blower INFINITI QX56 2006 Factory Owner's Guide
Page 505 of 3383
ATC-104
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
Trouble Diagnosis Procedure For Rear Blower Motor (1 - 4 Speed)
SYMPTOM:
Rear blower motor does not rotate when rear blower control dial (front) is set at 1 - 4 speed.
Inspection Flow
*1 .ATC-60, "Operational Check
(Rear)"
*2ATC-104, "Trouble Diagnosis Proce-
dure For Rear Blower Motor (1 - 4
Speed)"
*3AT C - 3 9 , "SYMPTOM TABLE"
WJIA1058E
Page 506 of 3383
TROUBLE DIAGNOSISATC-105
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
1. DIAGNOSTIC PROCEDURE
Blower motor rotates normally at each speed.
OK or NG
OK >> Inspection End.
NG >> 1. Does not rotate at any speed, GO TO 2. 2. Does not rotate at 1 - 3 speed, GO TO 13.
3. Does not rotate at 4 speed, GO TO 18.
2. CHECK FUSES
Check 15A fuses [Nos. 10 and 11, located in the fuse block (J/B)]. Refer to PG-76, "
FUSE BLOCK-JUNCTION
BOX (J/B)" .
OK or NG
OK >> GO TO 3.
NG >> GO TO 8.
3. CHECK REAR BLOWER MOTOR POWER SUPPLY
1. Turn ignition switch OFF.
2. Disconnect rear blower motor connector.
3. Select any rear blower speed except OFF.
4. Turn ignition switch ON.
5. Check voltage between rear blower motor harness connector B134 terminal 2 and ground.
OK or NG
OK >> GO TO 11.
NG >> GO TO 4.
4. CHECK REAR BLOWER MOTOR RELAY
Turn ignition switch OFF.
Refer to AT C - 11 0 , "
Rear Blower Motor Relay" .
OK or NG
OK >> GO TO 5.
NG >> Replace rear blower motor relay.
5. CHECK REAR BLOWER MOTOR POWER FROM RELAY TO REAR BLOWER MOTOR
1. Reconnect rear blower motor connector.
2. Disconnect rear blower motor relay J-1.
3. Turn ignition switch ON.
4. Set rear blower switch (front) to any position except OFF, REAR, or 4 - speed.
5. Momentarily (no more than 4 seconds), connect a jumper wire between rear blower motor relay connector J-1 (harness side)
terminals 3 and 5.
OK or NG
OK >> GO TO 6.
NG >> GO TO 10. 2 - Ground
: Battery voltage.
WJIA0596E
Rear blower motor should rotate.WJIA0972E
Page 507 of 3383
ATC-106
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
6. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M39.
3. Turn ignition switch ON.
4. Set rear blower switch (front) to any position except OFF, REAR, or 4 - speed.
5. Check voltage between fuse block (J/B) harness connector M39 terminal 3Q and ground.
OK or NG
OK >> GO TO 7.
NG >> GO TO 20.
7. CHECK REAR BLOWER MOTOR RELAY (COIL SIDE) GROUND CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M3.
3. Check continuity between fuse block (J/B) harness connector M3 terminal 7N and ground.
OK or NG
OK >> Replace fuse block (J/B).
NG >> Repair harness or connector.
8. REPLACE FUSE
Refer to PG-76, "
FUSE BLOCK-JUNCTION BOX (J/B)"
Fuse should not open when rear blower motor is activated.
OK or NG
OK >> Inspection End.
NG >> GO TO 9.
9. CHECK REAR BLOWER MOTOR POWER SUPPLY CIRCUIT FOR SHORT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) connector M3 and rear blower motor connector.
3. Check continuity between rear blower motor harness connector B134 terminal 2 and ground.
OK or NG
OK >> Check rear blower motor. Refer to ATC-100, "Front
Blower Motor" .
NG >> Repair harness or connector. 3Q - Ground : Battery voltage.
LJIA0101E
7N - Ground
: Continuity should exist.
WJIA0597E
2 - Ground: Continuity should not exist.
WJIA0598E
Page 508 of 3383
TROUBLE DIAGNOSISATC-107
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
10. CHECK REAR BLOWER MOTOR RELAY (SWITCH SIDE) POWER SUPPLY CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect fuse block (J/B) and rear blower motor connectors.
3. Check continuity between fuse block (J/B) harness connector M3 terminal 3N and 8N and rear blower motor harness connec-
tor B134 terminal 2.
OK or NG
OK >> GO TO 20.
NG >> Repair harness or connector.
11 . CHECK REAR BLOWER MOTOR
Check rear blower motor. Refer to AT C - 111 , "
Rear Blower Motor" .
OK or NG
OK >> GO TO 12.
NG >> Replace rear blower motor. refer to ATC-150, "
REAR BLOWER MOTOR"
12. CHECK REAR BLOWER SWITCH (FRONT)
Refer to AT C - 11 0 , "
Rear Blower Switch (Front)" .
OK or NG
OK >> GO TO 15.
NG >> Replace rear blower switch (front). Refer to ATC-144, "
FRONT AIR CONTROL"
13. CHECK REAR BLOWER MOTOR RESISTOR
Refer to AT C - 111 , "
Rear Blower Motor Resistor" .
OK or NG
OK >> GO TO 14.
NG >> Replace rear blower motor resistor. Refer to ATC-165, "
REAR BLOWER MOTOR RESISTOR"
14. CHECK REAR BLOWER SWITCH (FRONT) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect rear blower switch (front) M52.
3. Turn ignition switch ON.
4. Reconnect rear blower motor resistor harness connector B133.
5. Check voltage between each rear blower switch (front) connec- tor M52 terminals 3, 7, and 8, and ground.
OK or NG
OK >> GO TO 17.
NG >> GO TO 16. 3N, 8N - 2
: Continuity should exist.
WJIA0599E
Terminal No.
Voltage
(+) (-)
3 Ground Approx. 12V
7
8
LJIA0108E
Page 509 of 3383
ATC-108
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
15. CHECK REAR BLOWER MOTOR GROUND CIRCUIT TO REAR BLOWER MOTOR RESISTOR
1. Turn ignition switch OFF.
2. Disconnect rear blower motor and rear blower motor resistor connectors.
3. Check continuity between rear blower motor connector B134 (A) terminal 1 and rear blower motor resistor harness connector
B133 (B) terminal 3.
4. Check continuity between rear blower motor connector B134 (A) terminal 1 and ground.
OK or NG
OK >> GO TO 16.
NG >> Repair harness or connector.
16. CHECK REAR BLOWER SWITCH (FRONT) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect rear blower motor resistor connector.
3. Check continuity between rear blower switch (front) connector M52 (A) terminals 3, 7, and 8, and rear blower motor resistor
connector B133 (B) terminals 1, 4, and 2.
OK or NG
OK >> Inspection End.
NG >> Repair harness or connector.
17. CHECK REAR BLOWER SWITCH (FRONT) CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect rear blower switch (rear) connectors.
3. Check continuity between rear blower switch (front) connector M52 terminals 3, 5, 7, and 8, and rear blower switch (rear) con-
nector R208 terminals 9, 6, 8, and 7.
OK or NG
OK >> GO TO 18.
NG >> Repair harness or connector. 1 - 3
: Continuity should exist.
1 - Ground : Continuity should not exist.
WJIA1916E
Terminal No.
Continuity
Rear blower switch (front)
(A) Rear blower motor resistor
(B)
31 Ye s
74
82
WJIA1651E
Terminal No.
Continuity
Rear blower switch (front) Rear blower switch (rear)
39
Ye s
56
78
87
LJIA0110E
Page 510 of 3383
TROUBLE DIAGNOSISATC-109
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
18. CHECK REAR BLOWER SWITCH (FRONT)
Refer to AT C - 11 0 , "
Rear Blower Switch (Front)" .
OK or NG
OK >> GO TO 19.
NG >> Replace rear blower switch (front). Refer to ATC-144, "
FRONT AIR CONTROL"
19. CHECK REAR BLOWER SWITCH (REAR)
Refer to AT C - 11 0 , "
Rear Blower Switch (Rear)" .
OK or NG
OK >> Inspection End.
NG >> Replace rear blower switch (rear). Refer to ATC-144, "
REAR AIR CONTROL"
20. CHECK CIRCUIT BETWEEN FRONT AIR CONTROL AND FUSE BLOCK (J/B) [REAR BLOWER
MOTOR RELAY (COIL SIDE) POWER]
1. Disconnect front air control and fuse block (J/B) connectors M39.
2. Check continuity between front air control harness connector M50 terminal 38 and fuse block (J/B) connector M39 terminal
3Q.
OK or NG
OK >> Replace front air control. Refer to ATC-144, "FRONT
AIR CONTROL" .
NG >> Repair harness or connector. Continuity should exist.LJIA0111E
Page 511 of 3383
ATC-110
TROUBLE DIAGNOSIS
Revision: November 20092006 QX56
COMPONENT INSPECTION
Rear Blower Motor Relay
Check circuit continuity between terminals by supplying 12 volts and
ground to coil side terminals of relays.
Rear Blower Switch (Rear)
Check continuity between terminals at each switch position.
Rear Blower Switch (Front)
Check continuity between terminals at each switch position.
WJIA0973E
LJIA0113E
LJIA0114E
Page 512 of 3383
TROUBLE DIAGNOSISATC-111
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
Rear Blower Motor
Check that there are no foreign particles inside the intake unit.
Apply 12 volts to terminal 2 and ground to terminal 1 and ensure that
the blower motor rotates freely and quietly.
Rear Blower Motor Resistor
Check continuity between terminals. There will be resistance, but
there should not be an open or short between any two terminals.
WJIA1508E
WJIA1269E
Page 514 of 3383
TROUBLE DIAGNOSISATC-113
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
SYSTEM DESCRIPTION
Component Parts
Rear air control system components are:
Front air control
Rear air control
Air mix door motor (rear)
Rear blower motor relay
Rear blower motor resistor
Rear blower motor
System Operation
Rear Air Control
When the rear blower switch (front) (integral to the front air control) is in the REAR position the rear blower
motor speeds and the rear temperature and mode are controlled by the rear blower switch (rear) and the rear
temperature switch (rear) (both integral to the rear air control).
DIAGNOSTIC PROCEDURE FOR REAR AIR CONTROL
SYMPTOM:
Blower motor operation is malfunctioning. Refer to ATC-101, "Rear Blower Motor Circuit" .
Temperature and mode operation is malfunctioning.
1. CHECK OPERATION FROM FRONT AIR CONTROL
Does rear temperature and mode operate normally from front air control?
YES or NO
YES >> GO TO 2.
NO >> Refer to AT C - 7 9 , "
DIAGNOSTIC PROCEDURE FOR AIR MIX DOOR MOTOR (REAR)" .
WJIA1132E
Page 520 of 3383
TROUBLE DIAGNOSISATC-119
C
DE
F
G H
I
K L
M A
B
AT C
Revision: November 2009 2006 QX56
9. CHECK BCM INPUT (FAN ON) SIGNAL
Check FAN ON/OFF signal. Refer to AT C - 3 4 , "
CONSULT-II Function
(HVAC)" .
OK or NG
OK >> GO TO 12.
NG >> GO TO 10.
10. CHECK CIRCUIT CONTINUITY BETWEEN BCM AND FRONT AIR CONTROL
1. Turn ignition switch OFF.
2. Disconnect BCM connector and front air control connector.
3. Check continuity between BCM harness connector M18 terminal 28 and front air control harness connector M49 terminal 10.
OK or NG
OK >> GO TO 11.
NG >> Repair harness or connector.
11 . CHECK VOLTAGE FOR FRONT AIR CONTROL (FAN ON SIGNAL)
1. Reconnect BCM connector and front air control connector.
2. Turn ignition switch ON.
3. Check voltage between front air control harness connector M49 terminal 10 and ground.
OK or NG
OK >> GO TO 12.
NG-1 >> If the voltage is approx. 5V when blower motor is ON, replace front air control. Refer to ATC-144,
"FRONT AIR CONTROL" .
NG-2 >> If the voltage is approx. 0V when blower motor is OFF, replace BCM. Refer to BCS-20, "
BCM" .
FRONT BLOWER CONTROL
DIAL ON
: FAN ON SIG ON
FRONT BLOWER CONTROL
DIAL OFF : FAN ON SIG OFF
WJIA0469E
28 - 10
Continuity should exist.
WJIA0450E
Terminals
Condition Voltage
(+)
(-)
Front air con-
trol connector Terminal No.
M49 10GroundA/C switch: ON
Blower motor
operates
Approx. 0V
A/C switch: OFF Approx. 5V
WJIA0451E