Ins INFINITI QX56 2004 Factory Service Manual

Page 782 of 3371

POWER DOOR LOCK SYSTEM
BL-17
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
System DescriptionEIS002R9
Power is supplied at all times
to BCM terminal 70
through 50A fusible link (letter f, located in the fuse and fusible link box) and
to BCM terminal 57
through 15A fuse [No. 22, located in the fuse block (J/B)] and
to key switch and key lock solenoid terminal 3
through 10A fuse [No. 19, located in the fuse block (J/B)].
With ignition key inserted, power is supplied
to BCM terminal 37
through key switch and key lock solenoid terminals 3 and 4
through 10A fuse [No. 19, located in fuse block (J/B)].
Ground is supplied to terminal 67 of BCM through body grounds M57, M61 and M79.
When the door is locked or unlocked with main power window and door lock/unlock switch, ground is supplied
to CPU of main power window and door lock/unlock switch
through main power window and door lock/unlock switch terminal 17
through grounds M57, M61 and M79.
Then main power window and door lock/unlock switch operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
When the door is locked or unlocked with power window and door lock/unlock switch RH, ground is supplied
to CPU of power window and door lock/unlock switch RH
through power window and door lock/unlock switch RH terminal 11
through grounds M57, M61 and M79.
Then power window and door lock/unlock switch RH operation signal is supplied
to BCM terminal 22
through power window and door lock/unlock switch RH terminal 16.
When the door is locked with front door lock assembly LH (key cylinder switch), ground is supplied
to main power window and door lock/unlock switch terminal 4
through front door lock assembly LH (key cylinder switch) terminals 1 and 5
through grounds M57, M61 and M79.
Then front door lock assembly LH (key cylinder switch) operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
When the door is unlocked with front door lock assembly LH (key cylinder switch), ground is supplied
to main power window and door lock/unlock switch terminal 6
through front door lock assembly LH (key cylinder switch) terminals 6 and 5
through grounds M57, M61 and M79.
Then front door lock assembly LH (key cylinder switch) operation signal is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
BCM is connected to main power window and door lock/unlock switch and power window and door lock/unlock
switch RH through a serial link.
When the front door switch LH is ON (door is open), ground is supplied
to BCM terminal 47
through front door switch LH terminal 2
through front door switch LH case ground.
When the front door switch RH is ON (door is open), ground is supplied
to BCM terminal 12

Page 790 of 3371

POWER DOOR LOCK SYSTEM
BL-25
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Terminals and Reference Value for BCMEIS002RC
Work FlowEIS002RD
1. Check the symptom and customer's requests.
2. Understand the outline of system. Refer to BL-17, "
System Description" .
3. According to the trouble diagnosis chart, repair or replace the cause of the malfunction. Refer to BL-29,
"Trouble Diagnoses Symptom Chart" .
4. Does power door lock system operate normally? OK: GO TO 5, NG: GO TO 3.
5. Inspection End.
Te r m i -
nalWire
ColorItem ConditionVoltage (V)
(Approx.)
12 R/L Front door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
13 GR Rear door switch RH Door open (ON) → Door close (OFF) 0 → Battery voltage
22 W/V Power window serial linkWhen ignition switch is ON or power
window timer operates
30 Y/BR Glass hatch switchGlass hatch switch released →
Glass hatch switch pressedBattery voltage → 0
37 B/RKey switch and key lock sole-
noid (insert)Key inserted in IGN key cylinder (ON) →
Key removed from IGN key cylinder
(OFF)Battery voltage → 0
39 W CAN-H — —
40 R CAN-L — —
43 R/BBack door latch (door ajar
switch) Door open (ON) → Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
53 L/W Glass hatch lock actuatorGlass hatch switch released →
Glass hatch switch pressed0 → Battery voltage for 300 ms
57 Y/R Battery power supply — Battery voltage
59 GFront door lock assembly LH
(actuator) (unlock)Driver door lock knob
(locked → unlocked)0 → Battery voltage
65 V All door lock actuators (lock) Driver door lock knob (neutral → lock) 0 → Battery voltage
66 G/YFront door lock actuator RH,
rear door lock actuators LH/RH
and back door lock actuator
(unlock)Door lock and unlock switch (locked →
unlocked)0 → Battery voltage
67 B Ground — —
70 W/B Battery power supply — Battery voltage
PIIA2344E

Page 791 of 3371

BL-26
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
CONSULT–II Function (BCM)EIS002RE
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT–II INSPECTION PROCEDURE
CONSULT-II can display each diagnostic item using the following diagnostic test modes: data monitor, active
test, and CAN diagnostic support monitor through data reception and command transmission via the BCM
communication line.
"DOOR LOCK"
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. Turn ignition switch OFF.
2. Connect CONSULT-II and CONSULT-II CONVERTER to the
data link connector.
3. Turn ignition switch ON.
4. Touch “START (NISSAN BASED VHCL)”.
BCM
diagnostic test itemDiagnostic mode Description
Inspection by partWORK SUPPORTSupports inspections and adjustments. Commands are transmitted to the
BCM for setting the status suitable for required operation, input/output sig-
nals are received from the BCM and received date is displayed.
DATA MONITOR Displays BCM input/output data in real time.
ACTIVE TESTOperation of electrical loads can be checked by sending drive signal to
them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTRThe result of transmit/receive diagnosis of CAN communication can be
read.
ECU PART NUMBER BCM part number can be read.
CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E

Page 794 of 3371

POWER DOOR LOCK SYSTEM
BL-29
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Trouble Diagnoses Symptom ChartEIS0 02 RF
BCM Power Supply and Ground Circuit CheckEIS002RG
1. CHECK FUSE AND FUSIBLE LINK
Check the following BCM fuse and fusible link.
NOTE:
Refer to BL-101, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
Symptom Repair order Refer to page
Key reminder door function does not operate
properly.1. Door switch checkBL-31
2. Key switch (insert) checkBL-33
3. Replace BCM.BCS-19
Power door lock does not operate with door lock
and unlock switch on main power window and
door lock/unlock switch or power window and
door lock/unlock switch RH.1. Door lock/unlock switch checkBL-34
Front door lock assembly LH (actuator) does not
operate.1. Front door lock assembly LH (Actuator) checkBL-37
Specific door lock actuator does not operate.1. Front door lock actuator RH checkBL-392. Rear door lock actuator RH/LH checkBL-40
Power door lock does not operate with front door
key cylinder LH operation.1. Front door lock assembly LH (key cylinder
switch) checkBL-42
2. Replace BCM.BCS-19
Power door lock does not operate.1. BCM power supply and ground circuit checkBL-292. Door lock/unlock switch checkBL-34
Back door opener does not operate.1. Back door power supply and ground circuit
inspectionBL-1172. Door switch checkBL-31
3. Power liftgate switch system inspectionBL-118
Glass hatch lock actuator does not operate.1. Glass hatch switch checkBL-362.Glass hatch lock actuator checkBL-41
3. Replace BCM.BCS-19
Component Parts Terminal No. (SIGNAL) Ampere No. Location
BCM 57 (BAT power supply) 15A 22 Fuse block (J/B)
BCM 70 (BAT power supply) 50AfFuse and fusible link box

Page 798 of 3371

POWER DOOR LOCK SYSTEM
BL-33
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Key Switch (Insert) CheckEIS0 02 RI
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.8 (B) - Ground : Continuity should exist.
LIIA0828E
KEY ON SW :ON
KEY ON SW :OFF
LIIA0169E
ConnectorTerminal (Wire color)
Condition Voltage (V)
(+) (–)
M18 37 (B/R) GroundKey is inserted. Battery voltage
Key is removed. 0
LIIA0567E

Page 799 of 3371

BL-34
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid.
3. Check continuity between key switch and key lock solenoid terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch.
Door Lock/Unlock Switch CheckEIS002RJ
1. CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
With CONSULT-II
Check door lock/unlock switch ("CDL LOCK SW", "CDL UNLOCK SW") in DATA MONITOR mode in CON-
SULT–II. Refer to BL-27, "
DATA MONITOR"
When door lock/unlock switch is turned to LOCK:
When door lock/unlock switch is turned to UNLOCK:
Without CONSULT-II
1. Remove key from ignition key cylinder.
2. Check the signal between BCM connector M18 terminal 22 and ground with oscilloscope when door lock/
unlock switch is turned to LOCK or UNLOCK.
3. Make sure the signals which are shown in the figure below can be detected during 10 seconds just after
the door lock/unlock switch is turned to LOCK or UNLOCK.
OK or NG
OK >> Door lock and unlock switch circuit is OK.
NG >> GO TO 2.
Terminals Condition Continuity
3 – 4Key is inserted. Yes
Key is removed. No
LIIA1044E
CDL LOCK SW :ON
CDL UNLOCK SW :ON
PIIA6538E
ConnectorTerminal (Wire color)
Voltage (V)
(+) (–)
M18 22 (W/V) Ground
PIIA6379EPIIA1297E

Page 800 of 3371

POWER DOOR LOCK SYSTEM
BL-35
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
2. CHECK BCM OUTPUT SIGNAL
Check ("POWER WINDOW DOWN") in ACTIVE TEST mode for
"MULTI REMOTE ENT" with CONSULT–II. Refer to BL-28, "
ACTIVE
TEST" .
OK or NG
OK >> GO TO 3.
NG >> Replace BCM. Refer to BCS-19, "
Removal and Installa-
tion of BCM" .
3. CHECK DOOR LOCK/UNLOCK SWITCH GROUND HARNESS
1. Turn ignition switch OFF.
2. Disconnect main power window and door lock/unlock switch or power window and door lock/unlock switch
RH
3. Check continuity between main power window and door lock/
unlock switch connector D8 terminal 17 and ground.
4. Check continuity between power window and door lock/unlock
switch RH connector D105 terminal 11 and ground
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.When "ACTIVE TEST" is performed, are the front win-
dows lowered?
PIIA3080E
17 (B) - Ground : Continuity should exist.
LIIA0392E
11 (B) - Ground : Continuity should exist.
LIIA1140E

Page 801 of 3371

BL-36
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
4. CHECK POWER WINDOW SERIAL LINK CIRCUIT
1. Disconnect BCM.
2. Check continuity between BCM connector M18 terminal 22 and
main power window and door lock/unlock switch connector D7
terminal 14.
3. Check continuity between BCM connector M18 terminal 22 and
power window and door lock/unlock switch RH connector D105
terminal 16.
OK or NG
OK >> Replace main power window and door lock/unlock
switch or power window and door lock/unlock switch RH
NG >> Repair or replace harness.
Glass Hatch Switch Circuit InspectionEIS005X5
1. CHECK GLASS HATCH SWITCH
1. Turn ignition switch OFF.
2. Disconnect glass hatch switch.
3. Check continuity between glass hatch switch terminal 2 and ground.
OK or NG
OK >> GO TO 2.
NG >> Replace glass hatch switch.22 (W/V) - 14 (LG/W) : Continuity should exist.
LIIA0394E
22 (W/V) - 16 (LG/W) : Continuity should exist.
LIIA1271E
Connec-
torTe r m i n a l s
Condition Continuity
(+) (–)
D710 2 GroundWith the glass hatch switch
pressedYe s
With the glass hatch switch
releasedNo
LIIA1935E

Page 803 of 3371

BL-38
POWER DOOR LOCK SYSTEM
Revision: August 20072004 QX56
OK or NG
OK >> Replace front door lock assembly LH (actuator). Refer to BL-132, "FRONT DOOR LOCK" .
NG >> Replace BCM. Refer to BCS-19, "
Removal and Installation of BCM" .

Page 804 of 3371

POWER DOOR LOCK SYSTEM
BL-39
C
D
E
F
G
H
J
K
L
MA
B
BL
Revision: August 20072004 QX56
Front Door Lock Actuator RH CheckEIS002RL
1. CHECK FRONT DOOR LOCK ACTUATOR RH HARNESS
1. Turn ignition switch OFF.
2. Disconnect BCM and front door lock actuator RH.
3. Check continuity between BCM connector M20 terminals 65, 66
and front door lock actuator RH D114 terminals 2, 3.
4. Check continuity between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> GO TO 2.
NG >> Repair or replace harness.
2. CHECK FRONT DOOR LOCK ACTUATOR RH SIGNAL
1. Reconnect BCM.
2. Check voltage between BCM connector M20 terminals 65, 66
and ground.
OK or NG
OK >> Replace front door lock actuator RH. Refer to BL-132, "FRONT DOOR LOCK" .
NG >> Replace BCM. Refer to BCS-19, "
Removal and Installation of BCM" .
Terminal Continuity
65 (V) 3 (V) Yes
66 (G/Y) 2 (G/Y) Yes
Terminals (Wire color) Continuity
65 (V)
GroundNo
66 (G/Y) No
LIIA1479E
ConnectorTe r m i n a l s
(Wire color)
ConditionVoltage (V)
(Approx.)
(+) (-)
M2065 (V)
GroundDoor lock/unlock switch is
turned to LOCK0 → Battery voltage
for 300 ms
66 (G/Y)Door lock/unlock switch is
turned to UNLOCK0 → Battery voltage
for 300 ms
LIIA1048E