key battery INFINITI QX56 2006 Factory User Guide
Page 834 of 3383
REMOTE KEYLESS ENTRY SYSTEMBL-53
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Terminals and Reference Value for BCMEIS005ZU
Te r m i n a l Wire
Color Item
Condition Voltage (V)
(Approx.)
11 O Ignition switch (ACC or ON) Ignition switch (ACC or ON position) Battery voltage
12 R/L Front door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
13 GR Rear door switch RH Door open (ON) → Door close (OFF) Battery voltage → 0
18 P Remote keyless entry
receiver ground —
0
19 V/W Remote keyless entry
receiver (Power supply)
Ignition switch OFF
20 G/W Remote keyless entry
receiver signal (Signal) Stand-by (keyfob buttons released)
When remote keyless entry receiver
receives signal from keyfob (keyfob
buttons pressed)
37 B/R Key switch and key lock sole-
noid (insert) Key inserted in IGN key cylinder (ON)
→
Key removed from IGN key cylinder
(OFF) Battery voltage
→ 0
38 W/L Ignition switch (ON or
START) Ignition switch (ON or START posi-
tion)
Battery voltage
39 L CAN-H ——
40 P CAN-L ——
43 R/B Back door latch (door ajar
switch) Door open (ON) →
Door close (OFF) 0 → Battery voltage
47 SB Front door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
48 R/Y Rear door switch LH Door open (ON) → Door close (OFF) 0 → Battery voltage
56 R/G Battery saver
(Interior lamp) Battery saver does operated →
Does
not operated (ON → OFF) Battery voltage
→ 0
57 Y/R Battery power supply —Battery voltage
59 G Front door lock assembly LH
(actuator) (unlock) Door lock & unlock switch
(Neutral
→ Unlock) 0
→ Battery voltage
60 G/B Turn signal LH When doors are locked or unlocked
using keyfob (OFF →
ON) *2 0
→ Battery voltage
61 G/Y Turn signal RH When doors are locked or unlocked
using keyfob (OFF →
ON) *2 0
→ Battery voltage
62 R/W Step lamp LH and RH Step lamp ON
0
Step lamp OFF Battery voltage
LIIA1893E
LIIA1894E
LIIA1895E
Page 835 of 3383
BL-54
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
*1: when room lamp switch is in "DOOR" position.
*2: when hazard reminder is ON.
Terminals and Reference Value for IPDM E/REIS005ZV
*: when horn reminder is ON.63 L Room lamp
Room lamp ON *1
Battery voltage
Room Lamp OFF *1 0
65 V All door lock actuators (lock) Door lock & unlock switch
(Neutral
→ Lock) 0
→ Battery voltage
66 G/Y Front door lock actuator RH,
rear door lock actuators LH/
RH and back door lock actu-
ator (unlock) Door lock & unlock switch
(Neutral
→ Unlock) 0
→ Battery voltage
67 B Ground —0
69 W/R Rear power window power
supply —
Battery voltage
70 W/B Battery power supply —Battery voltage
Te r m i n a l
Wire
Color Item
Condition Voltage (V)
(Approx.)
Te r m i n a l Wire
Color Item
Condition Voltage (V)
(Approx.)
38 B Ground —0
39 L CAN-H ——
40 P CAN-L ——
45 G/W Horn relay When doors locks are operated
using keyfob (OFF →
ON) * Battery voltage
→ 0
59 B Ground —0
Page 840 of 3383
REMOTE KEYLESS ENTRY SYSTEMBL-59
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Trouble Diagnosis ProcedureEIS005ZZ
1. Check the symptom and customer's requests.
2. Understand outline of system. Refer to BL-45, "
System Description" .
3. Confirm system operation.
Check that the power door lock system operates normally. Refer to BL-16, "POWER DOOR LOCK
SYSTEM" .
Check that the automatic back door system operates normally. Refer to BL-99, "AUTOMATIC BACK
DOOR SYSTEM" .
4. Perform pre-diagnosis inspection. Refer to BL-59, "
BCM Power Supply and Ground Circuit Check" .
5. Refer to trouble diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-60,
"Trouble Diagnoses" .
6. Inspection End.
BCM Power Supply and Ground Circuit CheckEIS00600
1. CHECK FUSE AND FUSIBLE LINK
Check the following BCM fuses and fusible link.
NOTE:
Refer to BL-44, "
Component Parts and Harness Connector Location" .
OK or NG
OK >> GO TO 2.
NG >> If fuse is blown, be sure to eliminate cause of problem before installing new fuse, refer to PG-4,
"POWER SUPPLY ROUTING CIRCUIT" .
2. CHECK POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect BCM.
3. Check voltage between BCM connectors M18, M20 terminals 11, 38, 57, 70 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
Component Parts Terminal No. (SIGNAL) AmpereNo. Location
BCM 57 (BAT power supply)
15A22 Fuse block (J/B)
70 (BAT power supply) 50AfFuse and fusible link box
11 (ACC power supply) 10A4 Fuse block (J/B)
38 (IGN power supply) 10A59 Fuse and relay box
ConnectorTerminals
Signal nameIgnition
switch Vo l ta g e
(+) ( –)
M20 70
Ground Battery power
supply OFFBattery
voltage
57 Battery power
supply OFFBattery
voltage
M18 11
ACC power
supply ACC
Battery
voltage
38 IGN power
supply ONBattery
voltage
WIIA0600E
Page 841 of 3383
BL-60
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
3. CHECK GROUND CIRCUIT
Check continuity between BCM connector M20 terminal 67 and
ground.
OK or NG
OK >> Power supply and ground circuit is OK.
NG >> Repair or replace harness.
Trouble DiagnosesEIS00601
SYMPTOM CHART
NOTE:
Always check the "Trouble Diagnosis Procedure" before troubleshooting. Refer to BL-59, "Trouble Diag-
nosis Procedure" .
Always check keyfob battery before replacing keyfob. Refer to BL-65, "Keyfob Battery and Function
Check" .
The panic alarm operation and power back door opener operation of remote keyless entry system do not
activate with the ignition key inserted in the ignition key cylinder.
Use Remote Keyless Entry Tester J-43241 (follow instructions on tester) to check operation of keyfob
before replacing keyfob.
ConnectorTerminals
Continuity
(+) (-)
M20 67Ground Yes
LIIA1040E
Symptom Diagnoses/service procedureReference
page
All functions of remote keyless entry system do not
operate. 1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning. BL-65
2. Check BCM and keyless receiver.
BL-66
The new ID of keyfob cannot be entered.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.
BL-652. Key switch and key lock solenoid (insert) check
BL-62
3. Door switch checkBL-63
4. ACC power checkBL-68
5. Replace BCM.BCS-20
Door lock or unlock does not function.
(If the power door lock system does not operate
manually, check power door lock system. Refer to
BL-16, "
POWER DOOR LOCK SYSTEM" )1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.
BL-65
2. Replace BCM.
BCS-20
Hazard and horn reminder does not activate prop-
erly when pressing lock or unlock button of keyfob.1. Check hazard and horn reminder mode with CONSULT-II
NOTE:
Hazard and horn reminder mode can be changed.
First check the hazard and horn reminder mode setting.
BL-57,
"Active
Te s t"
2. Door switch check
BL-63
3. Replace BCM.BCS-20
Page 842 of 3383
REMOTE KEYLESS ENTRY SYSTEMBL-61
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Hazard reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Horn reminder OK)1. Check hazard reminder mode with CONSULT-II
NOTE:
Hazard reminder mode can be changed.
First check the hazard reminder mode setting.
BL-57
2. Check hazard function with hazard switch
—
3. Replace BCM. BCS-20
Horn reminder does not activate properly when
pressing lock or unlock button of keyfob.
(Hazard reminder OK)1. Check horn reminder mode with CONSULT-II
NOTE:
Horn reminder mode can be changed.
First check the horn reminder mode setting.
BL-57
2. Check horn function with horn switch
—
3. IPDM E/R operation check BL-68
4. Replace BCM.BCS-20
Back door open/close operation is not carried out
with keyfob operation.
(The automatic back door system is normal.)1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning.
BL-65
2. Key switch (insert) check
BL-62
3. Check that glass hatch is closed —
4. Remote keyless entry receiver system BL-66
5. Replace BCM.BCS-20
Room lamp, ignition keyhole illumination and step
lamp operation do not activate properly.1. Room lamp operation check
BL-70
2. Ignition keyhole illumination operation checkBL-70
3.Step lamp operation checkLT- 1 3 5
4. Door switch check BL-63
5. Replace BCM.BCS-20
Panic alarm (horn and headlamp) does not activate
when panic alarm button is continuously pressed.1. Keyfob battery and function check (use Remote Keyless Entry
Tester J-43241)
NOTE:
If the result of keyfob function check is OK, keyfob is not malfunc-
tioning. BL-65
2. Key switch and key lock solenoid (insert) check
BL-62
3. Replace BCM.BCS-20
Auto door lock operation does not activate properly.
(All other remote keyless entry functions OK.)1. Check auto door lock operation mode with CONSULT-II
NOTE:
Auto door lock operation mode can be changed.
First check the auto door lock operation mode setting.
BL-57
2. Replace BCM.
BCS-20
Keyless power window down (open) operation does
not activate properly.
(All other remote keyless entry functions OK.)1. Check power window down operation mode with CONSULT-II
NOTE:
Power window down operation mode can be changed.
First check the power window down operation mode setting.
BL-57
2. Check power window function with switch
—
3. Replace BCM. BCS-20
SymptomDiagnoses/service procedureReference
page
Page 843 of 3383
BL-62
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
Key Switch (Insert) CheckEIS00602
1. CHECK KEY SWITCH INPUT SIGNAL
With CONSULT-II
Check key switch "KEY ON SW" in DATA MONITOR mode with CONSULT –II. Refer to BL-27, "
DATA MONI-
TOR" .
When key is inserted to ignition key cylinder:
When key is removed from ignition key cylinder:
Without CONSULT-II
Check voltage between BCM connector M18 terminal 37 and
ground.
OK or NG
OK >> Key switch (insert) circuit is OK.
NG >> GO TO 2.
2. CHECK KEY SWITCH (INSERT)
1. Turn ignition switch OFF.
2. Disconnect key switch and key lock solenoid connector.
3. Check continuity between key switch and key lock solenoid terminals 3, 4.
OK or NG
OK >> Repair or replace harness.
NG >> Replace key switch. KEY ON SW
: ON
KEY ON SW : OFF
LIIA0169E
ConnectorTerminals
ConditionVoltage (V)
(+) (– )
M18 37 Ground Key is inserted. Battery voltage
Key is removed. 0
LIIA0567E
TerminalsCondition Continuity
3 – 4 Key is inserted.
Yes
Key is removed. No
LIIA1044E
Page 844 of 3383
REMOTE KEYLESS ENTRY SYSTEMBL-63
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
Door Switch CheckEIS0062Q
1. CHECK DOOR SWITCHES INPUT SIGNAL
With CONSULT-II
Check door switches ("DOOR SW-DR", "DOOR SW-AS", "DOOR SW-RL", "DOOR SW-RR", "BACK DOOR
SW") in DATA MONITOR mode with CONSULT –II.Refer to BL-27, "
DATA MONITOR" .
When doors are open:
When doors are closed:
Without CONSULT-II
Check voltage between BCM connector M18 or M19 terminals 12,
13, 43, 47, 48 and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2. DOOR SW-DR : ON
DOOR SW-AS : ON
DOOR SW-RL : ON
DOOR SW-RR : ON
BACK DOOR SW : ON
DOOR SW-DR : OFF
DOOR SW-AS : OFF
DOOR SW-RL : OFF
DOOR SW-RR : OFF
BACK DOOR SW : OFF
LIIA0665E
Connector Item
Terminals
ConditionVoltage (V)
(Approx.)
(+) ( –)
M19 Back door
latch (door
ajar switch) 43
Ground Open
↓
Closed 0
↓
Battery voltage
Front door
switch LH 47
Rear door switch LH 48
M18 Front door
switch RH 12
Rear door
switch RH 13
LIIA1041E
Page 846 of 3383
REMOTE KEYLESS ENTRY SYSTEMBL-65
C
DE
F
G H
J
K L
M A
B
BL
Revision: November 2009 2006 QX56
4. CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Keyfob Battery and Function CheckEIS00604
1. CHECK KEYFOB BATTERY
Remove battery and measure voltage across battery positive and negative terminals, (+) and ( −).
NOTE:
Keyfob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery. 8 - Ground
: Continuity should exist.
LIIA0828E
Voltage: 2.5V - 3.0V
SEL237W
Page 849 of 3383
BL-68
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
ACC Power CheckEIS00606
1. CHECK ACC POWER
With CONSULT-II
Check "ACC ON SW" in DATA MONITOR mode with CONSULT –II. Refer to BL-27, "
DATA MONITOR" .
Without CONSULT-II
Check voltage between BCM connector M18 terminal 11 and
ground.
OK or NG
OK >> ACC power circuit is OK.
NG >> Check the following:
10A fuse [No. 4, located in fuse block (J/B)]
Harness for open or short.
IPDM E/R Operation CheckEIS00607
1. CHECK IPDM E/R INPUT VOLTAGE
Check voltage between IPDM E/R connector E122 terminal 45 and
ground.
OK or NG
OK >> Replace IPDM E/R.
NG >> GO TO 2.
Monitor Item Condition
ACC ON SW Ignition switch position ACC : ON
Ignition switch position OFF : OFF
PIIA3367E
ConnectorTerminals
ConditionVoltage (V)
(Approx.)
(+) ( –)
M18 11 Ground ACC
Battery voltage
OFF 0
PIIA7002E
ConnectorTerminals
Voltage (V)
(Approx.)
(+) (– )
E122 45 Ground Battery voltage
LIIA1053E
Page 855 of 3383
BL-74
REMOTE KEYLESS ENTRY SYSTEM
Revision: November 20092006 QX56
NOTE:
If a keyfob is lost, the ID code of the lost keyfob must be erased to prevent unauthorized use. A specific ID
code can be erased with CONSULT-II. However, when the ID code of a lost keyfob is not known, all con-
troller ID codes should be erased. After all ID codes are erased, the ID codes of all remaining and/or new
keyfobs must be re-registered.
To erase all ID codes in memory, register one ID code (keyfob) five times. After all ID codes are erased,
the ID codes of all remaining and/or new keyfobs must be re-registered.
When registering an additional keyfob, the existing ID codes in memory may or may not be erased. If five
ID codes are stored in memory, when an additional code is registered, only the oldest code is erased. If
less than five ID codes are stored in memory, when an additional ID code is registered, the new ID code is
added and no ID codes are erased.
If you need to activate more than two additional new keyfobs, repeat the procedure “Additional ID code
entry ” for each new keyfob.
Entry of maximum five ID codes is allowed. When more than five ID codes are entered, the oldest ID code
will be erased.
Even if same ID code that is already in the memory is input, the same ID code can be entered. The code
is counted as an additional code.
Keyfob Battery ReplacementEIS0060D
LIIA1514E