle control motor is operated by the ECM and it opens and closes the throttle valve.
The throttle position sensor detects the throttle valve position, and the opening and closing speed of the throt-
tle valve and feeds the voltage signals to the ECM. The ECM judges the current opening angle of the throttle
valve from these signals and the ECM controls the throttle control motor to make the throttle valve opening
angle properly in response to driving condition.
On Board Diagnosis LogicABS006TB
This self-diagnosis has the one trip detection logic.
FAIL-SAFE MODE
When the malfunction is detected, the ECM enters fail-safe mode and the MIL lights up.
DTC Confirmation ProcedureABS006TC
NOTE:
Perform PROCEDURE FOR MALFUNCTION A AND B first. If the DTC cannot be confirmed, perform
PROCEDURE FOR MALFUNCTION C.
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait
at least 10 seconds before conducting the next test.
PROCEDURE FOR MALFUNCTION A AND B
With CONSULT-II
1. Turn ignition switch ON and wait at least 1 second.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Shift selector lever to D position and wait at least 3 seconds.
4. Shift selector lever to P position.
5. Turn ignition switch OFF, wait at least 10 seconds.
6. Turn ignition switch ON and wait at least 1 second.
7. Shift selector lever to D position, and wait at least 3 seconds.
8. Shift selector lever to P position.
9. Turn ignition switch OFF, wait at least 10 seconds, and then turn ON.
10. If DTC is detected, go to EC-425, "
Diagnostic Procedure" .
With GST
Follow the procedure “With CONSULT-II” above.
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P1121
1121 Electric throttle control
actuator A)
Electric throttle control actuator does not func-
tion properly due to the return spring malfunc-
tion.
Electric throttle control actuator
B) Throttle valve opening angle in fail-safe mode is
not in specified range.
C) ECM detect the throttle valve is stuck open.
Detected items Engine operating condition in fail-safe mode
Malfunction A The ECM controls the electric throttle actuator by regulating the throttle opening around the idle position.
The engine speed will not rise more than 2,000 rpm.
Malfunction B ECM controls the electric throttle control actuator by regulating the throttle opening to 20 degrees or less.
Malfunction C While the vehicle is driving, it slows down gradually by fuel cut. After the vehicle stops, the engine stalls.
The engine can restart in N or P position, and engine speed will not exceed 1,000 rpm or more.
SEF058Y