SYSTEM DESCRIPTION
Unified meter and A/C amp. controls compressor operation by ambient temperature, intake air temperature
and signal from ECM.
Low Temperature Protection Control
Unified meter and A/C amp. will turn the compressor ON or OFF as determined by a signal detected by ambi-
ent sensor and intake sensor.
When ambient temperature is higher than −2 °C (28 °F), the compres-
sor turns ON. The compressor turns OFF when ambient temperature
is lower than −5 °C (23 °F).
When intake air temperature is higher than 1 °C (34 °F), the compres-
sor turns ON. The compressor turns OFF when intake air tempera-
ture is lower than −5°C (23 °F).
DIAGNOSIS PROCEDURE FOR MAGNET CLUTCH
SYMPTOM: Magnet clutch does not engage when A/C switch is ON.
RHA094GB
SJIA0267E
SJIA1608E

Page 530 of 4366

ATC-84
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
1. CHECK AMBIENT SENSOR AND INTAKE SENSOR CIRCUIT
Check ambient sensor and intake sensor. Refer to AT C - 5 3 , "
FUNCTION CONFIRMATION PROCEDURE" ,
see No. 9 and 11.
OK or NG
OK >> GO TO 2.
NG >>
Malfunctioning ambient sensor: Refer to ATC-103, "Ambient Sensor Circuit" .
Malfunctioning intake sensor: Refer to AT C - 11 2 , "Intake Sensor Circuit" .
2. PERFORM AUTO ACTIVE TEST
Refer to PG-21, "
Auto Active Test" .
Does the magnet clutch operate?
YES >>WITH CONSULT-II: GO TO 5
WITHOUT CONSULT-II: GO TO 6.
NO >> Check 10A fuse (No. 79, located in IPDM E/R). Refer to PG-25, "
IPDM E/R Terminal Arrange-
ment" , and GO TO 3.
3. CHECK CIRCUIT CONTINUITY BETWEEN IPDM E/R AND COMPRESSOR
1. Turn ignition switch OFF.
2. Disconnect IPDM E/R connector and compressor connector.
3. Check continuity between IPDM E/R harness connector E8 ter- minal 33 and compressor harness connector F2 terminal 1.
OK or NG
OK >> GO TO 4.
NG >> Repair harness or connector.
4. CHECK MAGNET CLUTCH CIRCUIT
Check for operation sound when applying battery voltage direct cur-
rent to terminal.
OK or NG
OK >> 1. Replace IPDM E/R. 2. Go to self-diagnosis procedure AT C - 5 3 , "
FUNCTION
CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-4. Confirm that magnet clutch opera-
tion normal.
NG >> 1. Replace magnet clutch. 2. Go to self-diagnosis procedure AT C - 5 3 , "
FUNCTION
CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-4. Confirm that magnet clutch operation normal.
33 – 1 : Continuity should exist.
RJIA2004E
RJIA2005E

Page 533 of 4366

TROUBLE DIAGNOSIS ATC-87
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
8. CHECK REFRIGERANT PRESSURE SENSOR
WITH CONSULT-II
1. Start the engine.
2. Check voltage of refrigerant pressure sensor. Refer to EC-132, "
CONSULT-II Reference Value in Data
Monitor" (VQ35DE) or EC-796, "CONSULT-II Reference Value in Data Monitor" (VK45DE).
WITHOUT CONSULT-II
1. Start the engine.
2. Check voltage between ECM harness connector F101 terminal 70 and ground.
OK or NG
OK >>WITH CONSULT-II: GO TO 9.
WITHOUT CONSULT-II: GO TO 10.
NG >> Refer to EC-663, "
REFRIGERANT PRESSURE SENSOR" (VQ35DE) or EC-1345, "REFRIGER-
ANT PRESSURE SENSOR" (VK45DE).
9. CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal. Refer to AT C - 4 0 , "
CONSULT-II Function
(BCM)" .
OK or NG
OK >> GO TO 12.
NG >> GO TO 10.
10. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect BCM connector and unified meter and A/C amp. connector.
3. Check continuity between BCM harness connector M3 terminal 28 and unified meter and A/C amp. harness connector M57 ter-
minal 57.
OK or NG
OK >> GO TO 11.
NG >> Repair harness or connector.
Terminals
Condition Voltage
(+)
( − )
ECM
connec-
tor Terminal
No.
F101 70 Ground A/C switch: ON
(Blower motor operates.) Approx. 1.0 - 4.0
V
PBIB1188E
FAN SW ON : FAN ON SIG ON
FAN SW OFF : FAN ON SIG OFF
R J I A 1111 E
28 – 57 : Continuity should exist.
RJIA2009E

Page 535 of 4366

TROUBLE DIAGNOSIS ATC-89
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
COMPONENT INSPECTION
Refrigerant Pressure Sensor
The refrigerant pressure sensor is attached to the condenser.
Make sure that the A/C refrigerant pressure and the sensor output
voltage are within the specified range as shown in the A/C operating
condition figure. Refer to EC-663, "
REFRIGERANT PRESSURE
SENSOR" (VQ35DE) or EC-1345, "REFRIGERANT PRESSURE
SENSOR" (VK45DE).
RJIA2011E
RJIA2954E

Page 542 of 4366

ATC-96
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
High-pressure Side is Too Low and Low-pressure Side is Too High
Both High- and Low-pressure Sides are Too Low
Gauge indication Refrigerant cycle Probable cause Corrective action
High-pressure side is too low and
low-pressure side is too high. High- and low-pressure sides
become equal soon after com-
pressor operation stops. Compressor pressure opera-
tion is improper.

Damaged inside compressor
packings. Replace compressor.
No temperature difference
between high- and low-pres-
sure sides. Compressor pressure opera-
tion is improper.

Damaged inside compressor
packings. Replace compressor.
AC356A
Gauge indication Refrigerant cycle Probable cause Corrective action
Both high- and low-pressure sides
are too low.
There is a big temperature
difference between liquid
tank outlet and inlet. Outlet
temperature is extremely
low.
Liquid tank inlet and expan-
sion valve are frosted. Liquid tank inside is slightly
clogged.
Replace liquid tank.
Check lubricant for contami-
nation.
Temperature of expansion
valve inlet is extremely low
as compared with areas
near liquid tank.
Expansion valve inlet is
frosted.
Temperature difference
occurs somewhere in high-
pressure side. High-pressure pipe located
between liquid tank and
expansion valve is clogged.
Check and repair malfunc-
tioning parts.
Check lubricant for contami-
nation.
Expansion valve and liquid
tank are warm or slightly cool
when touched. Low refrigerant charge.

Leaking fittings or compo-
nents. Check refrigerant for leaks.
Refer to ATC-156, "
Checking
for Refrigerant Leaks" .
There is a big temperature dif-
ference between expansion
valve inlet and outlet while the
valve itself is frosted. Expansion valve closes a little
compared with the specifica-
tion.

1. Improper expansion valve adjustment.
2. Malfunctioning expansion valve.
3. Outlet and inlet may be clogged.
Remove foreign particles by
using compressed air.
Replace expansion valve.
Check lubricant for contami-
nation.
An area of the low-pressure
pipe is colder than areas near
the evaporator outlet. Low-pressure pipe is clogged
or crushed.
Check and repair malfunc-
tioning parts.
Check lubricant for contami-
nation.
Air flow volume is not enough
or is too low. Evaporator is frozen.
Check intake sensor circuit.
Refer to AT C - 11 2 , "
Intake
Sensor Circuit" .
Replace compressor.
Repair evaporator fins.
Replace evaporator.
Refer to AT C - 7 7 , "Blower
Motor Circuit" .
AC353A

Page 545 of 4366

TROUBLE DIAGNOSIS ATC-99
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
Insufficient HeatingNJS000EB
SYMPTOM: Insufficient heating
INSPECTION FLOW
*1ATC-60, "Operational Check"*2ATC-71, "Air Mix Door Motor Circuit"*3AT C - 5 3 , "FUNCTION CONFIRMA-
TION PROCEDURE", see No. 4 to
6.
*4 ATC-53, "
FUNCTION CONFIRMA-
TION PROCEDURE", see No. 13. *5
ATC-64, "
LAN System Circuit"*6AT C - 7 7 , "Blower Motor Circuit"
*7 EC-209, "DTC P0117, P0118 ECT
SENSOR" (VQ35DE) or EC-880,
"DTC P0117, P0118 ECT SEN-
SOR" (VK45DE) *8
CO-11, "
Changing Engine Coolant"
(VQ35DE) or CO-38, "
Changing
Engine Coolant" (VK45DE) *9
CO-15, "
Checking Radiator Cap"
(VQ35DE) or CO-43, "
Checking
Radiator Cap" (VK45DE)
SJIA1593E

Page 549 of 4366

TROUBLE DIAGNOSIS ATC-103
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
Ambient Sensor CircuitNJS000EF
COMPONENT DESCRIPTION
Ambient Sensor
The ambient sensor is attached on the hood lock stay. It detects
ambient temperature and converts it into a resistance value which is
then input into the unified meter and A/C amp.
AMBIENT TEMPERATURE INPUT PROCESS
The unified meter and A/C amp. includes a processing circuit for the ambient sensor input. However, when the
temperature detected by the ambient sensor increases quickly, the processing circuit retards the unified meter
and A/C amp. function. It only allows the unified meter and A/C amp. to recognize an ambient temperature
increase of 0.33 °C (0.6 °F) per 100 seconds.
As an example, consider stopping for a few minutes after high speed driving. Although the actual ambient tem-
perature has not changed, the temperature detected by the ambient sensor will increase. This is because the
heat from the engine compartment can radiate to the front grille area, location of the ambient sensor.
DIAGNOSIS PROCEDURE FOR AMBIENT SENSOR
SYMPTOM: Ambient sensor circuit is open or shorted. (21 or −21 is
indicated on unified meter and A/C amp. as a result of performing
self-diagnosis STEP-2.)
1. CHECK VOLTAGE BETWEEN AMBIENT SENSOR AND GROUND
1. Disconnect ambient sensor connector.
2. Turn ignition switch ON.
3. Check voltage between ambient sensor harness connector E34 terminal 1 and ground.
OK or NG
OK >> GO TO 2.
NG >> GO TO 4.
RJIA2016E
RJIA1461E
1 – Ground : Approx. 5 V
RJIA2017E

Page 550 of 4366

ATC-104
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
2. CHECK CIRCUIT CONTINUITY BETWEEN AMBIENT SENSOR AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect unified meter and A/C amp. connector.
3. Check continuity between ambient sensor harness connector E34 terminal 2 and unified meter and A/C amp. harness connec-
tor M57 terminal 49.
OK or NG
OK >> GO TO 3.
NG >> Repair harness or connector.
3. CHECK AMBIENT SENSOR
Refer to ATC-105, "
Ambient Sensor" .
OK or NG
OK >> 1. Replace unified meter and A/C amp. 2. Go to self-diagnosis AT C - 5 3 , "
FUNCTION CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-2. Confirm that code No. 20 is displayed.
NG >> 1. Replace ambient sensor. 2. Go to self-diagnosis AT C - 5 3 , "
FUNCTION CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-2. Confirm that code No. 20 is displayed.
4. CHECK CIRCUIT CONTINUITY BETWEEN AMBIENT SENSOR AND UNIFIED METER AND A/C AMP.
1. Turn ignition switch OFF.
2. Disconnect unified meter and A/C amp. connector.
3. Check continuity between ambient sensor harness connector E34 terminal 1 and unified meter and A/C amp. harness connec-
tor M57 terminal 39.
4. Check continuity between ambient sensor harness connector E34 terminal 1 and ground.
OK or NG
OK >> 1. Replace unified meter and A/C amp. 2. Go to self-diagnosis AT C - 5 3 , "
FUNCTION CONFIRMATION PROCEDURE" and perform self-
diagnosis STEP-2. Confirm that code No. 20 is displayed.
NG >> Repair harness or connector. 2 – 49 : Continuity should exist.
RJIA2018E
1 – 39 : Continuity should exist.
1 – Ground : Continuity should not exist.
RJIA2019E

Page 551 of 4366

TROUBLE DIAGNOSIS ATC-105
C
D E
F
G H
I
K L
M A
B
AT C
Revision: 2006 July 2007 FX35/FX45
COMPONENT INSPECTION
Ambient Sensor
After disconnecting ambient sensor connector E34, measure resis-
tance between terminals 1 and 2 at sensor side. Refer to the table
below.
If NG, replace ambient sensor.
Temperature °C ( °F) Resistance k Ω
− 15 (5) 12.73
− 10 (14) 9.92
− 5 (23) 7.80
0 (32) 6.19
5 (41) 4.95
10 (50) 3.99
15 (59) 3.24
20 (68) 2.65
25 (77) 2.19
30 (86) 1.81
35 (95) 1.51
40 (104) 1.27 45 (113) 1.07
RJIA2020E

Page 552 of 4366

ATC-106
TROUBLE DIAGNOSIS
Revision: 2006 July 2007 FX35/FX45
In-vehicle Sensor CircuitNJS000EG
COMPONENT DESCRIPTION
In-vehicle Sensor
The in-vehicle sensor is located on instrument driver lower panel. It
converts variations in temperature of compartment air drawn from
the aspirator into a resistance value. It is then input into the unified
meter and A/C amp.
Aspirator
The aspirator is located on driver’s side of heater & cooling unit
assembly. It produces vacuum pressure due to air discharged from
the heater & cooling unit assembly, continuously taking compartment
air in the aspirator.