key INFINITI FX35 2006 Service Manual
Page 3721 of 4462
INTERIOR ROOM LAMP LT-159
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
through grounds M35, M45 and M85
to map lamp terminal 1.
And power is supplied
from BCM terminal 41
to map lamp terminal 3.
When interior room lamp switch is ON, ground supplied (without DVD player)
through grounds M35, M45 and M85
to interior room lamp terminal 3.
And power is supplied (without DVD player)
from BCM terminal 41
to interior room lamp terminal 2.
When personal lamp LH or RH switch is ON, ground supplied
through grounds M35, M45 and M85
to personal lamp LH or RH terminal 3.
And power is supplied
from BCM terminal 41
to personal lamp LH or RH terminal 2.
When vanity mirror lamp (driver side or passenger side) is ON, ground is supplied
through grounds M35, M45 and M85
to vanity mirror lamp (driver side or passenger side) terminal 2.
And power is supplied
from BCM terminal 41
to vanity mirror lamp (driver side or passenger side) terminal 1.
When luggage room lamp (back door side) is ON, ground is supplied
through grounds B15 and B45
to luggage room lamp (back door side) terminal 3.
And power is supplied
from BCM terminal 41
to luggage room lamp (back door side) terminals 2.
ROOM LAMP TIMER OPERATION
Without Intelligent Key System
When the interior room lamp and map lamp switch is in DOOR position, and when all conditions below are
met, BCM performs timer control (maximum 30 seconds) for interior room lamp and map lamp ON/OFF.
In addition, when spot turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
to 15A fuse [No. 22, located infuse block (J/B)]
through key switch terminal 2.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Ground is supplied
from BCM terminal 22
to power window main switch (door lock and unlock switch) terminal 14.
At the time that driver door are opened, BCM detects that driver door is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns interior room lamp and map lamp ON
for 30 seconds.
Key is in ignition key cylinder (key switch ON),
Power is supplied
through key switch terminal 1
to BCM terminal 37.
Page 3722 of 4462
LT-160
INTERIOR ROOM LAMP
Revision: 2006 December 2006 FX35/FX45
When the key is removed from key switch (key switch OFF), power supply to BCM terminal 37 is terminated.
BCM detects that key has been removed, determines that interior room lamp and map lamp timer conditions
are met, and turns interior room lamp and map lamp ON for 30 seconds.
When driver door opens → closes, and key is not inserted in key switch (key switch OFF), BCM terminal 62
changes between 0V (door open) → 12V (door closed). BCM determines that conditions for interior room lamp
and map lamp operation are met and turns interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Driver door is locked [when locked keyfob or power window main switch (door lock and unlock switch),
door key cylinder switch].
Driver door is opened (driver door switch turns ON).
Ignition switch ON.
With Intelligent Key System
When the interior room lamp and map lamp switch is in DOOR position, and when all conditions below are
met, BCM performs timer control (maximum 30 second) for interior room lamp and map lamp ON/OFF.
In addition, when spot turns ON or OFF there is gradual brightening or dimming over 1 second.
Power is supplied
to 15A fuse [No. 22, located in fuse and fuse block (J/B)]
through key switch and ignition knob switch terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
And not turned ignition knob switch, power will not be supplied to Intelligent Key unit.
Ground is supplied
from BCM terminal 22
to power window main switch (door lock and unlock switch) terminal 14.
At the time that driver door are opened, BCM detects that driver door is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns interior room lamp and map lamp ON
for 30 seconds.
Key is in ignition key cylinder (key switch ON), or turned ignition knob switch,
Power is supplied
through key switch and ignition knob switch terminal 4
to BCM terminal 37,
through key switch and ignition knob switch terminal 2
to intelligent key unit terminal 27.
When the key is removed from key switch (key switch OFF), power supply to BCM terminal 37 is terminated.
And turned ignition knob switch, power supply to Intelligent Key unit is terminated. BCM detects that key has
been removed, determines that interior room lamp and map lamp timer conditions are met, and turns interior
room lamp and map lamp ON for 30 seconds.
When driver door opens → closes, and key is not inserted in key switch (or not turned ignition knob switch),
BCM terminal 62 changes between 0V (door open) → 12V (door closed). BCM determines that conditions for
interior room lamp and map lamp operation are met and turns interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Driver door is locked [when locked keyfob, power window main switch (door lock and unlock switch) or
door key cylinder switch].
Driver door is opened (driver door switch terns ON).
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned out even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Luggage room lamp
Vanity mirror lamp
Map lamp
Interior room lamp
Personal lamp
After lamps turn OFF by battery saver system, lamps illuminate again when
Page 3723 of 4462
INTERIOR ROOM LAMP LT-161
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
signal from keyfob, or power window main switch (door lock and unlock switch) or key cylinder is locked or
unlocked,
door is opened or closed,
key is removed from ignition key cylinder or inserted in ignition key cylinder, or turned ignition knob switch.
Interior lamp battery saver control period can be changed by the function setting of CONSULT-II.
Page 3734 of 4462
LT-172
INTERIOR ROOM LAMP
Revision: 2006 December 2006 FX35/FX45
Terminals and Reference Values for BCMNKS002YQ
Te r m i n a l No. Wire
color Signal name Measuring condition
Reference value
Ignition
switch Operation or condition
1PU Ignition keyhole illumi-
nation signal OFF Door is locked. (SW OFF) Battery voltage
Door is unlocked. (SW ON) Approx. 0 V
12 P/B Front door switch AS
signal OFF
Front door switch
AS ON (open) Approx. 0 V
OFF (closed) Battery voltage
13 P/L Rear door switch RH
signal OFF
Rear door switch
RH ON (open) Approx. 0 V
OFF (closed) Battery voltage
22 OR Power window switch
serial link ——
37 B/W Key-in detection
switch signal OFF Vehicle key is removed. Approx. 0 V
Vehicle key is inserted. Battery voltage
38 W/L Ignition power supply ON — Battery voltage
39 L CAN − H— — —
40 P CAN − L— — —
41 R/B Battery saver output
signal OFF
30 minutes after ignition switch is turned to
OFF Approx. 0 V
ON — Battery voltage
42 L/R Battery power supply OFF — Battery voltage
47 Y/R Step lamp signal OFF Any door is open (ON) Approx. 0 V
All doors are closed (OFF) Battery voltage
48 PU/W Interior room lamp,
map lamp, front door
inside handle and rear
door inside handle illu-
mination output signal OFF
Interior door
switch:
DOOR position Any
door
switch ON (open) Approx. 0 V
OFF (closed) Battery voltage
49 B Ground ON — Approx. 0 V
52 B Ground ON — Approx. 0 V
55 G Battery power supply OFF — Battery voltage
58 L Back door switch sig-
nal (Auto close motor) OFF Back door switch ON (open) Approx. 0 V
OFF (closed) Battery voltage
62 W Front door switch DR
signal OFF
Front door switch
DR ON (open) Approx. 0 V
OFF (closed) Battery voltage
63 P Rear door switch LH
signal OFF
Rear door switch
LH ON (open) Approx. 0 V
OFF (closed) Battery voltage
PIIA2344J
Page 3736 of 4462
LT-174
INTERIOR ROOM LAMP
Revision: 2006 December 2006 FX35/FX45
CONSULT-II Functions (BCM)NKS002YT
CONSULT-II can display each diagnostic item using the diagnostic test mode shown following.
CONSULT-II BASIC OPERATION
Refer to GI-38, "CONSULT-II Start Procedure" .
WORK SUPPORT (INT LAMP)
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen.
3. Touch “SET I/L D − UNLCK INTCON” on “SELECT WORK ITEM” screen.
4. Touch “START”.
5. Touch “CHANGE SETT”.
6. The setting will be changed and “CUSTOMIZING COMPLETED ” will be displayed.
7. Touch “END”.
Display Item List
Reference between “MODE” and “TIME” for “TURN ON/OFF”
DATA MONITOR (INT LAMP)
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch either “ALL SIGNALS” or “SELECTION FROM MENU” on “SELECT MONITOR ITEM” screen.
4. When “SELECTION FROM MENU” is selected, touch items to be monitored. When “ALL SIGNALS” is selected, all the items will be monitored.
5. Touch “START”.
6. Touch “RECORD” while monitoring, then the status of the monitored item can be recorded. To stop recording, touch “STOP”.
BCM diagnosis part Diagnosis mode Description
INT LAMP WORK SUPPORT Changes setting for each function.
DATA MONITOR Displays BCM input data in real time. ACTIVE TEST Operation of electrical loads can be checked by sending driving signal to them.
BATTERY SAVER WORK SUPPORT Changes the setting for each function.
DATA MONITOR Displays BCM input data in real time. ACTIVE TEST Operation of electrical loads can be checked by sending driving signal to them.
Item Description CONSULT-II
SET I/L D −UNLCK INTCON The 30 seconds glowing function interior room lamps and ignition keyhole illu-
mination can be selected when driver door is released (unlocked). ON/OFF
ROOM LAMP ON TIME SET The time in order to escalate illumination can be adjusted when interior room
lamps and ignition keyhole illumination is turned on. MODE 1 – 7
ROOM LAMP OFF TIME SET The time in order to diminish illumination can be adjusted when interior room
lamps and ignition keyhole illumination is turned off. MODE 1 – 7
MODE 1 2 3 4 5 6 7
Time (sec.) 0.5 1 2 3 4 5 0
All signals Monitors all the signals.
Selection from menu Selects items and monitors them.
Page 3737 of 4462
INTERIOR ROOM LAMP LT-175
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
Display Item List
NOTE:
Vehicle with intelligent key system display this item.
ACTIVE TEST (INT LAMP)
Operation Procedure
1. Touch “INT LAMP” on “SELECT TEST ITEM” screen.
2. Touch “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch item to be tested and check operation of the selected item.
4. During the operation check, touching “OFF” deactivates the operation.
Display Item List
NOTE:
This item is displayed, but cannot be tested. Monitor item Contents
IGN ON SW “ON/OFF” Displays “IGN position (ON)/OFF, ACC position (OFF)” judged from the ignition switch signal.
KEY ON SW “ON/OFF” Displays “Key inserted (ON)/key removed (OFF)” status judged from the key switch signal.
DOOR SW - DR “ON/OFF” Displays status of the driver door as judged from the driver door switch signal. (Door is open:
ON/Door is closed: OFF)
DOOR SW - AS “ON/OFF” Displays status of the passenger door as judged from passenger door switch signal. (Door
open (ON)/Door closed (OFF))
DOOR SW - RR “ON/OFF” Displays status of rear door as judged from the rear door switch (RH) signal. (Door is open:
ON/Door is closed: OFF)
DOOR SW - RL “ON/OFF” Displays status of rear door as judged from the rear door switch (LH) signal. (Door is open:
ON/Door is closed: OFF)
BACK DOOR SW “ON/OFF” Displays status of the back door as judged from back door switch signal. (Door open (ON)/
Door closed (OFF))
KEY CYL LK - SW “ON/OFF” Displays “Door locked (ON) status, determined from key cylinder lock switch in driver door.
KEY CYL UN - SW “ON/OFF” Displays “Door unlocked (OFF) status, determined from key cylinder lock switch in driver
door.
CDL LOCK SW “ON/OFF” Displays “Door locked (ON)/Door unlocked (OFF) status, determined from locking detection
switch in driver door.
CDL UNLOCK SW “ON/OFF” Displays “Door unlocked (OFF)” status, determined from locking detection switch in passen-
ger door.
I − KEY LOCK
NOTE“ON/OFF” Displays “Locked (ON)/Other (OFF)” status, determined from lock signal.
I − KEY UNLOCK
NOTE“ON/OFF” Displays “Unlocked (ON)/Other (OFF)” status, determined from unlock signal.
Test item Description
INT LAMP Interior room lamp can be operated by any ON-OFF operations.
IGN ILLUM Ignition key hole illumination can be operated by ON-OFF operation.
STEP LAMP TEST All step lamp can be operated by ON-OFF operation.
LUGGAGE LAMP TEST
NOTE—
Page 3738 of 4462
LT-176
INTERIOR ROOM LAMP
Revision: 2006 December 2006 FX35/FX45
WORK SUPPORT (BATTERY SAVER)
Operation Procedure
1. Touch “BATTERY SAVER” on “SELECT TEST ITEM” screen.
2. Touch “WORK SUPPORT” on “SELECT DIAG MODE” screen.
3. Touch “ROOM LAMP BAT SAV SET” on “SELECT WORK ITEM” screen.
4. Touch “START”.
5. Touch “CHANGE SETT”.
6. The setting will be changed and “CUSTOMIZING COMPLETED ” will be displayed.
7. Touch “END”.
Display Item List
DATA MONITOR (BATTERY SAVER)
Operation Procedure
1. Touch “BATTERY SAVER” on “SELECT TEST ITEM” screen.
2. Touch “DATA MONITOR” on “SELECT DIAG MODE” screen.
3. Touch either “ALL SIGNALS” or “SELECTION FROM MENU” on “SELECT MONITOR ITEM” screen.
4. When “SELECTION FROM MENU” is selected, touch items to be monitored. When “ALL SIGNALS” is selected, all items will be monitored.
5. Touch “START”.
6. Touch “RECORD” while monitoring, then the status of monitored item can be recorded. To stop recording, touch “STOP”.
Display Item List
Item Description CONSULT-II
ROOM LAMP TIME SET Interior room lamp battery saver timer setting can be changed. MODE 1: 30min
MODE 2: 60min
ALL SIGNALS Monitors all the signals.
SELECTION FROM MENU Selects items and monitor them.
Monitor item Contents
IGN ON SW “ON/OFF” Displays “IGN position (ON)/OFF, ACC position (OFF)” judged from the ignition switch signal.
KEY ON SW “ON/OFF” Displays “Key inserted (ON)/key removed (OFF)” status judged from the key switch signal.
DOOR SW - DR “ON/OFF” Displays status of the driver door as judged from the driver door switch signal. (Door is open:
ON/Door is closed: OFF)
DOOR SW - AS “ON/OFF” Displays status of the passenger door as judged from passenger door switch signal. (Door
open (ON)/Door closed (OFF))
DOOR SW - RR “ON/OFF” Displays status of rear door as judged from the rear door switch (RH) signal. (Door is open:
ON/Door is closed: OFF)
DOOR SW - RL “ON/OFF” Displays status of rear door as judged from the rear door switch (LH) signal. (Door is open:
ON/Door is closed: OFF)
BACK DOOR SW “ON/OFF” Displays status of the back door as judged from back door switch signal. (Door open (ON)/
Door closed (OFF))
KEY CYL LK - SW “ON/OFF” Displays “Door locked (ON) status, determined from key cylinder lock switch in driver door.
KEY CYL UN - SW “ON/OFF” Displays “Door unlocked (OFF) status, determined from key cylinder lock switch in driver
door.
CDL LOCK SW “ON/OFF” Displays “Door locked (ON)/Door unlocked (OFF) status, determined from locking detection
switch in driver door.
CDL UNLOCK SW “ON/OFF” Displays “Door unlocked (OFF)” status, determined from locking detection switch in passen-
ger door.
I − KEY LOCK
NOTE“ON/OFF” Displays “Locked (ON)/Other (OFF)” status, determined from lock signal.
I − KEY UNLOCK
NOTE“ON/OFF” Displays “Unlocked (ON)/Other (OFF)” status, determined from unlock signal.
Page 3739 of 4462
INTERIOR ROOM LAMP LT-177
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
NOTE:
Vehicle with intelligent key system display this item.
ACTIVE TEST (BATTERY SAVER)
Operation Procedure
1. Touch “BATTERY SAVER” on “SELECT TEST ITEM” screen.
2. Touch “ACTIVE TEST” on “SELECT DIAG MODE” screen.
3. Touch item to be tested and check operation of the selected item.
4. During the operation check, touching “OFF” deactivates the operation.
Display Item List
Interior Room Lamp Control Does Not OperateNKS002YU
1. CHECK EACH SWITCH
Select “BCM” on CONSULT-II. With “INT LAMP” data monitor to
make sure switches listed in display item list turn ON-OFF linked
with switch operation. Refer to LT- 1 7 5 , "
Display Item List" for
switches and their functions.
OK or NG
OK >> GO TO 2.
NG >> Inspect malfunctioning switch system.
2. ACTIVE TEST
1. Select “BCM” on CONSULT-II. Select “INT LAMP” active test.
2. When interior room lamp switch is in DOOR position, use active test to make sure interior room lamp operates.
OK or NG
OK >> Replace BCM. Refer to BCS-15, "Removal and Installa-
tion of BCM" .
NG >> GO TO 3.
3. CHECK INTERIOR ROOM LAMP INPUT
1. Turn ignition switch OFF.
2. Check voltage between interior room lamp harness connector R53 terminal 1 and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 4.
Test item Description
BATTERY SAVER Interior room lamp can be operated by ON −OFF operations.
PKIB3532E
PKIA7641E
1 – Ground : Battery voltage.
PKIA5249E
Page 3744 of 4462
LT-182
INTERIOR ROOM LAMP
Revision: 2006 December 2006 FX35/FX45
4. CHECK PERSONAL LAMP CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and personal lamp harness connector.
OK or NG
OK >> Replace BCM if personal lamp does not work after set- ting the connector again. Refer to BCS-15, "
Removal
and Installation of BCM" .
NG >> Repair harness or connector.
Ignition Key Hole Illumination Control Does Not OperateNKS002YX
1. CHECK EACH SWITCH
Select “BCM” on CONSULT-II. With “INT LAMP” data monitor to
make sure switches listed in display item list turn ON-OFF linked
with switch operation. Refer to LT- 1 7 5 , "
Display Item List" for
switches and their functions.
OK or NG
OK >> GO TO 2.
NG >> Inspect malfunctioning switch system.
2. ACTIVE TEST
1. Select “BCM” on CONSULT-II. Select “INT LAMP”.
2. Select “IGN ILLUM” active test to make sure lamp operates.
OK or NG
OK >> Replace BCM. Refer to BCS-15, "Removal and Installa-
tion of BCM" .
NG >> GO TO 3.
3. CHECK IGNITION KEY HOLE ILLUMINATION INPUT
1. Turn ignition switch OFF.
2. Check voltage between ignition key hole illumination harness connector M24 terminal 1 and ground.
OK or NG
OK >> GO TO 4.
NG >> GO TO 6.
BCM Personal lamp Continuity
Connector Terminal Connector Terminal
M4 41 RH R55
2Yes
LH R54
PKIB3517E
PKIB3532E
Ignition key hole illumination should operate.
PKIA7642E
1 – Ground : Battery voltage.
PKIA5260E
Page 3745 of 4462
INTERIOR ROOM LAMP LT-183
C
D E
F
G H
I
J
L
M A
B
LT
Revision: 2006 December 2006 FX35/FX45
4. CHECK IGNITION KEY HOLE ILLUMINATION BULB
1. Disconnect ignition key hole illumination connector.
2. Check continuity between ignition key hole illumination terminals 1 and 2.
OK or NG
OK >> GO TO 5.
NG >> Replace ignition key hole illumination. Refer to . LT- 1 8 5 ,
"IGNITION KEY HOLE ILLUMINATION (without
inteligent key)"LT- 1 8 5 , "IGNITION KEY HOLE ILLUMI-
NATION (with inteligent key)"
5. CHECK IGNITION KEY HOLE ILLUMINATION CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector M3 terminal 1 and ignition key hole illumination harness connector M24 ter-
minal 2.
OK or NG
OK >> Replace BCM if ignition key hole illumination does not work after setting the connector again. Refer to BCS-15,
"Removal and Installation of BCM" .
NG >> Repair harness or connector.
6. CHECK IGNITION KEY HOLE ILLUMINATION CIRCUIT
1. Disconnect BCM connector and ignition key hole illumination connector.
2. Check continuity between BCM harness connector M4 terminal 41 and ignition key hole illumination harness connector M24 ter-
minal 1.
OK or NG
OK >> Replace BCM if ignition key hole illumination does not work after setting the connector again. Refer to BCS-15,
"Removal and Installation of BCM" .
NG >> Repair harness or connector. 1 – 2 : Continuity should exist.
PKIA7789E
1 – 2 : Continuity should exist.
PKIA7643E
41 – 1 : Continuity should exist.
PKIB3520E