trunk INFINITI M35 2007 Factory Owner's Guide

Page 1015 of 4647

BL-82
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
AUTO RELOCK TIMERAuto door lock timer mode can select the following with this mode.1 min
5 min
OFF: Non-operation
PANIC ALARM DELAYPanic alarm button's pressing time on Intelligent Key remote control button can be selected from
the following with this mode. The operation mode will be changed when “CHANGE SETT” on
CONSULT-II screen is touched.
0.5 sec
1.5 sec
OFF: Non-operation
TRUNK/GLASS HATCH OPENBuzzer reminder function mode by trunk opener request switch can be changed to operate (ON)
or not operate (OFF) with this mode. The operation mode will be changed when “CHANGE
SETT” on CONSULT-II screen is touched.
TRUNK OPEN DELAYTrunk button's pressing time on Intelligent Key button can be selected from the following with this
mode. The operation mode will be changed when “CHANGE SETT” on CONSULT-II screen is
touched.
0.5 sec
1.5 sec
OFF: Non-operation
P/W DOWN DELAYUnlock button's pressing time on Intelligent Key button can be selected from the following with
this mode. The operation mode will be changed when “CHANGE SETT” on CONSULT-II screen
is touched.
3 sec
5 sec
OFF: Non-operation
ENGINE START BY I-KEYEngine start function mode can be changed to operate (ON) or not operate (OFF) with this mode.
The operation mode will be changed when “CHANGE SETT” on CONSULT-II screen is touched.
LOCK/UNLOCK BY I-KEYDoor lock/unlock function by door request switch (driver side, passenger side and trunk) mode
can be changed to operate (ON) or not operate (OFF) with this mode. The operation mode will be
changed when “CHANGE SETT” on CONSULT-II screen is touched. Monitor item Description

Page 1016 of 4647

INTELLIGENT KEY SYSTEM
BL-83
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
ACTIVE TEST
Test item Description
DOOR LOCK/UNLOCKThis test is able to check door lock/unlock operation.
The all door lock actuators are locked when “LOCK” on CONSULT-II screen is touched.
The all door lock actuators are unlocked when “ALL UNLK” on CONSULT-II screen is touched.
The door lock actuator (driver side) is unlocked when “DR UNLK” on CONSULT-II screen is
touched.
The door lock actuator (passenger side) is unlocked when “AS UNLK” on CONSULT- II screen
is touched.
The trunk lid opener actuator is open when “TRUNK OPEN” on CONSULT- II screen is
touched.
ANTENNAThis test is able to check Intelligent Key antenna operation.
When the following conditions are met, hazard warning lamps flash.
Inside key antenna (Instrument center) detects Intelligent Key, when “ROOM ANT1” on CON-
SULT-II screen is touched.
Inside key antenna (Center console) detects Intelligent Key, when “ROOM ANT2” on CON-
SULT-II screen is touched.
Inside key antenna (rear seat) detects Intelligent Key, when “ROOM ANT3” on CONSULT-II
screen is touched.
Inside key antenna (Trunk room) detects Intelligent Key, when “LAG ANT1” on CONSULT-II
screen is touched.
Outside key antenna (Driver side) detects Intelligent Key, when “DRIVER ANT” on CONSULT-II
screen is touched.
Outside key antenna (Passenger side) detects Intelligent Key, when “ASSIST ANT” on CON-
SULT-II screen is touched.
Outside key antenna (Trunk room) detects Intelligent Key, when “BD/TR ANT” on CONSULT-II
screen is touched.
OUTSIDE BUZZERThis test is able to check Intelligent Key warning buzzer operation.
Intelligent Key warning buzzer sounds when “ON” on CONSULT-II screen is touched.
INSIDE BUZZERThis test is able to check warning chime into combination meter operation.
Take away warning chime sounds when “TAKE OUT” on CONSULT-II screen is touched.
Key warning chime sounds when “KEY WARN” on CONSULT-II screen is touched.
P position warning chime sounds when “P RNG WARN” on CONSULT-II screen is touched.
ACC warning chime sounds when “ACC WARN” on CONSULT-II screen is touched.
INDICATORThis test is able to check warning lamp operation.
“KEY” Warning lamp illuminates when “KEY IND ON” on CONSULT-II screen is touched.
“KEY” Warning lamp flashes when “KEY IND FSH” on CONSULT-II screen is touched.
LCDThis test is able to check meter display information
Engine start information displays when “BRAKE/P” on CONSULT-II screen is touched.
Engine start information displays when “BRAKE/P/ON” on CONSULT-II screen is touched.
Key ID warning displays when “KEY ID NG” on CONSULT-II screen is touched.
Steering lock information displays when “STLCK RELES” on CONSULT-II screen is touched.
P position warning displays when “P RNG IND” on CONSULT-II screen is touched.
Intelligent Key insert information displays when “INSERT KEY” on CONSULT-II screen is
touched.
Intelligent Key low battery warning displays when “KEY BAT LOW” on CONSULT-II screen is
touched.
Take away through window warning displays when “TK AWAY WDW” on CONSULT-II screen is
touched.
Take away warning display when “TAKE AWAY” on CONSULT-II screen is touched.
OFF position warning display when “IGN OFF WARN” on CONSULT-II screen is touched.
P RANGEThis test is able to check A/T device power supply
A/T device power is supplied when “ON” on CONSULT-II screen is touched.

Page 1019 of 4647

BL-86
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
TRUNK OPEN FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check “Trouble Diagnosis Procedure”. Refer to BL-
77, "Trouble Diagnosis Procedure" .
Make sure that vehicle is under the condition shown in “Conditions of vehicle” before starting diagnosis,
and check each symptom.
If the following “symptoms” are detected, check systems shown in the “Diagnosis/service procedure” col-
umn in this order.
Conditions of Vehicle (Operating Conditions)
Intelligent Key is out of key slot.
All doors are closed.
Auto lock function does not operate prop-
erly.1. Check “AUTO RELOCK TIMER” setting in “WORK SUPPORT”.BL-812. Check door switch.BL-94
3. Check key slot.BL-92
4. Replace BCM.BCS-15
Key reminder function does not operate.1.Check “ANTI KEY LOCK IN FUNCTION” setting in “WORK SUP-
PORT”.BL-81
2. Check door switch.BL-94
3. Check inside key antenna.BL-110
4. Check unlock sensor.BL-103
5. Check Intelligent Key battery inspection.BL-124
6. Replace Intelligent Key unit.BL-123
Panic alarm function does not operate.1. Check “PANIC ALARM DELAY” setting in “WORK SUPPORT”.BL-81
2. Check theft warning operation.BL-217
3. Check Intelligent Key battery inspection.BL-124
4. Check key slot.BL-92
5. Replace Intelligent Key unit.BL-123
Symptom Diagnosis/service procedureReference
page
Symptom Diagnosis/service procedure Reference page
Trunk open function does not operate by trunk
opener request switch.1. Check trunk opener request switch.BL-101

2. Check trunk lid opener cancel switch.BL-119
3. Check outside key antenna (trunk room).BL-108
4. Replace Intelligent Key unit.BL-123
Trunk open function does not operate by Intelli-
gent Key.1.Check “TRUNK OPEN DELAY” setting in “WORK
SUPPORT”.BL-812. Check trunk lid opener system.BL-207
3. Check trunk room lamp switch.BL-97
4. Check Intelligent Key battery inspection.BL-124
5. Replace Intelligent Key unit.BL-123
Key reminder function does not operate.1. Check door switch.BL-94
2. Check trunk room lamp switch.BL-97
3. Check inside key antenna (trunk room).BL-110
4. Check trunk lid opener system.BL-207
5. Replace Intelligent Key unit.BL-123

Page 1020 of 4647

INTELLIGENT KEY SYSTEM
BL-87
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
HAZARD AND BUZZER REMINDER FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check “Trouble Diagnosis Procedure”. Refer to BL-
77, "Trouble Diagnosis Procedure" .
If the following “symptoms” are detected, check systems shown in the “Diagnosis/service procedure” col-
umn in this order.
Conditions of Vehicle (Operating Conditions)
“LOCK/UNLOCK BY I-KEY” is ON when setting on CONSULT-II.
“ANSWER BACK FUNCTION” is ON when setting on CONSULT-II.
Ignition switch is in OFF position.
All doors are closed.
Intelligent Key is out of key slot.
HAZARD AND HORN REMINDER FUNCTION MALFUNCTION
NOTE:
Before performing the diagnosis in the following table, check “Trouble Diagnosis Procedure”. Refer to BL-
77, "Trouble Diagnosis Procedure" .
Make sure that vehicle is under the condition shown in “Conditions of vehicle” before starting diagnosis,
and check each symptom.
If the following “symptoms” are detected, check systems shown in the “Diagnosis/service procedure” col-
umn in this order.
Conditions of Vehicle (Operating Conditions)
“ANSWER BACK FUNCTION” is ON when setting on CONSULT-II.
Ignition switch is in OFF position.
All doors are closed.
Symptom Diagnosis/service procedure Reference page
Hazard reminder does not operate by
request switch.
(Horn reminder operate.)1.Check “HAZARD ANSWER BACK” setting in “WORK
SUPPORT”.BL-81
2. Check hazard function with hazard switch.LT-212
3. Replace Intelligent Key unit.BL-123
Buzzer reminder does not operate by request
switch.
(Hazard reminder operate.)1.Check “ANSWER BACK WITH I-KEY LOCK” or
“ANSWER BACK WITH I-KEY UNLOCK” setting in
“WORK SUPPORT”.BL-81
2. Check Intelligent Key warning buzzer.BL-105
3. Replace Intelligent Key unit.BL-123
Buzzer reminder does not operate by trunk
opener request switch.1.Check “TRUNK/GLASS HATCH OPEN” setting in “WORK
SUPPORT”.BL-812. Check Intelligent Key warning buzzer.BL-105
3. Check trunk opener lid system.BL-207
4. Replace Intelligent Key unitBL-123
Symptom Diagnosis/service procedure Reference page
Hazard reminder does not operate by Intelli-
gent Key button.
(Horn reminder operate.)1.Check “HAZARD ANSWER BACK” setting in “WORK
SUPPORT”.BL-81
2. Check hazard function with hazard switch.LT-212
3. Replace Intelligent KeyBL-123
Horn reminder does not operate by Intelligent
Key button (door lock/unlock button).
(Hazard reminder operate.)1.Check “HORN WITH KEYLESS LOCK” setting in “WORK
SUPPORT”.BL-81
2. Check horn function.BL-122
3. Replace Intelligent Key unitBL-123

Page 1030 of 4647

INTELLIGENT KEY SYSTEM
BL-97
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
Check Trunk Room Lamp SwitchNIS001XP
1. CHECK TRUNK ROOM LAMP SWITCH INPUT SIGNAL
With CONSULT-II
Check (“TRUNK SW”) in “DATA MONITOR” mode with CONSULT-II.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> Trunk room lamp switch circuit is OK.
NG >> GO TO 2.
2. CHECK TRUNK ROOM LAMP SWITCH
1. Turn ignition switch OFF.
2. Disconnect trunk lid lock assembly connector.
3. Check trunk room lamp switch.
OK or NG
OK >> GO TO 3.
NG >> Replace trunk room lamp switch.
Monitor item Condition
TRUNK SWOPEN : ON
CLOSE : OFF
PIIB1362E
Terminals
Trunk
conditionVoltage (V)
(Approx.) (+)
(–)
BCM connector Terminal
M3 57 GroundOPEN 0
CLOSE Battery voltage
PIIB6326E
Terminal
Trunk condition Continuity
Trunk room lamp switch
12OPEN Yes
CLOSE No
PIIB8995E

Page 1031 of 4647

BL-98
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
3. CHECK TRUNK ROOM LAMP SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM connector and trunk lid lock assembly connector.
3. Check continuity between BCM connector and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness between BCM and trunk room lamp switch.
4. CHECK TRUNK ROOM LAMP SWITCH GROUND CIRCUIT
Check continuity between trunk lid lock assembly connector and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace trunk room lamp switch ground circuit.
5. CHECK BCM OUTPUT SIGNAL
1. Connect BCM connector.
2. Check voltage between BCM connector and ground.
OK or NG
OK >> Check the condition of harness and connector.
NG >> Replace BCM.
AB
Continuity
BCM connector TerminalTrunk lid lock
assembly
connectorTerminal
M3 57 T106 1 Yes
A
GroundContinuity
BCM connector Terminal
M3 57 No
PIIB8997E
Trunk lid lock
assembly
connectorTerminal
GroundContinuity
T106 2 Yes
PIIB8996E
Terminals
Voltage (V)
(Approx.) (+)
(–)
BCM connector Terminal
M3 57 Ground Battery voltage
PIIB6326E

Page 1034 of 4647

INTELLIGENT KEY SYSTEM
BL-101
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
5. CHECK INTELLIGENT KEY UNIT OUTPUT SIGNAL
1. Connect Intelligent Key unit connector.
2. Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> Check the condition of harness and connector.
NG >> Replace Intelligent Key unit.
Check Trunk Opener Request SwitchNIS001XR
1. CHECK TRUNK OPENER REQUEST SWITCH
With CONSULT-II
Check trunk opener request switch (“BD/TR REQ SW”) in “DATA MONITOR” mode.
Without CONSULT-II
1. Turn ignition switch OFF.
2. Check voltage between Intelligent Key unit connector and ground.
OK or NG
OK >> Trunk opener request switch is OK.
NG >> GO TO 2.
Terminals
Voltage (V)
(Approx.) (+)
(–)
Intelligent Key unit
connectorTerminal
M322
Ground 5
22
PIIB6330E
Monitor item Condition
BD/TR REQ SWTrunk opener request switch is pressed: ON
Trunk opener request switch is released: OFF
PIIB4266E
Terminals
Trunk lid
opener
request switch
conditionVoltage (V)
(Approx.) (+)
(–)
Intelligent Key
unit connectorTerminal
M33 61 GroundPressed 0
Released 5
PIIB8990E

Page 1035 of 4647

BL-102
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
2. CHECK TRUNK OPENER REQUEST SWITCH CIRCUIT
1. Disconnect Intelligent Key unit and trunk opener request switch connector.
2. Check continuity between Intelligent Key unit connector and trunk opener request switch connector.
3. Check continuity between Intelligent Key unit connector and
ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness between Intelligent Key unit and trunk opener request switch.
3. CHECK TRUNK OPENER REQUEST SWITCH OPERATION
Check trunk opener request switch.
OK or NG
OK >> GO TO 4.
NG >> Replace trunk opener request switch.
4. CHECK TRUNK OPENER REQUEST SWITCH GROUND CIRCUIT
Check continuity between trunk opener request switch connector and ground.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace trunk opener request switch ground
circuit.
AB
Continuity
Intelligent Key
unit connectorTerminal Trunk request
switch connectorTerminal
M33 61 T107 1 Yes
A
GroundContinuity
Intelligent Key unit
connectorTe r m i n a l
M33 61 No
PIIB8991E
Terminal
Trunk opener request
switch conditionContinuity
Trunk opener request switch
12Pressed Yes
Released No
PIIB6336E
Trunk opener request
switch connectorTerminal
GroundContinuity
T107 2 Yes
PIIB6337E

Page 1041 of 4647

BL-108
INTELLIGENT KEY SYSTEM
Revision: 2007 April2007 M35/M45
Check Outside Key Antenna (Trunk Room)NIS001XV
1. CHECK OUTSIDE KEY ANTENNA FUNCTION
With CONSULT-II
1. Check the operation with (“ANTENNA”) in the ACTIVE TEST.
2. Touch “BD/TR ANT” on screen.
3. Carry the Intelligent Key into the antenna detection area.
Do the hazard lamps flash?
Yes >> Outside key antenna (trunk room) is OK.
No >> GO TO 2.
2. CHECK OUTSIDE KEY ANTENNA INPUT SIGNAL 1
1. Turn ignition switch OFF.
2. Check signal between Intelligent Key unit connector and ground with oscilloscope.
OK or NG
OK >> Check the condition of harness and connector.
NG >> GO TO 3.
Test item Corresponding antenna
BD/TR ANT Outside key antenna trunk room
PIIB6345E
Te r m i n a l s
ConditionSignal
(Reference value.) (+)
(–) Intelligent
Key unit
connectorTerminal
M32 17 GroundTrunk
request
switch is
pushed
PIIB8925E
SIIA1910J

Page 1042 of 4647

INTELLIGENT KEY SYSTEM
BL-109
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: 2007 April2007 M35/M45
3. CHECK OUTSIDE KEY ANTENNA CIRCUIT
1. Disconnect Intelligent Key unit and outside key antenna (trunk room) connector.
2. Check continuity between Intelligent Key unit connector and outside key antenna (trunk room) connector.
3. Check continuity between Intelligent Key unit connector and
ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness between Intelligent Key unit and outside key antenna (trunk room).
4. CHECK OUTSIDE KEY ANTENNA INPUT SIGNAL 2
1. Replace outside key antenna. (New antenna or other antenna)
2. Connect Intelligent Key unit and outside key antenna (trunk room) connector.
3. Check signal between Intelligent Key unit connector and ground with oscilloscope.
OK or NG
OK >> Replace malfunction front outside handle.
NG >> Replace Intelligent Key unit.
AB
Continuity
Intelligent Key
unit connectorTerminalOutside key
antenna (trunk
room) connectorTerminal
M3217
B1211
Ye s
18 2
A
GroundContinuity
Intelligent Key unit
connectorTerminal
M3217
No
18
PIIB8926E
Te r m i n a l s
ConditionSignal
(Reference value.) (+)
(–) Intelligent
Key unit
connectorTerminal
M32 17 GroundTrunk
request
switch is
pushed
PIIB8925E
SIIA1910J

Page:   < prev 1-10 11-20 21-30 31-40 41-50 51-60 61-70 71-80 ... 130 next >