turn signal INFINITI QX56 2006 Factory Service Manual

Page 2525 of 3383

LT-118
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: November 20092006 QX56
Terminals and Reference Values for IPDM E/REKS00BAQ
How to Proceed With Trouble DiagnosisEKS00BAR
1. Confirm the symptom or customer complaint.
2. Understand operation description and function description. Refer to LT- 111 , "
System Description" .
3. Carry out the Preliminary Check. Refer to LT- 11 8 , "
Preliminary Check" .
4. Check symptom and repair or replace the cause of malfunction.
5. Do the parking, license and tail lamps operate normally? If YES: GO TO 6. If NO: GO TO 4.
6. Inspection End.
Preliminary CheckEKS00BAS
CHECK POWER SUPPLY AND GROUND CIRCUIT
1. CHECK FUSES OR FUSIBLE LINK
Check for blown fuses or fusible link.
Refer to LT- 11 4 , "
Wiring Diagram — TAIL/L —" .
OK or NG
OK >> GO TO 2.
NG >> If fuse or fusible link is blown, be sure to eliminate cause of malfunction before installing new fuse or fusible link. Refer to PG-4, "
POWER SUPPLY ROUTING CIRCUIT" .
35 O/B Combination switch output 2
ONLighting, turn, wiper OFF
Wiper dial position 4
36 R/W Combination switch output 1
38 W/L Ignition switch (ON) ON— Battery voltage
39 L CAN-H ———
40 P CAN-L ———
67 B Ground ON— 0V
70 W/B Battery power supply (fusible link) OFF —Battery voltage
Terminal
No. Wire
color Signal name Measuring condition
Reference value
(Approx.)
Ignition
switch Operation or condition
SKIA5292E
Te r m i n a l
No. Wire
color Signal name Measuring condition
Reference value
(Approx.)
Ignition
switch Operation or condition
38 B Ground ON— 0V
39 L CAN-H —— —
40 P CAN-L —— —
57 R/L Parking, license, and tail
lamp ON
Lighting switch
1ST position OFF
0V
ON Battery voltage
59 B Ground ON— 0V
Unit Power sourceFuse and fusible link No.
BCM Battery
f
Ignition switch ON or START position 59
IPDM E/R Battery
53
Battery (Tail lamps ON) 37

Page 2527 of 3383

LT-120
PARKING, LICENSE PLATE AND TAIL LAMPS
Revision: November 20092006 QX56
Parking, License Plate and/or Tail Lamps Do Not IlluminateEKS00BAU
1. CHECK COMBINATION SWITCH INPUT SIGNAL
With CONSULT-II
Select "BCM" on CONSULT-II. With "HEAD LAMP" data monitor,
make sure "LIGHT SW 1ST" turns ON-OFF linked with operation of
lighting switch.
Without CONSULT-II
Refer to LT- 1 0 3 , "
Combination Switch Inspection" .
OK or NG
OK >> GO TO 2.
NG >> Check lighting switch. Refer to LT- 1 0 3 , "
Combination
Switch Inspection" .
2. ACTIVE TEST
With CONSULT-II
1. Select "IPDM E/R" on CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
2. Select "EXTERNAL LAMPS" on "SELECT TEST ITEM" screen.
3. Touch "TAIL" on "ACTIVE TEST" screen.
4. Make sure parking, license plate and tail lamp operation.
Without CONSULT-II
1. Start auto active test. Refer to PG-24, "
Auto Active Test" .
2. Make sure parking, license plate and tail lamp operation.
OK or NG
OK >> GO TO 3.
NG >> GO TO 4.
3. CHECK IPDM E/R
1. Select "IPDM E/R" on CONSULT-II, and select "DATA MONI- TOR" on "SELECT DIAG MODE" screen.
2. Make sure "TAIL&CLR REQ" turns ON when lighting switch is in 1ST position.
OK or NG
OK >> Replace IPDM E/R. Refer to PG-30, "Removal and
Installation of IPDM E/R" .
NG >> Replace BCM. Refer to BCS-20, "
BCM" .
When lighting switch is in
1ST position
: LIGHT SW 1ST ON
SKIA5956E
Parking, license plate and tail lamp should operate
Parking, license plate and tail lamp should operate
WKIA1438E
When lighting switch is in
1ST position: TAIL&CLR REQ ON
SKIA5958E

Page 2528 of 3383

PARKING, LICENSE PLATE AND TAIL LAMPSLT-121
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
4. CHECK INPUT SIGNAL
With CONSULT-II
1. Turn ignition switch OFF.
2. Disconnect front combination lamp, license plate lamp and rear combination lamp connectors.
3. Turn ignition switch ON.
4. Select "IPDM E/R" on CONSULT-II, and select "ACTIVE TEST" on "SELECT DIAG MODE" screen.
5. Select "TAIL LAMP" on "SELECT TEST ITEM" screen.
6. Touch "ON" on "ACTIVE TEST" screen.
7. When tail lamp is operating, check voltage between front combination lamp, license plate lamp, rear com- bination lamp harness connector and ground.
Without CONSULT-II
1. Start auto active test. Refer to PG-24, "
Auto Active Test" .
2. When tail lamp is operating, check voltage between front combination lamp, license plate lamp, rear com- bination lamp connector and ground.
OK or NG
OK >> GO TO 6.
NG >> GO TO 5.
Front combination lamp (+) (– ) Voltage
Connector Terminal
RH E107 3Ground Battery voltage
LH E11
WKIA1900E
License plate lamps (+) (– ) Voltage
Connector Terminal
D703 1Ground Battery voltage
WKIA4613E
Rear combination lamp (+)
(– ) Voltage
Connector Terminal
RH B130 3Ground Battery voltage
LH B70
WKIA1901E

Page 2532 of 3383

REAR COMBINATION LAMPLT-125
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
REAR COMBINATION LAMPPFP:26554
Bulb ReplacementEKS00BAZ
SIDE MARKER LAMP (REAR)
Side marker lamps (rear) are LED's and are not serviceable separately. Replace rear combination lamp. Refer
to LT- 1 2 5 , "
REAR COMBINATION LAMP" .
TAIL LAMP
Tail lamps are LED's and are not serviceable separately. Replace rear combination lamp. Refer to LT- 1 2 5 ,
"Removal and Installation" .
TURN SIGNAL
Removal
1. Remove rear combination lamp bolts.
2. Pull rear combination lamp to remove from the vehicle.
3. Turn bulb socket counterclockwise and remove turn signal
socket.
4. Remove turn signal lamp bulb.
STOP LAMP
Stop lamps are LED's and are not serviceable separately. Replace rear combination lamp. Refer to LT- 1 2 5 ,
"Removal and Installation" .
INSTALLATION
Installation is in the reverse order of removal.
Removal and InstallationEKS00BB0
REAR COMBINATION LAMP
Removal
1. Remove rear combination lamp mounting bolts.
2. Pull rear combination lamp to remove from the vehicle.
3. Disconnect rear combination lamp connectors.
Installation
Installation is in the reverse order of removal.
WKIA1393E
WKIA1393E

Page 2534 of 3383

TRAILER TOWLT-127
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
through IPDM E/R terminal 61
to trailer tow relay 1 terminal 3, and
through 20A fuse (No. 53, located in the IPDM E/R)
to CPU (central processing unit) of the IPDM E/R, and
through 30A fusible link (letter j , located in the fuse and fusible link box)
to trailer tow relay 2 terminals 3 and 6, and
through 40A fusible link (letter k , located in the fuse and fusible link box)
to electric brake (pre-wiring) terminal 5.
With the ignition switch in the ON or START position, power is supplied
to ignition relay, located in the IPDM E/R, and
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38, and
through 10A fuse (No. 51, located in the IPDM E/R)
to trailer tow relay 2 terminal 1.
Ground is supplied
to BCM terminal 67
to electric brake (pre-wiring) terminal 1, and
through grounds M57, M61 and M79, and
to IPDM E/R terminals 38 and 59
to trailer tow relay 1 terminal 2
to trailer tow relay 2 terminal 2, and
to trailer connector terminal 2
to trailer turn relay LH and RH terminal 2
through grounds E9, E15 and E24.
TRAILER TAIL LAMP OPERATION
The trailer tail lamps are controlled by the trailer tow relay 1.
With the lighting switch in the parking and tail lamp ON (1ST) position, AUTO position (and the auto light sys-
tem is activated) or headlamp ON (2ND) position, power is supplied
through the tail lamp relay, located in the IPDM E/R
through 10A fuse (No. 36, located in the IPDM E/R)
through IPDM E/R terminal 49
to trailer tow relay 1 terminal 1.
When energized, trailer tow relay 1 supplies tail lamp power to trailer connector terminal 6.
TRAILER BRAKE, TURN SIGNAL AND HAZARD LAMP OPERATION
The trailer brake, turn signal and hazard lamps are controlled by the BCM through trailer turn relays (LH and
RH). When the brake pedal is depressed, the BCM receives stop lamp switch signal through CAN communi-
cation. If the brake pedal is depressed or either turn signal or the hazard lamps are turned on, the BCM sup-
plies voltage to the trailer turn relays (LH and RH) to make them cycle on and off.
Trailer turn relay LH output is supplied
through BCM terminal 52
to trailer turn relay LH terminal 1.
Trailer turn relay RH output is supplied
through BCM terminal 51
to trailer turn relay RH terminal 1.
Left trailer brake, turn signal and hazard lamp output is supplied
through trailer turn relay LH terminal 3
to trailer connector terminal 1.
Right trailer brake, turn signal and hazard lamp output is supplied
through trailer turn relay RH terminal 3

Page 2542 of 3383

INTERIOR ROOM LAMPLT-135
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
System DescriptionEKS00BB6
When room lamp and personal lamp switch is in DOOR position, room lamp and personal lamp ON/OFF is
controlled by timer according to signals from switches including key switch and key lock solenoid, front door
switch LH, unlock signal from keyfob, door lock and unlock switch, front door lock assembly LH (key cylinder
switch), ignition switch, and glass hatch ajar switch.
When room lamp and personal lamp turns ON, there is a gradual brightening over 1 second. When room lamp
and personal lamp turns OFF, there is a gradual dimming over 1 second.
The room lamp and personal lamp timer is controlled by the BCM (body control module).
Room lamp and personal lamp timer control settings can be changed with CONSULT-II.
Ignition keyhole illumination turns ON when front door LH is opened (door switch ON) or key is removed from
key cylinder. Illumination turns OFF when front door LH is closed (door switch OFF).
Step and foot lamps turn ON when front or rear doors are opened (door switch ON). Lamps turn OFF when
front and rear doors are closed (all door switches OFF).
POWER SUPPLY AND GROUND
Power is supplied at all times
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3, and
through 15A fuse [No. 22, located in the fuse block (J/B)]
to BCM terminal 57, and
through 50A fusible link (letter f , located in the fuse and fusible link box)
to BCM terminal 70.
When the key is inserted in key switch and key lock solenoid, power is supplied
through the key switch and key lock solenoid terminal 4
to BCM terminal 37.
With the ignition switch in the ON or START position, power is supplied
through 10A fuse (No. 59, located in the fuse and relay box)
to BCM terminal 38.
Ground is supplied
to BCM terminal 67
through grounds M57, M61 and M79.
When the front door LH is opened, ground is supplied
to BCM terminal 47
through case ground of front door switch LH.
When the front door RH is opened, ground is supplied
to BCM terminal 12
through case ground of front door switch RH.
When the rear door LH is opened, ground is supplied
to BCM terminal 48
through case ground of rear door switch LH.
When the rear door RH is opened, ground is supplied
to BCM terminal 13
through case ground of rear door switch RH.
When the liftgate is opened, ground is supplied
to BCM terminal 43
through back door latch (door ajar switch) terminal 7
through back door latch (door ajar switch) terminal 8
through grounds B7 and B19.
When the glass hatch is opened, ground is supplied
to BCM terminal 42
through case ground of glass hatch ajar switch.

Page 2544 of 3383

INTERIOR ROOM LAMPLT-137
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
through 10A fuse [No. 19, located in the fuse block (J/B)]
to key switch and key lock solenoid terminal 3.
Key is removed from ignition key cylinder (key switch OFF), power will not be supplied to BCM terminal 37.
Serial data is supplied
to BCM terminal 22
through main power window and door lock/unlock switch terminal 14.
At the time that front door LH is opened, BCM detects that front door LH is unlocked. It determines that interior
room lamp and map lamp timer operation conditions are met, and turns the interior room lamps ON for 30 sec-
onds.
Key is in ignition key cylinder (key switch ON), power is supplied
through key switch and key lock solenoid terminal 4
to BCM terminal 37.
When key is removed from key switch and key lock solenoid (key switch OFF), power supply to BCM terminal
37 is terminated. BCM detects that key has been removed, determines that interior room lamp and map lamp
timer conditions are met, and turns the interior room lamps ON for 30 seconds.
When front door LH opens → closes, and the key is not inserted in the key switch and key lock solenoid (key
switch OFF), BCM terminal 47 changes between 0V (door open) → 12V (door closed). The BCM determines
that conditions for interior room lamp operation are met and turns the interior room lamp ON for 30 seconds.
Timer control is canceled under the following conditions.
Front door LH is locked [when locked by keyfob, main power window and door lock/unlock switch, or front
door lock assembly LH (key cylinder switch)]
Front door LH is opened (front door switch LH turns ON)
Ignition switch ON.
INTERIOR LAMP BATTERY SAVER CONTROL
If interior lamp is left “ON”, it will not be turned off even when door is closed.
BCM turns off interior lamp automatically to save battery 30 minutes after ignition switch is turned off.
BCM controls interior lamps listed below:
Va n i t y l a m p
Room/map lamp
Cargo lamp
Personal lamp
St ep la m ps
Puddle lamps
Foot lamps
Ignition keyhole illumination
After lamps turn OFF by the battery saver system, the lamps illuminate again when
signal received from keyfob, or main power window and door lock/unlock switch or front door lock assem-
bly LH (key cylinder switch) is locked or unlocked
door is opened or closed
key is removed from ignition key cylinder (key switch OFF) or inserted in ignition key cylinder (key switch
ON).
Interior lamp battery saver control period can be changed by the function setting of CONSULT-II.

Page 2554 of 3383

INTERIOR ROOM LAMPLT-147
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
Terminals and Reference Values for BCMEKS00BB9
Terminal
No. Wire
color Signal name Measuring condition
Reference value
(Approx.)
Ignition
switch Operation or condition
1BR/W Ignition keyhole illumi-
nation signal
OFFDoor is locked. (SW OFF)
Battery voltage
Door is unlocked. (SW ON) 0V
12 R/L Front door switch RH
signal
OFFFront door
switch RH ON (open)
0V
OFF (closed) Battery voltage
13 GR Rear door switch RH
signal
OFFRear door
switch RH ON (open)
0V
OFF (closed) Battery voltage
22 W/V Bus ——
37 B/R Key-in switch detection
signal OFFVehicle key is removed.
0V
Vehicle key is inserted. Battery voltage
38 W/L Ignition power supply ON —Battery voltage
39 L CAN-H —— —
40 P CAN-L —— —
42 GR Glass hatch ajar switch
signal OFFGlass hatch
ajar switch ON (open)
0V
OFF (closed) Battery voltage
43 R/B Back door latch (door
ajar switch) signal
OFFBack door
latch (door
ajar switch) ON (open)
0V
OFF (closed) Battery voltage
47 SB Front door switch LH
signal
OFFFront door
switch LH ON (open)
0V
OFF (closed) Battery voltage
48 R/Y Rear door switch LH
signal
OFFRear door
switch LH ON (open)
0V
OFF (closed) Battery voltage
49 R Luggage lamp output OFF Any door is open (ON)
0V
All doors are closed (OFF) Battery voltage
56 R/G Battery saver output
signal OFF
30 minutes after ignition switch is
turned to OFF 0V
ON — Battery voltage
57 Y/R Battery power supply OFF —Battery voltage
62 R/W Step lamp signal OFFAny door is open (ON)
0V
All doors are closed (OFF) Battery voltage
63 L Interior room/map lamp
signal OFFEach interior
lamp switch
in DOOR
position Any
door
switch ON
(open) 0V
OFF
(closed) Battery voltage
67 B Ground ON— 0V
70 W/B Battery power supply OFF —Battery voltage
PIIA2344J

Page 2556 of 3383

INTERIOR ROOM LAMPLT-149
C
DE
F
G H
I
J
L
M A
B
LT
Revision: November 2009 2006 QX56
CONSULT-II Function (BCM)EKS00BBC
CONSULT-II can display each diagnostic item using the diagnostic test modes shown following.
CONSULT-II OPERATION
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carries out CAN communication.
1. With the ignition switch OFF, connect CONSULT-II and CON-
SULT-II CONVERTER to the data link connector, then turn igni-
tion switch ON.
2. Touch "START (NISSAN BASED VHCL)".
3. Touch "BCM" on "SELECT SYSTEM" screen. If "BCM" is not indicated, go to GI-40, "
CONSULT-II Data Link
Connector (DLC) Circuit" .
BCM diagnostic
test item Diagnostic mode
Description
Inspection by part WORK SUPPORT
Supports inspections and adjustments. Commands are transmitted to the BCM
for setting the status suitable for required operation, input/output signals are
received from the BCM and received data is displayed.
DATA MONITOR Displays BCM input/output data in real time. ACTIVE TEST Operation of electrical loads can be checked by sending drive signal to them.
SELF-DIAG RESULTS Displays BCM self-diagnosis results.
CAN DIAG SUPPORT MNTR The result of transmit/receive diagnosis of CAN communication can be read. ECU PART NUMBER BCM part number can be read.CONFIGURATION Performs BCM configuration read/write functions.
BBIA0369E
BCIA0029E
BCIA0030E

Page 2557 of 3383

LT-150
INTERIOR ROOM LAMP
Revision: November 20092006 QX56
4. Touch "INT LAMP" on "SELECT TEST ITEM" screen.
WORK SUPPORT
Operation Procedure
1. Touch "INT LAMP" on "SELECT TEST ITEM" screen.
2. Touch "WORK SUPPORT" on "SELECT DIAG MODE" screen.
3. Touch "SET I/L D-UNLCK INTCON" on "SELECT WORK ITEM" screen.
4. Touch "START".
5. Touch "CHANGE SETT".
6. The setting will be changed and "CUSTOMIZING COMPLETED" will be displayed.
7. Touch "END".
Display Item List
Reference between "MODE" and "TIME" for "TURN ON/OFF".
DATA MONITOR
Operation Procedure
1. Touch "INT LAMP" on "SELECT TEST ITEM" screen.
2. Touch "DATA MONITOR" on "SELECT DIAG MODE" screen.
3. Touch either "ALL SIGNALS" or "SELECTION FROM MENU" on "SELECT MONITOR ITEM" screen.
4. Touch "START".
5. When "SELECTION FROM MENU" is selected, touch items to be monitored. When "ALL SIGNALS" is
selected, all the items will be monitored.
6. Touch "RECORD" while monitoring, then the status of the monitored item can be recorded. To stop recording, touch "STOP".
PKIA5226E
Item Description CONSULT-II
SET I/L D-UNLCK INTCON The 30 seconds operating function of the interior room lamps and the
ignition keyhole illumination can be selected when front door LH is
released (unlocked). ON/OFF
ROOM LAMP ON TIME SET The time in order to escalate illumination can be adjusted when the
interior room lamps and the ignition keyhole illumination is turned on. MODE 1 - 7
ROOM LAMP OFF TIME SET The time in order to diminish illumination can be adjusted when the
interior room lamps and the ignition keyhole illumination is turned off. MODE 1 - 7
MODE 1 2 3 4 5 6 7
Time (sec.) 0.5 1 2 3 4 5 0
All signals Monitors all the signals.
Selection from menu Selects and monitors the individual signal.

Page:   < prev 1-10 ... 371-380 381-390 391-400 401-410 411-420 421-430 431-440 441-450 451-460 ... 530 next >