DTC P0011, P0021 IVT CONTROL
EC-169
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
6. CHECK TIMING CHAIN INSTALLATION
Check service records for any recent repairs that may cause timing chain misaligned.
Ye s o r N o
Yes >> Check timing chain installation. Refer to EM-66, "TIMING CHAIN" .
No >> GO TO 7.
7. CHECK LUBRICATION CIRCUIT
Refer to EM-93, "
Inspection of Camshaft Sprocket (INT) Oil Groove" .
OK or NG
OK >> GO TO 8.
NG >> Clean lubrication line.
8. CHECK INTERMITTENT INCIDENT
Refer to EC-153, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
For Wiring Diagram, refer to EC-366
for CKP sensor (POS) and EC-373 for CMP sensor (PHASE).
>>INSPECTION END
Component InspectionNBS004TY
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
1. Disconnect intake valve timing control solenoid valve harness connector.
2. Check resistance between intake valve timing control solenoid
valve terminals as follows.
If NG, replace intake valve timing control solenoid valve.
If OK, go to next step.
3. Remove intake valve timing control solenoid valve.
4. Provide 12V DC between intake valve timing control solenoid
valve terminals and then interrupt it. Make sure that the plunger
moves as shown in the figure.
CAUTION:
Do not apply 12V DC continuously for 5 seconds or more.
Doing so may result in damage to the coil in intake valve
timing control solenoid valve.
If NG, replace intake valve timing control solenoid valve.
NOTE:
Always replace O-ring when intake valve timing control
solenoid valve is removed.
Removal and InstallationNBS004TZ
INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EM-85, "CAMSHAFT" . Are there any service records that may cause timing chain misaligned?
Terminals Resistance
1 and 2 7.0 - 7.5Ω [at 20°C (68°F)]
1 or 2 and ground∞Ω
(Continuity should not exist)
PBIB0193E
PBIB2275E
Page 1699 of 4647
EC-170
[VQ35DE]
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATER
Revision: 2007 April2007 M35/M45
DTC P0031, P0032, P0051, P0052 A/F SENSOR 1 HEATERPFP:22693
DescriptionNBS004U0
SYSTEM DESCRIPTION
The ECM performs ON/OFF duty control of the A/F sensor 1 heater corresponding to the engine operating
condition to keep the temperature of A/F sensor 1 element at the specified range.
CONSULT-II Reference Value in Data Monitor ModeNBS004U1
Specification data are reference values.
On Board Diagnosis LogicNBS004U2
DTC Confirmation ProcedureNBS004U3
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and wait at
least 10 seconds before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm that battery voltage is between 10.5V and 16V at
idle.
WITH CONSULT-II
1. Turn ignition switch ON and select “DATA MONITOR” mode with
CONSULT-II.
2. Start engine and let it idle for at least 10 seconds.
3. If 1st trip DTC is detected, go to EC-174, "
Diagnostic Procedure"
.
WITH GST
Follow the procedure “WITH CONSULT-II” above.
Sensor Input Signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)Engine speed
Air fuel ratio (A/F) sensor 1
heater controlAir fuel ratio (A/F) sensor 1
heater
Mass air flow sensor Amount of intake air
MONITOR ITEM CONDITION SPECIFICATION
A/F S1 HTR (B1)
A/F S1 HTR (B2)
Engine: After warming up, idle the engine 0 - 100%
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0031
0031
(Bank 1)Air fuel ratio (A/F) sensor
1 heater control circuit
lowThe current amperage in the A/F sensor 1 heater
circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM
through the A/F sensor 1 heater.)
Harness or connectors
(The A/F sensor 1 heater circuit is
open or shorted.)
A/F sensor 1 heater P0051
0051
(Bank 2)
P0032
0032
(Bank 1)Air fuel ratio (A/F) sensor
1 heater control circuit
highThe current amperage in the A/F sensor 1 heater
circuit is out of the normal range.
(An excessively high voltage signal is sent to ECM
through the A/F sensor 1 heater.)
Harness or connectors
(The A/F sensor 1 heater circuit is
shorted.)
A/F sensor 1 heater P0052
0052
(Bank 2)
SEF058Y
Page 1706 of 4647
DTC P0037, P0038, P0057, P0058 HO2S2 HEATER
EC-177
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0037, P0038, P0057, P0058 HO2S2 HEATERPFP:226A0
DescriptionNBS004U8
SYSTEM DESCRIPTION
The ECM performs ON/OFF control of the heated oxygen sensor 2 heater corresponding to the engine speed,
amount of intake air and engine coolant temperature.
OPERATION
CONSULT-II Reference Value in Data Monitor ModeNBS004U9
Specification data are reference values.
On Board Diagnosis LogicNBS004UA
Sensor Input signal to ECM ECM function Actuator
Camshaft position sensor (PHASE)
Crankshaft position sensor (POS)Engine speed
Heated oxygen sensor 2
heater controlHeated oxygen sensor 2 heater
Engine coolant temperature sensor Engine coolant temperature
Mass air flow sensor Amount of intake air
Engine speed rpm Heated oxygen sensor 2 heater
Above 3,600OFF
Below 3,600 rpm after the following conditions are met.
Engine: After warming up
Keeping the engine speed between 3,500 and 4,000 rpm for 1
minute and at idle for 1 minute under no loadON
MONITOR ITEM CONDITION SPECIFICATION
HO2S2 HTR (B1)
HO2S2 HTR (B2)
Engine speed: Below 3,600 rpm after the following conditions are met.
–Engine: After warming up
–Keeping the engine speed between 3,500 and 4,000 rpm for 1 minute and at
idle for 1 minute under no loadON
Engine speed: Above 3,600 rpm OFF
DTC No.Trouble diagnosis
nameDTC detecting condition Possible cause
P0037
0037
(Bank 1)Heated oxygen
sensor 2 heater
control circuit lowThe current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively low voltage signal is sent to ECM
through the heated oxygen sensor 2 heater.)
Harness or connectors
(The heated oxygen sensor 2 heater circuit is
open or shorted.)
Heated oxygen sensor 2 heater P0057
0057
(Bank 2)
P0038
0038
(Bank 1)Heated oxygen
sensor 2 heater
control circuit highThe current amperage in the heated oxygen sen-
sor 2 heater circuit is out of the normal range.
(An excessively high voltage signal is sent to
ECM through the heated oxygen sensor 2
heater.)
Harness or connectors
(The heated oxygen sensor 2 heater circuit is
shorted.)
Heated oxygen sensor 2 heater P0058
0058
(Bank 2)
Page 1714 of 4647
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-185
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
DTC P0075, P0081 IVT CONTROL SOLENOID VALVEPFP:23796
Component DescriptionNBS004UG
Intake valve timing control solenoid valve is activated by ON/OFF
pulse duty (ratio) signals from the ECM.
The intake valve timing control solenoid valve changes the oil
amount and direction of flow through intake valve timing control unit
or stops oil flow.
The longer pulse width advances valve angle.
The shorter pulse width retards valve angle.
When ON and OFF pulse widths become equal, the solenoid valve
stops oil pressure flow to fix the intake valve angle at the control
position.
CONSULT-II Reference Value in Data Monitor ModeNBS004UH
Specification data are reference values.
On Board Diagnosis LogicNBS004UI
DTC Confirmation ProcedureNBS004UJ
NOTE:
If DTC Confirmation Procedure has been previously conducted, always turn ignition switch OFF and
wait at least 10 seconds before conducting the next test.
WITH CONSULT-II
1. Turn ignition switch ON.
2. Select “DATA MONITOR” mode with CONSULT-II.
3. Start engine and let it idle for 5 seconds.
4. If 1st trip DTC is detected, go to EC-190, "
Diagnostic Procedure"
.
WITH GST
Following the procedure “WITH CONSULT-II” above.
PBIB1842E
MONITOR ITEM CONDITION SPECIFICATION
INT/V SOL (B1)
INT/V SOL (B2)
Engine: After warming up
Selector lever: P or N
Air conditioner switch: OFF
No loadIdle 0% - 2%
When revving engine up to 2,000 rpm
quicklyApprox. 25% - 50%
DTC No. Trouble diagnosis name DTC detecting condition Possible cause
P0075
0075
(Bank 1)
Intake valve timing control
solenoid valve circuitAn improper voltage is sent to the ECM
through intake valve timing control solenoid
valve.
Harness or connectors
(Intake valve timing control solenoid valve
circuit is open or shorted.)
Intake valve timing control solenoid valve P0081
0081
(Bank 2)
SEF058Y
Page 1715 of 4647
EC-186
[VQ35DE]
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2007 April2007 M35/M45
Wiring DiagramNBS004UK
BANK 1
TBWT0971E
Page 1716 of 4647
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-187
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
11 W / RIntake valve timing control
solenoid valve (bank 1)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
When revving engine up to 2,000rpm
quickly7 - 12V
111 S BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB1790E
Page 1717 of 4647
EC-188
[VQ35DE]
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2007 April2007 M35/M45
BANK 2
TBWT0972E
Page 1718 of 4647
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-189
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
Specification data are reference values and are measured between each terminal and ground.
Pulse signal is measured by CONSULT-II.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECM's transistor. Use a ground other than ECM terminals, such as the ground.
: Average voltage for pulse signal (Actual pulse signal can be confirmed by oscilloscope.)TER-
MINAL
NO.WIRE
COLORITEM CONDITION DATA (DC Voltage)
10 W/GIntake valve timing control
solenoid valve (bank 2)[Engine is running]
Warm-up condition
Idle speedBATTERY VOLTAGE
(11 - 14V)
[Engine is running]
Warm-up condition
When revving engine up to 2,000rpm
quickly7 - 12V
111 S BECM relay
(Self shut-off)[Engine is running]
[Ignition switch: OFF]
For a few seconds after turning ignition
switch OFF0 - 1.5V
[Ignition switch: OFF]
More than a few seconds after turning igni-
tion switch OFFBATTERY VOLTAGE
(11 - 14V)
11 9
120R
RPower supply for ECM[Ignition switch: ON]BATTERY VOLTAGE
(11 - 14V)
PBIB1790E
Page 1719 of 4647
EC-190
[VQ35DE]
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
Revision: 2007 April2007 M35/M45
Diagnostic ProcedureNBS004UL
1. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect intake valve timing control solenoid valve harness connector.
3. Turn ignition switch ON.
4. Check voltage between intake valve timing control solenoid
valve terminal 2 and ground with CONSULT-II or tester.
OK or NG
OK >> GO TO 3.
NG >> GO TO 2.
2. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors E12, F3
Harness connectors E18, F201 (bank 1)
Harness for open or short between intake valve timing control solenoid valve and IPDM E/R
>> Repair open circuit or short to ground or short to power in harness or connectors.
3. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR
OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect ECM harness connector.
3. Check harness continuity between the following;
ECM terminal 11 and intake valve timing control solenoid valve (bank 1) terminal 1 or
ECM terminal 10 and intake valve timing control solenoid valve (bank 2) terminal 1.
Refer to Wiring Diagram.
4. Also check harness for short to ground and short to power.
OK or NG
OK >> GO TO 5.
NG >> GO TO 4.Voltage: Battery voltage
PBIB1562E
PBIB0192E
Continuity should exist.
Page 1720 of 4647
DTC P0075, P0081 IVT CONTROL SOLENOID VALVE
EC-191
[VQ35DE]
C
D
E
F
G
H
I
J
K
L
MA
EC
Revision: 2007 April2007 M35/M45
4. DETECT MALFUNCTIONING PART
Check the following.
Harness connectors F201, F18 (bank 1)
Harness for open or short between intake valve timing control solenoid valve and ECM
>> Repair open circuit or short to ground or short to power in harness or connectors.
5. CHECK INTAKE VALVE TIMING CONTROL SOLENOID VALVE
Refer to EC-192, "
Component Inspection" .
OK or NG
OK >> GO TO 6.
NG >> Replace malfunctioning intake valve timing control solenoid valve.
6. CHECK INTERMITTENT INCIDENT
Refer to EC-153, "
TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT" .
>>INSPECTION END