air condition INFINITI QX56 2006 Factory Service Manual
Page 878 of 3383
VEHICLE SECURITY (THEFT WARNING) SYSTEMBL-97
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
2. CHECK DOOR KEY CYLINDER SWITCH LH GROUND HARNESS
Check continuity between front door lock assembly LH (key cylinder
switch) connector (A) D14 terminal 5 and body ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK DOOR KEY CYLINDER SWITCH LH
Check continuity between front door lock assembly LH (key cylinder
switch) terminals.
OK or NG
OK >> GO TO 4.
NG >> Replace front door lock assembly LH (key cylinder switch). Refer to BL-131, "
Removal and Instal-
lation" .
4. CHECK DOOR KEY CYLINDER HARNESS
Check continuity between main power window and door lock/unlock
switch connector (A) D7 terminals 4, 6 and front door lock assembly
LH (key cylinder switch) connector (B) D14 terminals 1, 6 and body
ground.
OK or NG
OK >> Replace main power window and door lock/unlock switch.
NG >> Repair or replace harness.
Connector TerminalsContinuity
D14 5 – Ground Yes
WIIA0755E
Terminals Condition Continuity
1 – 5 Key is turned to UNLOCK or neutral.
No
Key is turned to LOCK. Yes
5 – 6 Key is turned to LOCK or neutral.
No
Key is turned to UNLOCK. Yes
LIIA1573E
Connector Terminals Connector Terminals Continuity
A: Main
power win- dow and
door lock/
unlock switch 4B: Front
door lock
assembly
LH (key
cylinder switch) 1Y
es
66Y es
4, 6 Ground No
WIIA0756E
Page 883 of 3383
BL-102
AUTOMATIC BACK DOOR SYSTEM
Revision: November 20092006 QX56
Back Door Close Switch Operation (Fully Open → Fully Closed Operation)
When the back door close switch is pressed, the back door control unit terminal 8 receives the signal.
The back door control units checks back door close switch terminal 13 status and door position (must be
fully opened), through rotary encoder and battery voltage.
When the back door control unit receives the signal, if the auto back door operating enable conditions are
met, it sends a signal through terminal 6 and grounds terminal 9 to sound the warning chime and sends a
signal to the BCM through terminal 4 to flash the hazard lamps.
The back door control unit supplies power to the magnetic clutch and the back door motor and move the
back door in the close direction. (At this time, it also executes speed control, input reverse, and anti-pinch
detection control.)
When the back door reaches the half-latch state, the half-latch switch detects this and the signal is sent to
the back door control unit terminal 22.
When the back door control unit receives the half latch switch signal, it switches OFF the back door motor
and the magnetic clutch and operates the cinch latch motor.
When the back door latch operates and full close is detected through terminal 14 of the back door control
unit, the cinch latch motor reverses to the neutral position and the back door auto closure operation ends
and the door is fully closed.
Reversal
The door will reverse direction during power open or close operation if the automatic door main switch, keyfob
or back door close switch is operated. A chime will sound to announce the reversal.
Anti-Pinch Function
During auto operation, if an object is detected in the door's path, a warning chime sounds and the back
door operates in the reverse direction to prevent pinching.
During auto close operation, if an object is detected by the pinch strips in the door's path, a warning chime
sounds and the back door operates in the open direction until it is fully open.
Gas Stay Check
During each power open operation, the back door control unit monitors motor current draw to determine if
the gas stays are functioning properly.
If a malfunction of the gas stays is detected, the back door control unit will close the back door while
sounding the warning chime. The back door cannot be opened using the switches until the gas stay mal-
function is repaired.
Warning Functions
The hazard warning lamps flash and a warning chime is sounded according to the back door operating
state, operations, and conditions.
Page 897 of 3383
BL-116
AUTOMATIC BACK DOOR SYSTEM
Revision: November 20092006 QX56
Power Liftgate Switch System InspectionEIS00616
1. POWER LIFTGATE SWITCH FUNCTION INSPECTION
Check power liftgate switch using switch operation.
OK or NG
OK >> Power liftgate switch is OK.
NG >> GO TO 2.
2. POWER LIFTGATE SWITCH POWER SUPPLY CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. Check voltage between power liftgate switch connector M92 ter- minal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. POWER LIFTGATE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the power liftgate switch, check voltage between back door control unit connector B55 terminal 23 and
ground.
OK or NG
OK >> Switch is OK.
NG >> GO TO 4.
4. POWER LIFTGATE SWITCH CIRCUIT INSPECTION
1. Disconnect power liftgate switch and back door control unit connector.
2. Check continuity between power liftgate switch connector M92 terminal 1 and back door control unit connector B55 terminal 23.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness. 1 - Ground
:Approx. battery voltage
LIIA1551E
Terminals
ConditionVoltage (V)
(Approx.)
(+) (-)
23 GroundPower liftgate
switch ON
0
OFF 5
LIIA0802E
1 - 23 : Continuity should exist.
LIIA1064E
Page 898 of 3383
AUTOMATIC BACK DOOR SYSTEMBL-117
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
5. POWER LIFTGATE SWITCH GROUND INSPECTION
Check continuity between power liftgate switch connector terminal 2
and ground.
OK or NG
OK >> Replace the power liftgate switch.
NG >> Repair or replace harness.
GLASS HATCH AJAR SWITCH CHECK
1. CHECK GLASS HATCH AJAR SWITCH INPUT SIGNAL
With CONSULT-II
Check glass hatch ajar switch ("TRNK OPN MNTR") in DATA MONITOR mode with CONSULT –II. Refer to
BL-27, "
DATA MONITOR" .
When glass hatch is open:
When glass hatch is closed:
Without CONSULT-II
Check voltage between BCM connector M19 terminal 42 and ground.
OK or NG
OK >> System is OK.
NG >> GO TO 2. 2 - Ground
: Continuity should exist.
LIIA1065E
TRNK OPN MNTR : ON
TRNK OPN MNTR : OFF
WIIA0108E
Connector Item Terminals
ConditionVoltage (V)
(Approx.)
(+) (– )
M19 BCM 42 Ground Open
↓
Closed 0
↓
Battery voltage
LIIA1149E
Page 899 of 3383
BL-118
AUTOMATIC BACK DOOR SYSTEM
Revision: November 20092006 QX56
2. CHECK GLASS HATCH AJAR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect glass hatch ajar switch, BCM and back door control unit.
3. Check continuity between glass hatch ajar switch connector D707 terminal + and BCM connector M19 ter- minal 42.
4. Check continuity between glass hatch ajar switch connector D707 terminal + and back door control unit connector B55 termi-
nal 17.
5. Check continuity between glass hatch ajar switch connector D707 terminal + and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CHECK GLASS HATCH AJAR SWITCH
1. Disconnect glass hatch ajar switch connector.
2. Check continuity between glass hatch ajar switch connector terminal and ground.
OK or NG
OK >> Check glass hatch ajar switch case ground condition.
NG >> Replace glass hatch ajar switch, or repair or replace harness.
Back Door Close (Close) Switch System InspectionEIS00617
1. BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (close) switch using switch operation.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 2. + - 42
: Continuity should exist
+ - 17 : Continuity should exist
+ - Ground : Continuity should not exist
LIIA1547E
Terminals Condition Continuity
Glass hatch ajar switch +
– Ground Open
Yes
Closed No
LIIA1151E
Page 900 of 3383
AUTOMATIC BACK DOOR SYSTEMBL-119
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
2. BACK DOOR CLOSE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close switch, check voltage between back door control unit connector B55 terminal 8 and
ground.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 3.
3. BACK DOOR CLOSE SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door close switch connector B63 terminal 1 and back door control unit connector B55 terminal 8.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. BACK DOOR CLOSE SWITCH GROUND INSPECTION
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
OK or NG
OK >> Replace the back door close switch.
NG >> Repair or replace harness.
Back Door Close (Cancel) Switch System InspectionEIS00618
1. BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (cancel) switch using switch operation.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 2.
Te r m i n a l s ConditionVoltage (V)
(Approx.)
(+) (-)
8 Ground Back door
close
switch ON 0
OFF Battery voltage
LIIA0805E
1 - 8 : Continuity should exist.
LIIA1066E
3 - Ground: Continuity should exist.
WIIA0602E
Page 901 of 3383
BL-120
AUTOMATIC BACK DOOR SYSTEM
Revision: November 20092006 QX56
2. BACK DOOR CLOSE (CANCEL) SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close (cancel) switch, check volt- age between back door control unit connector B55 terminal 13
and ground.
OK or NG
OK >> Back door close switch is OK.
NG >> GO TO 3.
3. BACK DOOR CLOSE (CANCEL) SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door close switch connector B63 terminal 5 and back door control unit connector B55 terminal 13.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. BACK DOOR CLOSE SWITCH GROUND INSPECTION
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
OK or NG
OK >> Replace the back door close switch.
NG >> Repair or replace harness.
Terminals ConditionVoltage (V)
(Approx.)
(+) (-)
13 Ground Back door
close switch ON
0
OFF 5
LIIA1068E
5 - 13 : Continuity should exist.
LIIA1069E
3 - Ground: Continuity should exist.
WIIA0602E
Page 902 of 3383
AUTOMATIC BACK DOOR SYSTEMBL-121
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Pinch Strip System InspectionEIS00619
1. PINCH STRIP SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the pinch strip, check voltage between back door control unit connector B55 terminals 19, 20 and ground.
OK or NG
OK >> Pinch strip switch is OK.
NG >> GO TO 2.
2. PINCH STRIP CIRCUIT INSPECTION
1. Disconnect pinch strip and back door control unit.
2. Check continuity between pinch strip connector D715 (RH), D517 (LH) terminal 1, 2 and back door control unit connector
B55 terminal 5, 19 (RH), 20 (LH).
OK or NG
OK >> GO TO 3.
NG >> Repair the harness between the pinch strip and the back door control unit.
3. PINCH STRIP GROUND INSPECTION
1. Connect back door control unit connector.
2. Check continuity between pinch strip connector terminal 2 and ground.
OK or NG
OK >> Replace the pinch strip.
NG >> Repair or replace harness.
Te r m i n a l s ConditionVoltage (V)
(Approx.)
(+) (-)
19
20 Ground Pinch strip operation
0
Other 4
LIIA0811E
1 - 19 : Continuity should exist.
1 - 20 : Continuity should exist.
2 - 5 : Continuity should exist.
LIIA0815E
2 - Ground: Continuity should exist.
LIIA0817E
Page 906 of 3383
AUTOMATIC BACK DOOR SYSTEMBL-125
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
2. CLOSE SWITCH CIRCUIT INSPECTION
1. Disconnect back door latch and back door control unit.
2. Check continuity between back door latch (close switch) con- nector D503 terminal 5 and back door control unit connector
B55 terminal 14.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3. CLOSE SWITCH GROUND INSPECTION
Check continuity between back door latch (close switch) connector
D503 terminal 8 and ground.
OK or NG
OK >> Replace the back door latch.
NG >> Repair or replace harness.
Back Door Handle Switch System InspectionEIS0061E
1. BACK DOOR HANDLE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door handle switch, check voltage between back door control unit connector B55 terminal 26 and
ground.
OK or NG
OK >> Back door handle switch is OK.
NG >> GO TO 2. 5 - 14
: Continuity should exist.
LIIA0832E
8 - Ground: Continuity should exist.
LIIA0828E
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
26 Ground Back door handle switch (ON)
0
Other (OFF) Battery voltage
LIIA0833E
Page 935 of 3383
BL-154
IVIS (INFINITI VEHICLE IMMOBILIZER SYSTEM-NATS)
Revision: November 20092006 QX56
Diagnostic Procedure 6EIS0061U
“SECURITY INDICATOR LAMP DOES NOT LIGHT UP”
1. CHECK FUSE
Check 10A fuse [No.19, located in the fuse block (J/B)]
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of malfunction before installing new fuse.
2. CHECK SECURITY INDICATOR LAMP
1. Start engine and turn ignition switch OFF.
2. Check the security indicator lamp lights up.
OK or NG
OK >> Inspection End.
NG >> GO TO 3.
3. CHECK SECURITY INDICATOR LAMP POWER SUPPLY CIRCUIT
1. Disconnect security indicator lamp.
2. Check voltage between security indicator lamp connector M24 terminal 8 and ground.
OK or NG
OK >> GO TO 4.
NG >> Repair or replace harness.
4. CHECK BCM (NATS CONTROL UNIT) FUNCTION
1. Connect security indicator lamp.
2. Disconnect BCM.
3. Check voltage between BCM connector M18 terminal 23 and ground.
OK or NG
OK >> BCM is malfunctioning.
Replace BCM. Ref. part No. A
Perform initialization with CONSULT-II.
For initialization, refer to “CONSULT-II Operation
Manual NATS-IVIS/NVIS ”.
NG >> Check the following:
Harness for open or short between security indicator lamp and BCM (NATS control unit).
Indicator lamp condition
Security indicator lamp should light up.
8 - Ground
:Battery voltage
LIIA1072E
23 - Ground :Battery voltage
LIIA0523E