1-3 Warning and Indicator Lamp Information
1. Master Warning Lamp (Orange or Red) 2. Hybrid System Overheated Stop Vehicle Warning
(Vehicle Information Display)
3. Hybrid System Warning Lamp (Orange) 4. READY Indicator (Green)Lamp Name
Icon Description
READ
Y Indicator
(Green) This lamp is on when the high-voltage system is powered up
and

the vehicle is ready to drive.
Master Warning Lamp
(Orange or Red) This lamp is on when another warning lamp or message is dis-
played

in the instrument cluster.
Hybrid System
Warning Lamp
(Orange) This lamp is on or blinking when:


Malfunction has occurred in the hybrid control system and/or
• High-voltage leak to vehicle chassis and/or
• Emergency shut-off system has been activated. The shut-off system activates in the following conditions:
– Front and side collisions in which the air bags are deployed.
– Certain rear collisions.
– Certain high-voltage system malfunctions. 00
0
40
80
120
160
200
240
280
km/h
MPH 20
40
1 2
3
4

5
6
7
8
9
0
PWR
RPMx1000
6080
100
120
140
160
180
1
1/2 1 2 3 4
Hybr

id System Overheated Stop Vehicle
Warning AAYIA0179ZZ
FRG–9

Page 10 of 44

2. Basic High-voltage System and 12-Volt System Information
2-1
Battery Information
The Q50 HYBRID utilizes two batteries in order to supply both high and low voltage.
2-1.1 12-Volt Battery • The Q50 HYBRID contains a conventional lead-acid12-volt battery.
• The 12-volt battery is located in the trunk, on the left side, concealed by a trim cover (A) .
• The 12-volt battery is charged by the high-voltage battery through the DC/DC converter.
2-1.2 High-voltage Battery • The Q50 HYBRID contains a high-voltage battery.
• The high-voltage battery is mounted in the trunk areabehind the rear seat, enclosed in a metal case and
concealed by trim cover.
• The high-voltage battery stores energy at approximately 346 - 400 volts DC.
• A vent hose is provided to exhaust gasses outside the vehicle if necessary.
• An air vent (A) is located on the rear left hand lower C-pillar trim for battery cooling.
The high-voltage battery supplies power to the following: • High-voltage harnesses
• DC/DC converter
• Traction motor inverter
• Traction motor
• Electric air conditioner compressor A
AAYIA0180ZZ AAYIA0183ZZ
A
AAYIA0184ZZ
FRG–10

Page 12 of 44

No. Component
Location Description
High-voltage
Battery
T
runk area (behind
rear seat back) The high-voltage battery stores and outputs DC
power (Maximum voltage 400V) needed to pro-
pel the vehicle.
DC/DC Converter Trunk area (mounted to top
of high-voltage
battery) The DC/DC converter reduces the voltage of
the high-voltage battery to provide power to the
12-volt battery in order to operate the vehicle’s
electric components (headlights, audio system,
etc.) .
Service Plug Trunk area (below
parcel shelf;
behind access
door in trim panel) This is used to disable the high-voltage system.
12-volt Battery Trunk area (left
side behind trim
panel) A lead-acid battery that supplies power to the
low voltage devices.
High-voltage
Harnesses Trunk area (on
high-voltage
battery) , under
floor pan, engine
compartment Orange-colored power cables carry high DC
voltage between each of the high-voltage com-
ponents.
Electric Air Condi-
tioner Compressor Engine compart-
ment (front driver
side) Air conditioner compressor
2-3 High-voltage Battery Pack Specifications High-voltage Battery Specifications
High-voltage

battery voltage 346V (400V max.)
Number of high-voltage battery modules in the pack 12 modules (96 cells)
High-voltage battery module voltage 28.8V each
High-voltage battery dimensions
29.63 x 17.81 x 14.85 in. (752.5 x 452.4 x 377.1 mm)
High-voltage battery weight 108.05 lbs (49 kg)
FRG–12

Page 19 of 44

3-3 How to Handle a Damaged Vehicle at an Accident Scene
NO
TE:
If any air bags have deployed in the following 3 situations, the high-voltage (HV) system has
been designed to automatically shut off at the time of deployment.
The Infiniti Q50 HYBRID high-voltage system incorporates capacitors which are energized whenever the
high-voltage system is on. If the high-voltage system is shut down (either through one of the built-in
automatic mechanisms or manually through one of the procedures explained in this FRG) , the capacitors
will begin to gradually discharge. Complete discharge requires approximately 10 minutes after
high-voltage system shut down. It is within this period of time that responders must be most cautious.
When arriving to an incident involving an Infiniti Q50 HYBRID, the vehicle should be approached with
caution and inspected for the level of damage. In addition to overall vehicle condition (location and severity
of body damage, air bag deployment, etc.) , the high-voltage system should be assessed specifically.
The locations of the high-voltage component parts are illustrated in this FRG. Refer to 2-2 High-voltage-
Related

and 12-Volt-Related Component Locations and Descriptions (FRG–11) . Appropriate personal pro-
tective

equipment (PPE) must always be worn when approaching a vehicle of unknown condition, as
described in this FRG.
Situation 1) High-voltage system intact, occupants can be accessed without extrication tools
The HV system can be shut down by following the procedure in this guide, while wearing appropriate PPE.
After HV system shut down, occupant assistance can begin immediately, and no wait period is necessary.
Situation 2) High-voltage system intact, occupants cannot be accessed without extrication tools
The HV system can be shut down by following the procedure in this guide, while wearing appropriate PPE.
After HV system shut down, absolute care must be taken never to cut through or damage any HV system
wiring, battery or components within approximately ten (10) minutes of HV system shut down,
but occupant assistance operations using extrication equipment can begin immediately. The locations of the
HV components are illustrated in this guide.
Situation 3) High-voltage (HV) system damaged
If there is any evidence that the HV system has been compromised (such as arcing/sparking, orange wiring
harnesses cut or damaged, HV component casings damaged, etc.) , the responder may still be at risk of
high-voltage exposure. The vehicle must be approached with extreme caution prior to initiating any system
shut down procedures or rendering assistance to occupants. Appropriate PPE must always be worn as
described in this guide, and the approximate ten (10) minute wait time must be observed after HV
system shut down in order to ensure the system is de-energized.
In rare situations where vehicle damage is very severe, HV system shut down procedures as described in
this guide may not work. In these instances extreme caution and appropriate risk management must be
followed to prevent shock or electrocution to the responder or occupant.
FRG–19

Page 33 of 44

SRS Air Bag System Components Location
Avoid
cutting air bag system parts. However, the vehicle can be cut (except inflators) under the following
conditions: • The front, side and curtain air bags have deployed.
• At least three (3) minutes have passed after the 12-volt battery negative (-) cable has beendisconnected and the high-voltage system has been shut down. = Inflators
(Peel
back plastic trim parts prior to cutting operation to confirm exact inflator location.) = Sensors
AAYIA0188ZZ
FRG–33

Page 35 of 44

Vehicle Cut Sheet



1-800-662-6200 (US) or 1-800-361-4792 (Canada)
Hours of Operation: 8am-5pm (Monday-Friday) Eastern, Central and Pacific Time ZonesInfiniti Emergency Contact
Never cut high-voltage
components/batteries identified as
"NEVER CUT" for any reason. Death or serious personal injury will result. High-voltage component
or harness (Can be cut
only after the high-voltage
system shut-down
procedure has been
completed.)
Electric Air Conditioner
Compressor High-voltage
battery
High-voltage
harness
Traction Motor
Inverter
Electric Air Conditioner
Compressor
Traction
Motor
Nissan North America, Inc. Version (2) July 2014
Key
voltage component NEVER CUT-High-
12-volt battery
DANGER
12-volt
battery
AAYIA0157GB
FRG–35

Page 37 of 44

3-3.5 High-voltage Battery Damage And Fluid Leaks
The high-voltage battery contains electrolyte solution. To avoid exposure to electrolyte
solution
and serious personal injury, always wear appropriate solvent resistant Personal
Protective Equipment (PPE) and read the following precautions:
• Electrolyte solution is a skin irritant.
• Electrolyte solution is an eye irritant – If contact with eyes, rinse with plenty of water and
see a doctor immediately.
• If electrolyte leak occurs, wear appropriate solvent resistant PPE and use a dry cloth to clean up the spilled electrolyte. Be sure to adequately ventilate the area.
• Electrolyte solution is highly flammable.
• Electrolyte liquid or fumes that have come into contact with water vapors in the air will create an oxidized substance. This substance may irritate skin and eyes. In these cases,
rinse with plenty of water and see a doctor immediately.
• Electrolyte fumes (when inhaled) can cause respiratory irritation and acute intoxication. Move to fresh air and wash mouth with water. See a doctor immediately.
If electrolyte solution leakage, or damage such as any problem with the high-voltage battery casing are
observed, first responders should attempt to neutralize the battery by applying a large volume of water to the
battery pack while wearing appropriate Personal Protective Equipment (PPE) . The neutralization process
helps stabilize the thermal condition of the battery pack but does not discharge the battery.
High-voltage Battery Electrolyte Solution Characteristics: • Clear in color
• Sweet odor
• Similar viscosity to water
• Since the high-voltage battery is made up of many small sealed battery modules, electrolyte solutionleakage should be minimal.
NOTE:
Other fluids in the vehicle (such as engine oil, washer fluid, brake fluid, coolant, etc.) are
the same as those in a conventional vehicle.
FRG–37