15. CHECK IGNITION TIMING AGAIN
1. Run engine at idle.
2. Check ignition timing with a timing light. Refer to EC-774
.
OK or NG
OK >> GO TO 19.
NG >> GO TO 16.
16. CHECK TIMING CHAIN INSTALLATION
Check timing chain installation. Refer to EM-200, "
TIMING CHAIN" .
OK or NG
OK >> GO TO 17.
NG >> 1. Repair the timing chain installation.
2. GO TO 4.
17. DETECT MALFUNCTIONING PART
Check the following.
Check camshaft position sensor (PHASE) and circuit. Refer to EC-1043 .
Check crankshaft position sensor (POS) and circuit. Refer to EC-1036 .
OK or NG
OK >> GO TO 18.
NG >> 1. Repair or replace.
2. GO TO 4.
18. CHECK ECM FUNCTION
1. Substitute another known-good ECM to check ECM function. (ECM may be the cause of an incident, but this is a rare case.)
2. Perform initialization of IVIS (NATS) system and registration of all IVIS (NATS) ignition key IDs. Refer to BL-215, "
ECM Re-Communicating Function" .
>> GO TO 4.
19. INSPECTION END
Did you replace ECM, referring this Basic Inspection procedure?
Ye s o r N o
Ye s > > 1 . P e r f o r m EC-786, "VIN Registration" .
2. INSPECTION END
No >> INSPECTION END
12
± 5 ° BTDC (in P or N position)
PBIB1487E

Page 2168 of 4731

BASIC SERVICE PROCEDURE EC-775
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
2. Connect ignition coil No. 1 and spark plug No. 1 with suitable
high-tension wire as shown, and attach timing light clamp to this
wire.
3. Check ignition timing.
Idle Mixture Ratio AdjustmentABS00E4E
PREPARATION
1. Make sure that the following parts are in good order.
–Battery
–Ignition system
–Engine oil and coolant levels
–Fuses
–ECM harness connector
–Va c u u m h o s e s
–Air intake system
(Oil filler cap, oil level gauge, etc.)
–Fuel pressure
–Engine compression
–Throttle valve
–Evaporative emission system
2. On air conditioner equipped models, checks should be carried out while the air conditioner is OFF.
3. On automatic transmission equipped models, when checking idle rpm, ignition timing and mixture ratio, checks should be carried out while selector lever is in N position.
4. When measuring CO percentage, insert probe more than 40 cm (15.7 in) into tail pipe.
PBIB1486E
SEF166Y
PBIB1487E

Page 2170 of 4731

BASIC SERVICE PROCEDURE EC-777
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
DETAILED PROCEDURE
1. INSPECTION START
1. Check service records for any recent repairs that may indicate a related malfunction, or a current need for scheduled maintenance.
2. Open engine hood and check the following:
–Harness connectors for improper connections
–Wiring harness for improper connections, pinches and cut
–Vacuum hoses for splits, kinks and improper connections
–Hoses and ducts for leaks
–Air cleaner clogging
–Gasket
3. Confirm that electrical or mechanical loads are not applied.
–Headlamp switch is OFF.
–Air conditioner switch is OFF.
–Rear window defogger switch is OFF.
–Steering wheel is in the straight-ahead position, etc.
4. Start engine and warm it up until engine coolant temperature indicator points the middle of gauge.
Ensure engine stays below 1,000 rpm.
5. Run engine at about 2,000 rpm for about 2 minutes under no load.
6. Make sure that no DTC is displayed with CONSULT-II or GST.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. REPAIR OR REPLACE
Repair or replace components as necessary according to corresponding Diagnostic Procedure.
>> GO TO 3.
SEF983U
SEF976U
SEF977U

Page 2172 of 4731

BASIC SERVICE PROCEDURE EC-779
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
6. PERFORM IDLE AIR VOLUME LEARNING
Perform EC-787, "
Idle Air Volume Learning" .
Is Idle Air Volume Learning carried out successfully?
Ye s o r N o
Ye s > > G O T O 7 .
No >> 1. Follow the instruction of Idle Air Volume Learning.
2. GO TO 4.
7. CHECK TARGET IDLE SPEED AGAIN
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Read idle speed in “DATA MONITOR” mode with CONSULT-II. Refer to EC-774
.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Check idle speed. Refer to EC-774
.
OK or NG
OK >> GO TO 10.
NG >> GO TO 8.
8. DETECT MALFUNCTIONING PART
Check the Following.
Check camshaft position sensor (PHASE) and circuit. refer to EC-1043 .
Check crankshaft position sensor (POS) and circuit. refer to EC-1036 .
OK or NG
OK >> GO TO 9.
NG >> 1. Repair or replace.
2. GO TO 4.
9. CHECK ECM FUNCTION
1. Substitute another known-good ECM to check ECM function. (ECM may be the cause of an incident, but this is a rare case.)
2. Perform initialization of IVIS (NATS) system and registration of all IVIS (NATS) ignition key IDs. Refer to BL-215, "
ECM Re-Communicating Function" .
>> GO TO 4.
650
± 50 rpm (in P or N position)
650 ± 50 rpm (in P or N position)
SEF174Y

Page 2173 of 4731

EC-780
[VK45DE]
BASIC SERVICE PROCEDURE
Revision: 2005 July 2005 FX
10. CHECK IGNITION TIMING
1. Run engine at idle.
2. Check ignition timing with a timing light. Refer to EC-774
.
OK or NG
OK (With CONSULT-II)>>GO TO 19.
OK (Without CONSULT-II)>>GO TO 20.
NG >> GO TO 11.
11 . PERFORM ACCELERATOR PEDAL RELEASED POSITION LEARNING
1. Stop engine.
2. Perform EC-786, "
Accelerator Pedal Released Position Learning" .
>> GO TO 12.
12. PERFORM THROTTLE VALVE CLOSED POSITION LEARNING
Perform EC-786, "
Throttle Valve Closed Position Learning" .
>> GO TO 13.
13. PERFORM IDLE AIR VOLUME LEARNING
Perform EC-787, "
Idle Air Volume Learning" .
Is Idle Air Volume Learning carried out successfully?
Ye s o r N o
Yes >> GO TO 14.
No >> 1. Follow the instruction of Idle Air Volume Learning.
2. GO TO 4.
14. CHECK TARGET IDLE SPEED AGAIN
With CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Read idle speed in “DATA MONITOR” mode with CONSULT-II. Refer to EC-774
.
Without CONSULT-II
1. Start engine and warm it up to normal operating temperature.
2. Check idle speed. Refer to EC-774
.
OK or NG
OK >> GO TO 15.
NG >> GO TO 17. 12
± 5 ° BTDC (in P or N position)
PBIB1487E
650 ± 50 rpm (in P or N position)
650 ± 50 rpm (in P or N position)
SEF174Y

Page 2174 of 4731

BASIC SERVICE PROCEDURE EC-781
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
15. CHECK IGNITION TIMING AGAIN
1. Run engine at idle.
2. Check ignition timing with a timing light. Refer to EC-774
.
OK or NG
OK (With CONSULT-II)>>GO TO 19.
OK (Without CONSULT-II)>>GO TO 20.
NG >> GO TO 16.
16. CHECK TIMING CHAIN INSTALLATION
Check timing chain installation. Refer to EM-200, "
TIMING CHAIN" .
OK or NG
OK >> GO TO 17.
NG >> 1. Repair the timing chain installation.
2. GO TO 4.
17. DETECT MALFUNCTIONING PART
Check the following.
Check camshaft position sensor (PHASE) and circuit. refer to EC-1043 .
Check crankshaft position sensor (POS) and circuit. refer to EC-1036 .
OK or NG
OK >> GO TO 18.
NG >> 1. Repair or replace.
2. GO TO 4.
18. CHECK ECM FUNCTION
1. Substitute another known-good ECM to check ECM function. (ECM may be the cause of an incident, but this is a rare case.)
2. Perform initialization of IVIS (NATS) system and registration of all IVIS (NATS) ignition key IDs. Refer to BL-215, "
ECM Re-Communicating Function" .
>> GO TO 4.
12
± 5 ° BTDC (in P or N position)
PBIB1487E

Page 2176 of 4731

BASIC SERVICE PROCEDURE EC-783
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
22. CHECK HEATED OXYGEN SENSOR 1 (BANK 2) SIGNAL
Without CONSULT-II
1. Switch the monitored sensor from bank 1 to bank 2. Refer to EC-762, "
How to Switch Monitored Sensor
From Bank 1 to Bank 2 or Vice Versa" .
2. Running engine at 2,000 rpm under no load (The engine is warmed up to normal operating temperature.), check that the MIL comes on more than 5 times during 10 seconds.
OK or NG
OK >> INSPECTION END
NG (MIL does not come on)>>GO TO 24.
NG (MIL comes on less than 5 times)>>GO TO 31.
23. CHECK HEATED OXYGEN SENSOR 1 (BANK 1) HARNESS
1. Turn ignition switch OFF and disconnect battery ground cable.
2. Disconnect ECM harness connector.
3. Disconnect heated oxygen sensor 1 (bank 1) harness connector.
4. Check harness continuity between ECM terminal 16 and heated oxygen sensor 1 (bank 1) terminal 1. Refer to Wiring Diagram, EC-937, "
BANK 1" .
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 25.
NG >> 1. Repair or replace harness between ECM and heated oxygen sensor 1 (bank 1).
2. GO TO 4.
24. CHECK HEATED OXYGEN SENSOR 1 (BANK 2) HARNESS
1. Turn ignition switch OFF and disconnect battery ground cable.
2. Disconnect ECM harness connector.
3. Disconnect heated oxygen sensor 1 (bank 2) harness connector.
4. Check harness continuity between ECM terminal 35 and heated oxygen sensor 1 (bank 2) terminal 1. Refer to Wiring Diagram, EC-939, "
BANK 2" .
5. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 25.
NG >> 1. Repair or replace harness between ECM and heated oxygen sensor 1 (bank 2).
2. GO TO 4.
25. PERFORM ACCELERATOR PEDAL RELEASED POSITION LEARNING
1. Reconnect ECM harness connector and heated oxygen sensor 1 harness connector.
2. Perform EC-786, "
Accelerator Pedal Released Position Learning" .
>> GO TO 26.
26. PERFORM THROTTLE VALVE CLOSED POSITION LEARNING
Perform EC-786, "
Throttle Valve Closed Position Learning" .
>> GO TO 27.
Continuity should exist.
Continuity should exist.

Page 2177 of 4731

EC-784
[VK45DE]
BASIC SERVICE PROCEDURE
Revision: 2005 July 2005 FX
27. PERFORM IDLE AIR VOLUME LEARNING
Refer to EC-787, "
Idle Air Volume Learning" .
Is Idle Air Volume Learning carried out successfully?
Ye s o r N o
Yes (With CONSULT-II)>>GO TO 28.
Yes (Without CONSULT-II)>>GO TO 29.
No >> 1. Follow the instruction of Idle Air Volume Learning.
2. GO TO 4.
28. CHECK CO%
With CONSULT-II
1. Start engine and warm it up until engine coolant temperature indicator points the middle of gauge.
2. Turn ignition switch OFF, wait at least 10 seconds and then turn ON.
3. Select “ENG COOLANT TEMP” in “ACTIVE TEST” mode.
4. Set “ENG COOLANT TEMP” to 5 °C (41 °F) by touching “DOWN”
and “Qd”.
5. Start engine and rev it (2,000 to 3,000 rpm) two or three times under no load, then run engine at idle speed.
6. Check CO%.
OK or NG
OK >> GO TO 31.
NG >> GO TO 30.
29. CHECK CO%
Without CONSULT-II
1. Start engine and warm it up until engine coolant temperature indicator points to the middle of gauge.
2. Turn ignition switch OFF.
3. Disconnect engine coolant temperature sensor harness connector.
4. Connect a resistor (4.4 k Ω) between terminals of engine coolant
temperature sensor harness connector.
5. Start engine and rev it (2,000 to 3,000 rpm) two or three times under no load, then run engine at idle speed.
6. Check CO%.
7. After checking CO%, turn ignition switch OFF, disconnect the resistor from the terminals of engine coolant temperature sensor
harness connector, and then connect engine coolant tempera-
ture sensor harness connector to engine coolant temperature
sensor.
OK or NG
OK >> GO TO 31.
NG >> GO TO 30.
30. RECONNECT HEATED OXYGEN SENSOR 1 HARNESS CONNECTOR
1. Turn ignition switch OFF.
2. Reconnect heated oxygen sensor 1 harness connector.
>> GO TO 34.
Idle CO: 0.7
− 9.9% and engine runs smoothly.
SEF172Y
Idle CO: 0.7 − 9.9% and engine runs smoothly.
SEF982UA

Page 2178 of 4731

BASIC SERVICE PROCEDURE EC-785
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
31. REPLACE HEATED OXYGEN SENSOR 1
1. Stop engine.
2. Replace heated oxygen sensor 1 on the malfunctioning bank.
With CONSULT-II>>GO TO 32.
Without CONSULT-II>>GO TO 33.
32. CHECK HEATED OXYGEN SENSOR 1 (BANK 1) / (BANK 2) SIGNAL
With CONSULT-II
1. Start engine and warm it up until engine coolant temperature indicator points the middle of gauge.
2. See “HO2S1 MNTR (B1)/(B2)” in “DATA MONITOR” mode.
3. Running engine at 2,000 rpm under no load (The engine is warmed up to normal operating temperature.), check that the
monitor fluctuates between LEAN and RICH more than 5 times
during 10 seconds.
OK or NG
OK >> GO TO 4.
NG >> GO TO 34.
33. CHECK HEATED OXYGEN SENSOR 1 (BANK 1) / (BANK 2) SIGNAL
Without CONSULT-II
1. Set ECM to Self Diagnostic Test Mode II (Heated oxygen sensor 1 monitor). Refer to EC-762, "
HOW TO
SWITCH DIAGNOSTIC TEST MODE" .
2. Switch the monitored sensor to the malfunctioning bank. Refer to EC-762, "
How to Switch Monitored Sen-
sor From Bank 1 to Bank 2 or Vice Versa" .
3. Running engine at 2,000 rpm under no load (The engine is warmed up to normal operating temperature.), check that the MIL comes on more than 5 times during 10 seconds.
OK or NG
OK >> GO TO 4.
NG >> GO TO 34.
34. DETECT MALFUNCTIONING PART
Check the following.
Check fuel pressure regulator and repair or replace if necessary. Refer to EC-789 .
Check mass air flow sensor and its circuit, and repair or replace if necessary. Refer to EC-902 .
Check injector and its circuit, and repair or replace if necessary. Refer to EC-1351 .
Check engine coolant temperature sensor and its circuit, and repair or replace if necessary. Refer to EC-
914 and EC-927 .
OK or NG
OK >> GO TO 36.
NG >> 1. Repair or replace.
2. GO TO 35.
1 time: RICH
→ LEAN → RICH
2 times: RICH → LEAN → RICH → LEAN → RICH
SEF449Y

Page 2180 of 4731

BASIC SERVICE PROCEDURE EC-787
[VK45DE]
C
D E
F
G H
I
J
K L
M A
EC
Revision: 2005 July 2005 FX
OPERATION PROCEDURE
1. Make sure that accelerator pedal is fully released.
2. Turn ignition switch ON.
3. Turn ignition switch OFF and wait at least 10 seconds. Make sure that throttle valve moves during above 10 seconds by confirming the operating sound.
Idle Air Volume LearningABS00E4I
DESCRIPTION
Idle Air Volume Learning is an operation to learn the idle air volume that keeps each engine within the specific
range. It must be performed under any of the following conditions:
Each time electric throttle control actuator or ECM is replaced.
Idle speed or ignition timing is out of specification.
PREPARATION
Before performing Idle Air Volume Learning, make sure that all of the following conditions are satisfied.
Learning will be cancelled if any of the following conditions are missed for even a moment.
Battery voltage: More than 12.9V (At idle)
Engine coolant temperature: 70 - 99 °C (158 - 210 °F)
PNP switch: ON
Electric load switch: OFF
(Air conditioner, headlamp, rear window defogger)
On vehicles equipped with daytime light systems, if the parking brake is applied before the engine
is started the headlamp will not be illuminated.
Steering wheel: Neutral (Straight-ahead position)
Vehicle speed: Stopped
Transmission: Warmed-up
For models with CONSULT-II, drive vehicle until “ATF TEMP SE 1” in “DATA MONITOR” mode of “A/T”
system indicates less than 0.9V.
For models without CONSULT-II, drive vehicle for 10 minutes.
OPERATION PROCEDURE
With CONSULT-II
1. Perform EC-786, "Accelerator Pedal Released Position Learning" .
2. Perform EC-786, "
Throttle Valve Closed Position Learning" .
3. Start engine and warm it up to normal operating temperature.
4. Check that all items listed under the topic PREPARATION (previously mentioned) are in good order.
5. Select “IDLE AIR VOL LEARN” in “WORK SUPPORT” mode.
SEF217Z

Page:   < prev 1-10 ... 881-890 891-900 901-910 911-920 921-930 931-940 941-950 951-960 961-970 ... 1790 next >