200 INFINITI QX56 2009 Factory Service Manual

Page 3254 of 4171

SE-22
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
ECU DIAGNOSIS
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
Reference ValueINFOID:0000000003775450
TERMINAL LAYOUT
PHYSICAL VALUES
ALJIA0277ZZ
Te r m i n a l N o .Wire
color Description
ConditionVoltage (V)
(Approx.)
+ - Signal nameInput/
Output
1 Ground Y/R Battery Input— Battery voltage
3Ground LG 40% seat switch signal
(down) OutputPush either third row power fold-
ing seat switch passenger (down) 0
Third row power folding seat switch passenger released Battery voltage
4Ground V 60% seat switch signal
(down) OutputPush either third row power fold-
ing seat switch driver (down) 0
Third row power folding seat switch driver released Battery voltage
7 Ground G/R Park signal InputA/T selector lever in P or N
Battery voltage
A/T selector lever not in P or N 0
8 Ground O/L Ignition signal InputIgnition switch ON or START
Battery voltage
Ignition switch OFF 0
9 Ground G/B 40% seat Hall signal Input —9V
10 Ground O/B 60% seat Hall signal Input —9V
11 Ground SB 40% seat switch signal (up) Output Push either third row power fold-
ing seat switch passenger (up) 0
Third row power folding seat switch passenger released Battery voltage
12 Ground O 60% seat switch signal (up) Output Push either third row power fold-
ing seat switch driver (up) 0
Third row power folding seat switch driver released Battery voltage
13 Ground W Battery Input— Battery voltage
14 Ground W Battery Input— Battery voltage
15 Ground Y/B Hall switch ground —— —
16 Ground B Switch ground —— —
17 Ground W/L 60% Seat motor Output— Battery voltage
18 Ground B Ground —— —
19 Ground R/W 60% Seat motor Output— Battery voltage
Revision: December 20092009 QX56

Page 3255 of 4171

THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-23
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
20 Ground G/W 40% Seat motor Output— Battery voltage
21 Ground B Ground —— —
22 Ground V 40% Seat motor Output— Battery voltage
Te r m i n a l N o .
Wire
color Description
ConditionVoltage (V)
(Approx.)
+ - Signal nameInput/
Output
Revision: December 20092009 QX56

Page 3256 of 4171

SE-24
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
Wiring Diagram
INFOID:0000000003775451
ABJWA0032GB
Revision: December 20092009 QX56

Page 3257 of 4171

THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-25
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
ABJIA0088GB
Revision: December 20092009 QX56

Page 3258 of 4171

SE-26
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
ABJIA0089GB
Revision: December 20092009 QX56

Page 3259 of 4171

THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-27
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
ABJIA0090GB
Revision: December 20092009 QX56

Page 3260 of 4171

SE-28
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
ABJIA0091GB
Revision: December 20092009 QX56

Page 3261 of 4171

THIRD ROW POWER FOLDING SEAT CONTROL UNITSE-29
< ECU DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
DTC IndexINFOID:0000000003775452
NOTE:
To initiate a chime code sequence cycle, turn the ignition switch ON and OFF 3 times within 5 seconds. The
first digit will chime, then a pause, followed by the sec ond digit. For example, a code 13 will have 1 chime, fol-
lowed by a pause, and then 3 chimes. The third row pow er folding seat control unit will clear all codes that
have been corrected after 255 ignition cycles.
ABJIA0092GB
Revision: December 20092009 QX56

Page 3262 of 4171

SE-30
< ECU DIAGNOSIS >
THIRD ROW POWER FOLDING SEAT CONTROL UNIT
Fail Safe
INFOID:0000000003775453
The third row power folding seat will not operate under the following conditions:
• Power supply to the third row power folding seat control unit falls below 9.0V
• One of the third row power foldi ng seat switches is stuck closed
• The A/T selector lever is not in PARK position and the ignition switch is ON
DTCMalfunction Service Procedure
11 LH seat has traveled past normal fold
down position 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor LH Hall signal and ground circuits. Refer to SE-36, "
Third Row Power
Folding Seat Stops Short of it's Fully Up or Down Posi-
tion".
3. Replace third row power folding seat motor LH. Refer to SE-56, "
Exploded View".
12
LH seat has traveled past normal fold up
position
13 LH seat actuation cycle has taken too
long and timed out 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor LH motor cir- cuits. Refer to SE-33, "
Only One Third Row Power Fold-
ing Seat Will Operate".
3. Replace third row power folding seat motor LH. Refer to SE-56, "
Exploded View".
14 Third row power folding seat control unit
NVRAM data for LH seat position has
been corrupted Replace third row power folding seat control unit. Refer to
SE-
59, "Power seat cross beam".
15 Power supply to thir
d row power folding
seat control unit has been interrupted
during LH seat fold up/down cycle 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Replace third row power folding seat control unit. Refer to SE-59, "
Power seat cross beam".
21 RH seat has traveled past normal fold
down position 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor RH Hall signal and ground circuits. Refer to SE-36, "
Third Row Power
Folding Seat Stops Short of it's Fully Up or Down Posi-
tion".
3. Replace third row power folding seat motor RH. Refer to SE-56, "
Exploded View".
22
RH seat has traveled past normal fold up
position
23 RH seat actuation cycle has taken too
long and timed out 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Check third row power folding seat motor RH motor cir- cuits. Refer to SE-33, "
Only One Third Row Power Fold-
ing Seat Will Operate".
3. Replace third row power folding seat motor RH. Refer to SE-56, "
Exploded View".
24 Third row power folding seat control unit
NVRAM data for RH seat position has
been corrupted Replace third row power folding seat control unit. Refer to
SE-
59, "Power seat cross beam".
25 Power supply to thir
d row power folding
seat control unit has been interrupted
during RH seat fold up/down cycle 1. Perform Preliminary Check. Refer to
SE-5, "
Preliminary
Check".
2. Replace third row power folding seat control unit. Refer
to SE-59, "
Power seat cross beam".
33 System normal or END of chime codes —
Revision: December 20092009 QX56

Page 3263 of 4171

THIRD ROW POWER FOLDING SEATSE-31
< SYMPTOM DIAGNOSIS >
C
DE
F
G H
I
K L
M A
B
SE
N
O P
SYMPTOM DIAGNOSIS
THIRD ROW POWER FOLDING SEAT
Symptom TableINFOID:0000000003775454
Symptom Reference
None of the third row power folding seats will operate with any switch. Refer to
SE-32, "
None of the Third Row Power Folding
Seats Will Operate With Any Third Row Power Folding
Seat Switch".
Only one third row power folding seat will operate. Refer to
SE-33, "
Only One Third Row Power Folding Seat
Will Operate".
Third row power folding seat will operate in only one direction. Refer to
SE-35, "
Third Row Power Folding Seat Will Oper-
ate in Only One Direction".
Third row power folding seat will stop short of its fully up or down position. Refer to
SE-36, "
Third Row Power Folding Seat Stops
Short of it's Fully Up or Down Position".
Third row power folding seat makes excessive noise while moving. Refer to
SE-37, "
Third Row Power Fold ing Seat Makes Ex-
cessive Noise While Moving".
Seats make squeak or rattle noise. Refer to SE-38, "
Work Flow".
Revision: December 20092009 QX56

Page:   < prev 1-10 ... 3211-3220 3221-3230 3231-3240 3241-3250 3251-3260 3261-3270 3271-3280 3281-3290 3291-3300 ... 4170 next >