14. Touch "OK" on "WRITE CONFIGURATION" screen.
WRITE CONFIGURATION is completed.
Removal and Installation of BCMEKS007GK
REMOVAL
NOTE:
If possible, before removing BCM, retrieve current BCM configuration to use for reference when configuring
brand-new BCM after installation. Refer to BCS-13, "
Configuration" .
1. Disconnect negative battery cable.
2. Remove lower knee protector LH. Refer to IP-10, "
INSTRUMENT PANEL ASSEMBLY" .
3. Remove screw and release BCM.
4. Disconnect connectors and then remove BCM.
INSTALLATION
Installation is in the reverse order of removal.
NOTE:
When replacing BCM, it must be configured. Refer to BCS-13, "Configuration" .
When replacing BCM, perform initialization of NATS system and registration of all NATS ignition key IDs.
Refer to BL-138, "
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)" .
When replacing BCM, perform ID registration procedure of low tire pressure warning system. Refer to
WT-13, "
ID Registration Procedure" .
LKIA0400E
LEIA0068E

Page 782 of 3371

POWER DOOR LOCK SYSTEM
BL-17
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
System DescriptionEIS002R9
Power is supplied at all times
to BCM terminal 70
through 50A fusible link (letter f, located in the fuse and fusible link box) and
to BCM terminal 57
through 15A fuse [No. 22, located in the fuse block (J/B)] and
to key switch and key lock solenoid terminal 3
through 10A fuse [No. 19, located in the fuse block (J/B)].
With ignition key inserted, power is supplied
to BCM terminal 37
through key switch and key lock solenoid terminals 3 and 4
through 10A fuse [No. 19, located in fuse block (J/B)].
Ground is supplied to terminal 67 of BCM through body grounds M57, M61 and M79.
When the door is locked or unlocked with main power window and door lock/unlock switch, ground is supplied
to CPU of main power window and door lock/unlock switch
through main power window and door lock/unlock switch terminal 17
through grounds M57, M61 and M79.
Then main power window and door lock/unlock switch operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
When the door is locked or unlocked with power window and door lock/unlock switch RH, ground is supplied
to CPU of power window and door lock/unlock switch RH
through power window and door lock/unlock switch RH terminal 11
through grounds M57, M61 and M79.
Then power window and door lock/unlock switch RH operation signal is supplied
to BCM terminal 22
through power window and door lock/unlock switch RH terminal 16.
When the door is locked with front door lock assembly LH (key cylinder switch), ground is supplied
to main power window and door lock/unlock switch terminal 4
through front door lock assembly LH (key cylinder switch) terminals 1 and 5
through grounds M57, M61 and M79.
Then front door lock assembly LH (key cylinder switch) operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
When the door is unlocked with front door lock assembly LH (key cylinder switch), ground is supplied
to main power window and door lock/unlock switch terminal 6
through front door lock assembly LH (key cylinder switch) terminals 6 and 5
through grounds M57, M61 and M79.
Then front door lock assembly LH (key cylinder switch) operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
BCM is connected to main power window and door lock/unlock switch and power window and door lock/unlock
switch RH through a serial link.
When the front door switch LH is ON (door is open), ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through front door switch LH case ground.
When the front door switch RH is ON (door is open), ground is supplied
to BCM terminal 12

Page 783 of 3371

BL-18
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
through front door switch RH terminal 2
through front door switch RH case ground.
When the rear door switch LH is ON (door is open), ground is supplied
to BCM terminal 48
through rear door switch LH terminal 2
through rear door switch LH case ground.
When the rear door switch RH is ON (door is open), ground is supplied
to BCM terminal 13
through rear door switch RH terminal 2
through rear door switch RH case ground.
When the back door latch (door ajar switch) is ON (door is open), ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7
through back door latch (door ajar switch) terminal 8
through grounds B7 and B19.
OUTLINE
Functions available by operating the door lock and unlock switches on driver door and pas-
senger door
Interlocked with the locking operation of door lock and unlock switch, door lock actuators of all doors and
glass hatch actuator are locked.
Interlocked with the unlocking operation of door lock and unlock switch, door lock actuators of all doors
and glass hatch actuator are unlocked.
Functions available by operating the front door lock assembly LH (key cylinder switch)
Interlocked with the locking operation of door key cylinder, door lock actuators of all doors are locked.
When door key cylinder is unlocked, front door lock assembly LH (actuator) is unlocked.
When door key cylinder is unlocked for the second time within 5 seconds after the first operation, door
lock actuators on all doors are unlocked.
Key reminder door system
When door lock and unlock switch is operated to lock doors with ignition key in key cylinder and any door
open, all door lock actuators are locked and then unlocked.

Page 790 of 3371

POWER DOOR LOCK SYSTEM
BL-25
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Terminals and Reference Value for BCMEIS002RC
Work FlowEIS002RD
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-17, "
System Description" .
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to BL-29,
"Trouble Diagnoses Symptom Chart" .
4. Does power door lock system operate normally? OK: GO TO 5, NG: GO TO 3.
5. Inspection End.
Te r m i -
nalWire
ColorItem ConditionVoltage (V)
(Approx.)
12 R/L Front door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
13 GR Rear door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
22 W/V Power window serial linkWhen ignition switch is ON or power
window timer operates
30 Y/BR Glass hatch switchGlass hatch switch released →
Glass hatch switch pressedBattery voltage → 0
37 B/RKey switch and key lock sole-
noid (insert)Key inserted in IGN key cylinder (ON) →
Key removed from IGN key cylinder
(OFF)Battery voltage → 0
39 W CAN-H — —
40 R CAN-L — —
43 R/BBack door latch (door ajar
switch) Door open (ON) → Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
53 L/W Glass hatch lock actuatorGlass hatch switch released →
Glass hatch switch pressed0 → Battery voltage for 300 ms
57 Y/R Battery power supply — Battery voltage
59 GFront door lock assembly LH
(actuator) (unlock)Driver door lock knob
(locked → unlocked)0 → Battery voltage
65 V All door lock actuators (lock) Driver door lock knob (neutral → lock) 0 → Battery voltage
66 G/YFront door lock actuator RH,
rear door lock actuators LH/RH
and back door lock actuator
(unlock)Door lock and unlock switch (locked →
unlocked)0 → Battery voltage
67 B Ground — —
70 W/B Battery power supply — Battery voltage
PIIA2344E

Page 791 of 3371

BL-26
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
CONSULT–II Function (BCM)EIS002RE
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT–II INSPECTION PROCEDURE
CONSULT-II can display each diagnostic item using the following diagnostic test modes: data monitor, active
test, and CAN diagnostic support monitor through data reception and command transmission via the BCM
communication line.
"DOOR LOCK"
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to the
data link connector.
3. Turn ignition switch ON.
4. Touch “START (NISSAN BASED VHCL)”.
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E

Page 792 of 3371

POWER DOOR LOCK SYSTEM
BL-27
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
5. Touch “BCM”.
If "BCM" is not indicated, refer to GI-39, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
6. Touch “DOOR LOCK”.
7. Select diagnosis mode.
“DATA MONITOR” and “ACTIVE TEST” are available.
DATA MONITOR
BCIA0030E
LIIA1137E
BCIA0031E
Monitor item "OPERATION" Content
KEY ON SW "ON/OFF" Indicates [ON/OFF] condition of key switch.
CDL LOCK SW "ON/OFF" Indicates [ON/OFF] condition of lock signal from lock/unlock switch LH and RH.
CDL UNLOCK SW "ON/OFF" Indicates [ON/OFF] condition of unlock signal from lock/unlock switch LH and RH.
KEY CYL LK-SW "ON/OFF" Indicates [ON/OFF] condition of lock signal from key cylinder.
KEY CYL UN-SW "ON/OFF" Indicates [ON/OFF] condition of unlock signal from key cylinder.
IGN ON SW "ON/OFF" Indicates [ON/OFF] condition of ignition switch.
DOOR SW–DR "ON/OFF" Indicates [ON/OFF] condition of front door switch LH.
DOOR SW–AS "ON/OFF" Indicates [ON/OFF] condition of front door switch RH.
DOOR SW–RR "ON/OFF" Indicates [ON/OFF] condition of rear door switch RH.
DOOR SW–RL "ON/OFF" Indicates [ON/OFF] condition of rear door switch LH.
BACK DOOR SW "ON/OFF" Indicates [ON/OFF] condition of back door latch (door ajar switch).
KEYLESS LOCK "ON/OFF" Indicates [ON/OFF] condition of lock signal from keyfob.
KEYLESS UNLOCK "ON/OFF" Indicates [ON/OFF] condition of unlock signal from keyfob.

Page 795 of 3371

BL-30
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connector M20 terminals 57, 70
and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GROUND CIRCUIT
Check continuity between BCM connector M20 terminal 67 and
ground.
OK or NG
OK >> Power supply and ground circuit is OK.
NG >> Repair or replace harness.
ConnectorTe r m i n a l s
(Wire color)Voltage (V)
(Approx.)
(+) (-)
M2057 (Y/R)
Ground Battery voltage
70 (W/B)
LIIA1039E
ConnectorTe r m i n a l s
(Wire color)Continuity
M20 67 (B) Ground Yes
LIIA1040E

Page 797 of 3371

BL-32
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
2. CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM.
3. Check continuity between door switch connector (B) B8 (front LH), B108 (front RH), B18 (rear LH), B116
(rear RH) terminal 2 or back door latch connector (C) D503 terminal 7 and BCM connectors (A) M18, M19
terminals 12, 13, 43, 47 and 48.
4. Check continuity between door switch connector (B) B8 (front
LH), B108 (front RH), B18 (rear LH), B116 (rear RH) terminal 2
or back door latch connector (C) D503 terminal 7 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR SWITCHES
FRONT AND REAR DOORS
Check continuity between front or rear door switch terminal 2 and
exposed metal of switch while pressing and releasing switch.
BACK DOOR
Check continuity between back door latch connector (A) D503 termi-
nals 7 and 8 while pressing (closing back door) and releasing (open-
ing back door) switch.
OK or NG
OK >> (Front and rear doors) Switch circuit is OK.
OK >> (Back door) GO TO 4.
NG >> Replace door switch.2 (R/L) - 12 (R/L) : Continuity should exist.
2 (GR) - 13 (GR) : Continuity should exist.
2 (SB) - 47 (SB) : Continuity should exist.
2 (R/Y) - 48 (R/Y) : Continuity should exist.
7 (R/W) - 43 (R/B) : Continuity should exist.
2 (SB, R/L, R/Y or GR) - Ground : Continuity should not
exist.
7 (R/W) - Ground : Continuity should not
exist.
WIIA0750E
Door switch is released : Continuity should exist.
Door switch is pushed : Continuity should not exist.
WIIA0644E
When back door is open : Continuity should exist.
When back door is closed : Continuity should not exist.
WIIA0752E

Page 798 of 3371

POWER DOOR LOCK SYSTEM
BL-33
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Key Switch (Insert) CheckEIS0 02 RI
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.8 (B) - Ground : Continuity should exist.
LIIA0828E
KEY ON SW :ON
KEY ON SW :OFF
LIIA0169E
ConnectorTerminal (Wire color)
Condition Voltage (V)
(+) (–)
M18 37 (B/R) GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E

Page 799 of 3371

BL-34
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid.
3. Check continuity between key switch and key lock solenoid terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.
Door Lock/Unlock Switch CheckEIS002RJ
1. CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
With CONSULT-II
Check door lock/unlock switch ("CDL LOCK SW", "CDL UNLOCK SW") in DATA MONITOR mode in CON-
SULT–II. Refer to BL-27, "
DATA MONITOR"
When door lock/unlock switch is turned to LOCK:
When door lock/unlock switch is turned to UNLOCK:
Without CONSULT-II
1. Remove key from ignition key cylinder.
2. Check the signal between BCM connector M18 terminal 22 and ground with oscilloscope when door lock/
unlock switch is turned to LOCK or UNLOCK.
3. Make sure the signals which are shown in the figure below can be detected during 10 seconds just after
the door lock/unlock switch is turned to LOCK or UNLOCK.
OK or NG
OK >> Door lock and unlock switch circuit is OK.
NG >> GO TO 2.
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E
CDL LOCK SW :ON
CDL UNLOCK SW :ON
PIIA6538E
ConnectorTerminal (Wire color)
Voltage (V)
(+) (–)
M18 22 (W/V) Ground
PIIA6379EPIIA1297E