GLASS HATCH SWITCHDLK-127
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
GLASS HATCH SWITCH
Diagnosis ProcedureINFOID:0000000005146999
Regarding Wiring Diagram information, refer to DLK-157, "Wiring Diagram — POWER DOOR LOCK SYS-
TEM —".
NOTE:
Repair any front door lock actuator RH malf unction before proceeding with this diagnosis.
1.CHECK GLASS HATCH SWITCH
1. Turn ignition switch OFF.
2. Insure front door lock actuator RH is in the unlock position.
3. Check continuity between glass hatch switch terminal 2 and ground.
Is the inspection result normal?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK HARNESS CONTINUITY
1. Disconnect glass hatch switch.
2. Disconnect BCM.
3. Check continuity between BCM connector M18 (A) terminal 30 and glass hatch switch connector D706 (B) terminal 2.
4. Check continuity between BCM connector M18 (A) terminal 30 and ground.
Is the inspection result normal?
YES >> Glass hatch switch circuit is OK.
NO >> Repair or replace harness.
3.CHECK GLASS HATCH SWITCH
1. Disconnect glass hatch switch.
2. Check continuity between glass hatch switch harness connector D706 terminal 1 and ground.
Is the inspection result normal?
YES >> Replace glass hatch switch.
NO >> GO TO 4.
4.CHECK HARNESS CONTINUITY
Connec- tor Te r m i n a l s
ConditionContinuity
(+) (–)
D706 2 Ground With the glass hatch switch
pressed
Ye s
With the glass hatch switch
released No
LIIA2399E
30 - 2
: Continuity should exist.
30 - Ground : Continuity should not exist.
LIIA2400E
1 - Ground: Continuity should exist.
LIIA2401E
Revision: April 20092010 QX56

Page 962 of 4210

DLK-128
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
GLASS HATCH SWITCH
1. Disconnect front door lock actuator RH.
2. Check continuity between glass hatch switch connector D706
(A) terminal 1 and front door lock actuator RH connector D114
(B) terminal 4
Is the inspection result normal?
YES >> GO TO 5.
NO >> Repair or replace harness.
5.CHECK FRONT DOOR LOCK ACTUATOR RH GROUND CIRCUIT
Check continuity between front door lock actuator RH connector
D114 terminal 5 and ground
Is the inspection result normal?
YES >> Replace front door lock actuator RH. Refer to DLK-242,
"Removal and Installation".
NO >> Repair or replace harness. 1 - 4 : Continuity should exist.
LIIA2402E
5 - Ground
: Continuity should exist.
LIIA2403E
Revision: April 20092010 QX56

Page 963 of 4210

GLASS HATCH AJAR SWITCHDLK-129
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
GLASS HATCH AJAR SWITCH
Diagnosis ProcedureINFOID:0000000005147000
Regarding Wiring Diagram information, refer to DLK-199, "Wiring Diagram—AUTOMATIC BACK DOOR SYS-
TEM—".
1.CHECK GLASS HATCH AJAR SWITCH INPUT SIGNAL
With CONSULT-III
Check glass hatch ajar switch ("TRNK OPN MNTR") in DATA MONITOR mode with CONSULT–III.
• When glass hatch is open:
• When glass hatch is closed:
Without CONSULT-III
Check voltage between BCM connector M19 terminal 42 and ground.
Is the inspection result normal?
YES >> System is OK.
NO >> GO TO 2
2.CHECK GLASS HATCH AJAR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect glass hatch ajar switch, BCM and back door control unit.
3. Check continuity between BCM connector (A) M19 te rminal 42 and glass hatch ajar switch connector (C)
D707 terminal 1.
4. Check continuity between back door control unit connector B55
(B) terminal 17 and glass hatch ajar switch connector (C) D707
terminal 1.
5. Check continuity between glass hatch ajar switch connector (C) D707 terminal 1 and ground.
Is the inspection result normal?
YES >> GO TO 3
NO >> Repair or replace harness.
3.CHECK GLASS HATCH AJAR SWITCH
1. Disconnect glass hatch ajar switch connector. TRNK OPN MNTR : ON
TRNK OPN MNTR : OFF
Connector Item
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M19 BCM 42 Ground Open

Closed 0

Battery voltage
LIIA1149E
42 - 1 : Continuity should exist.
17 - 1 : Continuity should exist.
1 - Ground : Continuity should not exist.
ALKIA0667ZZ
Revision: April 20092010 QX56

Page 964 of 4210

DLK-130
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
GLASS HATCH AJAR SWITCH
2. Check continuity between glass hatch ajar switch connector terminal 1 and ground.
Is the inspection result normal?
YES >> Check glass hatch ajar switch case ground condition.
NO >> Replace glass hatch ajar s
witch, or repair or replace
harness.
Terminals Condition Continuity
Glass hatch ajar switch 1 – Ground Open
Yes
Closed No
ALKIA0668ZZ
Revision: April 20092010 QX56

Page 965 of 4210

BACK DOOR CLOSE (CLOSE) SWITCH SYSTEM
DLK-131
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
BACK DOOR CLOSE (C LOSE) SWITCH SYSTEM
Diagnosis ProcedureINFOID:0000000005147001
Regarding Wiring Diagram information, refer to DLK-199, "Wiring Diagram—AUTOMATIC BACK DOOR SYS-
TEM—".
1.BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (close) s witch using switch operation.
Is the inspection result normal?
YES >> Back door close switch is OK.
NO >> GO TO 2
2.BACK DOOR CLOSE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close switch, check voltage between back door control unit connector B55 terminal 8 and
ground.
Is the inspection result normal?
YES >> Switch is OK.
NO >> GO TO 3
3.BACK DOOR CLOSE SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door control unit connector (A) B55 terminal 8 and back door close switch connector (B) B63
terminal 1.
3. Check continuity between back door control unit connector (A) B55 terminal 8 and ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair the harness between the back door close switch and the back door control unit.
4.BACK DOOR CLOSE SWITCH GROUND INSPECTION
Te r m i n a l s
Measuring condition Voltage (V)
(Approx.)
(+) (-)
8G ro u nd Back door
close switch ON
0
OFF Battery voltage
LIIA0805E
8 - 1 : Continuity should exist.
8 - Ground : Continuity should not exist.
ALKIA0669ZZ
Revision: April 20092010 QX56

Page 966 of 4210

DLK-132
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
BACK DOOR CLOSE (CLOSE) SWITCH SYSTEM
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
Is the inspection result normal?
YES >> Replace the back door close switch.
NO >> Repair the harness between the back door close switch
and ground.
3 - Ground : Continuity should exist.
WIIA0602E
Revision: April 20092010 QX56

Page 967 of 4210

BACK DOOR CLOSE (CANCEL) SWITCH SYSTEMDLK-133
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
BACK DOOR CLOSE (CANCEL) SWITCH SYSTEM
Diagnosis ProcedureINFOID:0000000005147002
Regarding Wiring Diagram information, refer to DLK-199, "Wiring Diagram—AUTOMATIC BACK DOOR SYS-
TEM—".
1.BACK DOOR CLOSE SWITCH FUNCTION INSPECTION
Check back door close (cancel) s witch using switch operation.
Is the inspection result normal?
YES >> Back door close switch is OK.
NO >> GO TO 2
2.BACK DOOR CLOSE (CANCEL) SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the back door close (cancel) switch, check volt- age between back door control uni t connector B55 terminal 13
and ground.
Is the inspection result normal?
YES >> Switch is OK.
NO >> GO TO 3
3.BACK DOOR CLOSE (CANCEL) SWITCH CIRCUIT INSPECTION
1. Disconnect back door close switch and back door control unit connector.
2. Check continuity between back door control unit connector (A) B55 terminal 13 and back door close switch connector (B) B63
terminal 5.
3. Check continuity between back door control unit connector (A) B55 terminal 13 and ground.
Is the inspection result normal?
YES >> GO TO 4
NO >> Repair the harness between the back door close switch and the back door control unit.
4.BACK DOOR CLOSE SWITCH GROUND INSPECTION
Te r m i n a l s
Measuring condition Voltage (V)
(Approx.)
(+) (-)
13 Ground Back door
close switch ON
0
OFF 5
LIIA1068E
13 - 5 : Continuity should exist.
13 - Ground : Continuity should not exist.
ALKIA0671ZZ
Revision: April 20092010 QX56

Page 968 of 4210

DLK-134
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
BACK DOOR CLOSE (CANCEL) SWITCH SYSTEM
Check continuity between back door close switch connector B63 ter-
minal 3 and ground.
Is the inspection result normal?
YES >> Replace the back door close switch.
NO >> Repair the harness between the back door close switch
and ground.
3 - Ground : Continuity should exist.
WIIA0602E
Revision: April 20092010 QX56

Page 969 of 4210

PINCH STRIP SYSTEMDLK-135
< COMPONENT DIAGNOSIS > [WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G H
I
J
L
M A
B
DLK
N
O P
PINCH STRIP SYSTEM
Diagnosis ProcedureINFOID:0000000005147003
Regarding Wiring Diagram information, refer to DLK-199, "Wiring Diagram—AUTOMATIC BACK DOOR SYS-
TEM—".
1.PINCH STRIP SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the pinch strip, check voltage between back door control unit connector B55 terminals 19, 20 and ground.
Is the inspection result normal?
YES >> Switch is OK.
NO >> GO TO 2
2.PINCH STRIP CIRCUIT INSPECTION
1. Disconnect pinch strip and ba ck door control unit connector.
2. Check continuity between back door control unit connector (A) B55 terminals 5, 19 (RH) or 5, 20 (LH) and pinch strip connector
(B) D715 (RH), D517 (LH) terminals 1, 2.
3. Check continuity between pinch strip connector (B) D715 (RH), D517 (LH) terminals 1, 2 and ground.
Is the inspection result normal?
YES >> Replace the pinch strip.
NO >> Repair the harness between the pinc h strip and the back door control unit.
Te r m i n a l s
Measuring condition Voltage (V)
(Approx.)
(+) (-)
19 Ground Pinch strip RH operation 0
Other 4
20 Ground Pinch strip LH operation 0
Other 4
LIIA0811E
RH: 1 - 19 : Continuity should exist.
LH: 1 - 20 : Continuity should exist.
RH and LH 2 - 5 : Continuity should exist.
1 - Ground : Continuity should not exist.
2 - Ground : Continuity should not exist.
ALKIA0672ZZ
Revision: April 20092010 QX56

Page 970 of 4210

DLK-136
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
BACK DOOR WARNING CHIME SYSTEM
BACK DOOR WARN
ING CHIME SYSTEM
Diagnosis ProcedureINFOID:0000000005147004
Regarding Wiring Diagram information, refer to DLK-199, "Wiring Diagram—AUTOMATIC BACK DOOR SYS-
TEM—".
1.BACK DOOR WARNING CHIME CIRCUIT INSPECTION
1. Disconnect back door control unit and back door warning chime.
2. Check continuity between back door control unit connector (A) B55 terminal 6 and back door warning chime connector (B)
D514 terminal 1.
3. Check continuity between back door control unit connector (A) B55 terminal 6 and ground.
Is the inspection result normal?
YES >> GO TO 2
NO >> Repair or replace the harness between t he warning chime and the back door control unit.
2.WARNING CHIME CIRCUIT INSPECTION
1. Check continuity between back door control unit connector (A) B55 terminal 9 and back door warning chime connector (B)
D514 terminal 2.
2. Check continuity between back door control unit connector (A) B55 terminal 9 and ground.
Is the inspection result normal?
YES >> Replace warning chime.
NO >> Repair or replace the harness between t he warning chime and the back door control unit.
6 - 1 : Continuity should exist.
6 - Ground : Continuity should not exist.
ALKIA0673ZZ
9 - 2
: Continuity should exist.
9 - Ground : Continuity should not exist.
ALKIA0674ZZ
Revision: April 20092010 QX56